<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Signet Instruments &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/signet-instruments/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:51:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Signet 2850 Sensor Electronics</title>
		<link>https://aquacomponents.sa/product/signet-2850-sensor-electronics/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:51:02 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2850-sensor-electronics/</guid>

					<description><![CDATA[Signet 2850 Sensor Electronics provide a variety of implementations in order to guarantee the ideal flexibility during installation. There is a complete mounting version for tank, pipe, and well mounting, including single or dual options utilizing all kinds of conventional Signet resistivity and conductivity sensors, thereby requiring only one instrument for multple sensor types.&#160; Models [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 2850 Sensor Electronics provide a variety of implementations in order to guarantee the ideal flexibility during installation. There is a complete mounting version for tank, pipe, and well mounting, including single or dual options utilizing all kinds of conventional Signet resistivity and conductivity sensors, thereby requiring only one instrument for multple sensor types.&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>Signet 2850 Sensor Electronics Specifications:</strong></p>
<table class="tableCenter" style="height: 400px; width: 1173px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1168.92px;" colspan="7"><strong>General</strong><strong><br /></strong></th>
</tr>
<tr style="height: 10px;">
<th style="text-align: center; width: 224.375px; height: 10px;">
<p>Compatible Electrodes&nbsp;&nbsp;</p>
</th>
<th style="text-align: center; height: 10px; width: 942.557px;" colspan="6">All Signet Sensors</th>
</tr>
<tr style="height: 46px;">
<th style="text-align: center; width: 1168.92px; height: 46px;" colspan="7">
<p>Materials</p>
</th>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; height: 10px; width: 224.375px;">
<p>NPT Mount Junction Box for Integral Mount&nbsp;&nbsp;</p>
</th>
<th style="text-align: center; height: 10px; width: 942.557px;" colspan="6">PBT</th>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; width: 224.375px; height: 46px;">
<p>Universal/Remote Mount&nbsp;&nbsp;</p>
</th>
<th style="text-align: center; height: 46px; width: 942.557px;" colspan="6">
<p>PBT, CPVC</p>
</th>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; height: 12px; width: 1168.92px;" colspan="7">EasyCal &#8211; Automatic Recognition of the Following Conductivity Values</th>
</tr>
<tr style="height: 61px;">
<th style="text-align: center; width: 224.375px; height: 140px;" rowspan="2">&nbsp;</th>
<th style="text-align: center; width: 942.557px; height: 61px;" colspan="6">146.93 &micro;S, 1408.8 &micro;S, 12856 &micro;S (@25 &deg;C) (Test solutions Per ASTM D1125-95)</th>
</tr>
<tr style="height: 79px;">
<th style="text-align: center; width: 942.557px; height: 79px;" colspan="6">10 &micro;S, 100 &micro;S, 200 &micro;S, 500 &micro;S, 1000 &micro;S, 5000 &micro;S, 10,000 &micro;S, 50,000 &micro;S, 100,000 &micro;S <br />(@ 25 &deg;C) (Standard test solutions)</th>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify"></p>
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Test certificate supplied with all sensors</li>
<li>Custom cell constant programmed into the electronics</li>
<li>Integral mount systems for quick and easy installation</li>
<li>Compact design for maximum installation flexibility</li>
<li>Extends the disctance between the measuring point and the 9900 Transmitter to 120 m (400 ft)</li>
<li>Digital (S3L) interface or two-wire 4 to 20 mA output</li>
<li>EasyCal with automatic test solution</li>
<li>Dual channel unit available for low cost installation with Signet 8900 Multi-Parameter Controller</li>
<li>For use with ALL Signet conductivity electrodes</li>
</ul>
<p align="justify">&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Water Treatment and Water Quality Monitoring</li>
<li>Reverse Osmosis</li>
<li>Deionization</li>
<li>Demineralization, Regeneration and Rinse</li>
<li>Scrubber</li>
<li>Cooling Tower and Boiler Protection</li>
<li>Aquatic Animal Life Support Systems</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 2850 Sensor Electronics" href="../../../../content/pdf/signet-2850-conductivity-resistivity-sensor-pvdf-version.pdf" target=" _blank">Signet 2850 Sensor Electronics Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 2350 Temperature Sensor</title>
