Description
Pentair Water® offers a full range of Autotrol® Control Valves to meet a wide range of water conditioning applications.
742 Time Clock
- Simple, economic electronic time clock (chronometric)
- 7- or 99-day regeneration setting
- 12-volt operation
- Filter or conditioner setting in one control
- Fully programmable cycle times
- Salt setting in 1-pound increments
- Operates 255, 263, 268, 273, 278, and Magnum® IT with one controller
Models
Logix™ Series
Electrical
- Controller Operating Voltage 12 Volt – AC (Requires use of Pentair Water®-supplied transformer)
- Input Supply Frequency 50 or 60 Hz (Controller configuration dependent)
- Motor Input Voltage 12 Volt – AC
- Controller System Power Consumption 3 Watts average
Design Specifications/Ratings
- Valve Body Glass-filled thermoplastic – NSF Listed material
- Rubber Components Compounded for cold water – NSF Listed material
- Valve Materials Certification WQA Gold Seal Certified to ORD0902 and
- NSF/ANSI 44 Rated component for material safety
- Weight (Valve with Control) 5.34 Ibs (2.42 kg)
- Recommended Operating Pressure 20 – 120 psi (1.38 – 8.27 bar)
- Canada 20 – 100 psi (1.38 – 6.89 bar)
- Hydrostatic Test Pressure 300 psi (20.69 bar)
- Water Temperature 35° – 100°F (2° – 38°C)
- Ambient Temperature* 35° – 120°F (2° – 48.9°C)
*Recommend use of outdoor cover for direct sunlight applications.
Features
Standard Features
- Regenerate up to 7 cu. ft. of softener resin
- Performa means performance – large 1″ ports for high-flow applications
- Valve quickly changes from softener to filter application in three easy steps
- Designed with fewer service parts than any valve of comparable function – longer life, shorter service calls
- Bypass attachment makes maintenance exceptionally fast
Applications
Options
- Filter or softener control valves
- Fiber-reinforced polymer bypass valve
- Plumbing connections in .75″-1.25″ NPT, BSP, and sweat
- Internal Autotrol turbine
- Variable reserve for increased efficiency
- Auxiliary switch kits
- Timer wall mount kits
- 742– Professional level time clock control with fully programmable cycle times and salt amount.
- 762– Professional level metered control with fully programmable cycle times and salt amount.
- 764– Professional level metered control with fully programmable cycle times and salt amount for multiple tank applications.