		<link>https://aquacomponents.sa/product/signet-2350-temperature-sensor/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:13 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2350-temperature-sensor/</guid>

					<description><![CDATA[Signet 2350 Temperature Sensor deliver advanced features that are optimal for utilization in high water purity applications, and provide better instruments than metal sensors in vigorous liquids. Thermowells are not required when using these instruments which works in saving expenses. A compact assembly of field-operated mounting versions is achieved with integral adapter kits.&#160; Models Signet [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 2350 Temperature Sensor deliver advanced features that are optimal for utilization in high water purity applications, and provide better instruments than metal sensors in vigorous liquids. Thermowells are not required when using these instruments which works in saving expenses. A compact assembly of field-operated mounting versions is achieved with integral adapter kits.&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Signet 2350 Temperature Sensor Specifications:</strong></h5>
<table class="tableCenter" style="height: 377px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1057.1px;" colspan="5"><strong>General</strong><strong><br /></strong></th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; height: 36px; width: 238.011px;">Output</th>
<td style="text-align: center; height: 36px; width: 817.102px;" colspan="4">Digital (S3 L) output or 4 to 20 mA</td>
</tr>
<tr style="height: 55px;">
<th style="text-align: center; width: 238.011px; height: 55px;">Accuracy</th>
<td style="text-align: center; height: 55px; width: 817.102px;" colspan="4">&plusmn;0.5 &deg;C (&plusmn;0.9 &deg;F)</td>
</tr>
<tr style="height: 55px;">
<th style="text-align: center; width: 238.011px; height: 55px;">Response Time, <i>t</i></th>
<td style="text-align: center; height: 55px; width: 817.102px;" colspan="4">10 secs.</td>
</tr>
<tr style="height: 55px;">
<th style="text-align: center; width: 238.011px; height: 55px;">Repeatability</th>
<td style="text-align: center; height: 55px; width: 817.102px;" colspan="4">&plusmn;0.1 &deg;C (&plusmn;0.2 &deg;F)</td>
</tr>
<tr style="height: 55px;">
<th style="text-align: center; width: 238.011px; height: 55px;">Resolution</th>
<td style="text-align: center; height: 55px; width: 817.102px;" colspan="4">0.01 &deg;C (0.02 &deg;F)</td>
</tr>
<tr style="height: 56px;">
<th style="text-align: center; width: 238.011px; height: 56px;">Sensing-End Connection</th>
<td style="text-align: center; height: 56px; width: 817.102px;" colspan="4">&frac34; in. NPT male thread</td>
</tr>
<tr style="height: 51px;">
<th style="text-align: center; width: 238.011px; height: 51px;">Cable-End Connection</th>
<td style="text-align: center; width: 817.102px; height: 51px;" colspan="4">&frac34; in. NPT male thread</td>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Plating Bath Temperature Control</li>
<li>Heat Exchange Monitor</li>
<li>RO and DI System Monitor</li>
<li>Hot and Cold Mixing System Monitor</li>
<li>Data Acquisition</li>
<li>Cooling Loops</li>
<li>Effluent Monitoring</li>
<li>HVAC</li>
<li>Chemical Processing</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>4 to 20 mA output or digital (S3L) output</li>
<li>One-piece injection-molded SYGEF&reg; PVDF body</li>
<li>PT1000 Platinum RTD in extended tip for quick response</li>
<li>Threaded for in-line or submersible installation</li>
<li>Standard &frac34;&#8221; in. NPT process connection&nbsp;&nbsp;</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 2350 Temperature Sensor" href="../../../../content/pdf/signet-2350-temperature-sensor.pdf" target=" _blank">Signet 2350 Temperature Sensor Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 2450 Pressure Sensor</title>
		<link>https://aquacomponents.sa/product/signet-2450-pressure-sensor/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:12 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2450-pressure-sensor/</guid>

					<description><![CDATA[Signet 2450 Pressure Sensor include the appropriate features to meet your sensing requirements, including adding a temperature compensation function that enhances accuracy over different temperature ranges. Such instruments also address issues with corrosion under harsh conditions and chemical compatability. Models Signet 2450 Pressure Sensor Specifications: General Output Digital (S3 L) or 4 to 20 mA [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span class="nd-word"><span>Signet 2450 Pressure Sensor include the appropriate features to meet your sensing requirements, including adding a temperature compensation function that enhances accuracy over different temperature ranges. Such instruments also address issues with corrosion under harsh conditions and chemical compatability.</span></span></p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Signet 2450 Pressure Sensor Specifications:</strong></h5>
<table class="tableCenter" style="height: 207px;" width="1137" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1132.56px;" colspan="8"><strong>General</strong><strong><br /></strong></th>
</tr>
<tr style="height: 24px;">
<th style="height: 29px; width: 247.102px;" align="left">Output</th>
<td style="text-align: left; height: 29px; width: 883.466px;" colspan="7">Digital (S3 L) or 4 to 20 mA</td>
</tr>
<tr style="height: 16px;">
<th style="height: 22px; width: 1132.56px;" colspan="8" align="left">Accuracy</th>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; width: 247.102px; height: 115px;" rowspan="3">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</th>
<td style="text-align: center; height: 32px; width: 398.92px;" colspan="2">For all pressure ranges</td>
<td style="text-align: center; height: 32px; width: 482.557px;" colspan="5">&plusmn;1% of full scale @ 25 &deg;C</td>
</tr>
<tr style="height: 30px;">
<td style="text-align: center; height: 36px; width: 398.92px;" colspan="2">Response Time</td>
<td style="text-align: center; height: 36px; width: 482.557px;" colspan="5">&lt; 100 ms</td>
</tr>
<tr style="height: 47px;">
<td style="text-align: center; width: 398.92px; height: 47px;" colspan="2">Sensing-End Connection</td>
<td style="text-align: center; width: 482.557px; height: 47px;" colspan="5">&frac12; in. union male thread (requires end connector and union nut)</td>
</tr>
<tr style="height: 25px;">
<th style="height: 27px; width: 247.102px;" align="left">Cable-end connection</th>
<td style="width: 883.466px; height: 27px;" colspan="5">&frac34; in. NPT male thread</td>
</tr>
</tbody>
</table>
<p align="justify">
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Test certificate included</li>
<li>4 to 20 mA output or digital (S3L) output</li>
<li>1/2 in. male union process connection</li>
<li>One-piece injection-molded PVDF body</li>
<li>Flush ceramic diaphragm</li>
<li>Easy installation</li>
<li>Choice of three pressure ranges</li>
<li>Pressure or level measurement</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Level or Depth Sensing</li>
<li>HVAC</li>
<li>Scrubber Systems</li>
<li>Pump Protection</li>
<li>Water Management</li>
<li>Irrigation Systems</li>
<li>Wastewater</li>
<li>Chemical Processing</li>
<li>Pressure Regulation/Monitoring&nbsp; &nbsp;</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document"><a title="Signet 2450 Pressure Sensor" href="../../../../content/pdf/signet-2450-pressure-sensors.pdf" target=" _blank">Signet 2450 Pressure Sensor Data Sheet</a></p></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 2818-2823 Electrodes</title>
		<link>https://aquacomponents.sa/product/signet-2818-2823-electrodes/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:10 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2818-2823-electrodes/</guid>

					<description><![CDATA[Signet 2818-2823 Electrodes are designed for maximum verstaility during installation and precise sensing for an extremely great range. Materials are added to ensure other ideal features such as fantastic chemical compatibility and a surface finish to improve repeatability and accuracy. Models Signet 2818-2823 Electrodes Specifications: General Operating Range 3-2818, 3-2819 0.055 to 100 &#181;S 18.2 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 2818-2823 Electrodes are designed for maximum verstaility during installation and precise sensing for an extremely great range. Materials are added to ensure other ideal features such as fantastic chemical compatibility and a surface finish to improve repeatability and accuracy.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>Signet 2818-2823 Electrodes Specifications:</strong></p>
<table class="tableCenter" style="height: 350px; width: 1176px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1171.65px;" colspan="7"><strong>General</strong><strong><br /></strong></th>
</tr>
<tr>
<th style="text-align: center; width: 179.83px;">
<p>Operating Range</p>
</th>
<th style="text-align: center; width: 134.375px;" colspan="2">3-2818, 3-2819</th>
<th style="text-align: center; width: 240.739px;" colspan="2">0.055 to 100 &micro;S</th>
<th style="text-align: center; width: 146.193px;">18.2 M&Omega; to 10 K&Omega;</th>
<th style="text-align: center; width: 462.557px;">0.02 to 50 ppm</th>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; width: 179.83px; height: 42px;" rowspan="2">
<p>&nbsp;</p>
<p>&nbsp;</p>
</th>
<th style="text-align: center; height: 32px; width: 134.375px;" colspan="2">3-2820</th>
<th style="text-align: center; height: 32px; width: 240.739px;" colspan="2">1 to 1000 &micro;S</th>
<th style="text-align: center; width: 146.193px;">1 M&Omega; to 1 K&Omega;</th>
<th style="text-align: center; width: 462.557px;">0.5 to 500 ppm</th>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; height: 10px; width: 134.375px;" colspan="2">3-2821</th>
<th style="text-align: center; height: 10px; width: 240.739px;" colspan="2">10 to 10,000 &micro;S</th>
<th style="text-align: center; width: 610.739px;" colspan="2">5 to 5,000 ppm</th>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; height: 12px; width: 179.83px;">Cell Constant Accuracy</th>
<th style="text-align: center; width: 989.83px;" colspan="6">&plusmn;2% of reading (certified cells &plusmn;1%)</th>
</tr>
<tr>
<th style="text-align: center; width: 558.92px;" colspan="5">Temperature Compensation Device</th>
<th style="text-align: center; width: 610.739px;" colspan="2">Pt1000</th>
</tr>
<tr>
<th style="text-align: center; width: 179.83px;" rowspan="2">Cable Length (use for the 2818, 19, 20, 21, 22 and 23)</th>
<th style="text-align: center; width: 133.466px;">Standard</th>
<th style="text-align: center; width: 854.375px;" colspan="5">4.6 m (15 ft)</th>
</tr>
<tr>
<th style="text-align: center; width: 133.466px;">Maximum</th>
<th style="text-align: center; width: 854.375px;" colspan="5">30 m (100 ft) all sensors when used with 9900 or 9950 and Direct Conductivity/ <br />Resistivity Module. 2818, 2819 maximum 4.6 m (15 ft) when used with 2850</th>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>In-line or submersible mounting</li>
<li>NIST traceable certified cells &plusmn;1% meet USP requirements</li>
<li>Standard process connections &frac34;&#8221; NPT Polypro</li>
<li>Tri-clamp 1 -1 1/2&#8243;, 2&#8243;</li>
<li>&frac34; in. NPT SS on 10 and 20 cell</li>
<li>Optional 1/2&#8243; NPT 316 SS</li>
<li>316 SS or Titanium standard electrode</li>
<li>Alternative electrode materials available</li>
<li>Hastelloy-C</li>
<li>Monel</li>
<li>Titanium</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Pure Water Treatment: Reverse Osmosis, Deionization, Distillation</li>
<li>Boiler condensate</li>
<li>Semiconductor Water Production</li>
<li>Rinse Water Monitoring and Control</li>
<li>Chemical Concentrations</li>
<li>Cleaner and Degreaser Concentrations</li>
<li>TDS (total dissolved solids)</li>
<li>Salinity</li>
<li>USP Purified Water</li>
<li>WFI Water Production</li>
<li>Ultra Pure Water</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 2818-2823 Electrodes" href="../../../../content/pdf/signet-2818-2823-conductivity-resistivity-electrodes.pdf" target=" _blank">Signet 2818-2823 Electrodes Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 2734-2736 pH/ORP Electrodes</title>
		<link>https://aquacomponents.sa/product/signet-2734-2736-ph-orp-electrodes/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:09 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2734-2736-ph-orp-electrodes/</guid>

					<description><![CDATA[Signet 2734-2736 pH/ORP Electrodes provides the perfect range for a great deal of harsh utilizations that conssit of minimal concentrations of chemicals and harmful ions reaction with silver minerals, Ag+. Chemical resistance is ensured through an advanced glass formulation when exposed to adverse environments. Long-life use, improved efficiency, protection against coating are other added features [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 2734-2736 pH/ORP Electrodes provides the perfect range for a great deal of harsh utilizations that conssit of minimal concentrations of chemicals and harmful ions reaction with silver minerals, Ag+. Chemical resistance is ensured through an advanced glass formulation when exposed to adverse environments. Long-life use, improved efficiency, protection against coating are other added features incorporated within these instruments.&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>Signet 2734-2726 pH/ORP Electrodes Specifications:</strong></p>
<table class="tableCenter" style="height: 398px; width: 1169px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1164.38px;" colspan="5"><strong>General</strong></th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; height: 36px; width: 236.193px;">Performance</th>
<td style="text-align: center; height: 36px; width: 499.83px;" colspan="2">Efficiency</td>
<td style="text-align: center; width: 424.375px; height: 36px;" colspan="2">&gt;95% @ 25 &deg;C (77 &deg; F)</td>
</tr>
<tr>
<th style="width: 236.193px;">Operating Range</th>
<td style="text-align: center; width: 499.83px;" colspan="2">pH</td>
<td style="text-align: center; width: 424.375px;" colspan="2">0 to 14 pH</td>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; width: 236.193px; height: 42px;" rowspan="2">
<p>&nbsp;</p>
<p>&nbsp;</p>
</th>
<td style="text-align: center; height: 32px; width: 499.83px;" colspan="2">ORP</td>
<td style="text-align: center; width: 424.375px; height: 32px;" colspan="2">&plusmn;2000 mV</td>
</tr>
<tr>
<td style="text-align: center; width: 499.83px;" colspan="2">3-2734-HF, 3-2736-HF</td>
<td style="text-align: center; width: 424.375px;" colspan="2">Hydrofl uoric acid resistant glass, pH 6 or below; trace HF &lt;2%</td>
</tr>
<tr style="height: 25px;">
<th style="width: 1164.38px;" colspan="5" align="left">Compatability</th>
</tr>
<tr>
<th style="text-align: center; width: 236.193px;">&nbsp;</th>
<td style="text-align: center; width: 926.193px;" colspan="4">2751 pH/ORP Smart Sensor Electronics (for 8900, 9900, 9950 , Profi bus Concentrator, 4 to 20 mA)</td>
</tr>
<tr>
<th style="width: 1164.38px;" colspan="5" align="left">Temperature Sensor</th>
</tr>
<tr>
<th style="text-align: center; width: 236.193px;">&nbsp;</th>
<td style="text-align: center; width: 272.557px;">Pt1000 versions</td>
<td style="text-align: center; width: 651.648px;" colspan="3">Compatible with Signet 2751 pH/ORP Smart Sensor Electronics for connection to a PLC or to the Signet 8900, 9900 or 9950 instruments and 0486 Profi bus Concentrator</td>
</tr>
<tr>
<th style="width: 1164.38px;" colspan="5" align="justify">Process Connection</th>
</tr>
<tr>
<th style="text-align: center; width: 236.193px;">&nbsp;</th>
<td style="text-align: center; width: 272.557px;">&frac34; in. NPT</td>
<td style="text-align: center; width: 225.284px;">ISO 7/1-R 3/4</td>
<td style="text-align: center; width: 424.375px;" colspan="2">Mounts into Signet fittings</td>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Enhanced reference chemistry to resist chemical poisoning and prolong the life of the electrodes in harsh environments</li>
<li>PTFE reference junction resists fouling and chemical attack</li>
<li>Superior pH glass formulation for excellent chemical resistance in acidic and alkaline/caustic environments</li>
<li>Ryton&reg; (PPS) body for broad range of chemical compatibility</li>
<li>Memory chip enabled for access to a range of unique features when connected to the Signet 2751 pH/ORP Smart Sensor Electronics</li>
<li>Patented reference design for exceptional performance</li>
<li>Patented DryLoc&reg; connector with gold plated contacts</li>
<li>Mounts in Signet standard fittings from DN15 to DN100 (&frac12; to 4 in.) or standard pipe fitting, 3/4&#8243; NPT or ISO 7/1-R 3/4</li>
<li>Special design allows for installation at any angle, even inverted or horizontal</li>
<li>Quick temperature response</li>
<li>Bulb and flat HF resistant glass available for trace HF, in less than 2% concentration applications</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Wastewater Treatment</li>
<li>Reverse Osmosis</li>
<li>Deionization</li>
<li>Chemical Manufacturing/Addition</li>
<li>Metal and Plastic Finishing</li>
<li>Fume Scrubbers</li>
<li>Cooling Towers</li>
<li>Media Filtration</li>
<li>Chemical Dosing/Injection</li>
<li>Aquatic Life Support</li>
<li>Pools &amp; Fountains</li>
<li>Rinse Tanks</li>
<li>Chemical Neutralization&nbsp;</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 2734-2736 pH/ORP Electrodes" href="../../../../content/pdf/signet-2734-2736-ph-and-orp-electrodes.pdf" target=" _blank">Signet 2734-2736 pH/ORP Electrodes Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 2724-2726 pH/ORP Electrodes</title>
		<link>https://aquacomponents.sa/product/signet-2724-2726-ph-orp-electrodes/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:08 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-2724-2726-ph-orp-electrodes/</guid>

					<description><![CDATA[Signet 2724-2726 pH/ORP Electrodes are multi-purpose sensor instruments that capable of being utilized across all sorts of applications. The advanced features incorporated in these products are fouling-resistant and are sure to elevate the overall efficiency and durability of the system. Resistance to corrosion under harsh environments further makes these instruments adaptable to specific utilizations that [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 2724-2726 pH/ORP Electrodes are multi-purpose sensor instruments that capable of being utilized across all sorts of applications. The advanced features incorporated in these products are fouling-resistant and are sure to elevate the overall efficiency and durability of the system. Resistance to corrosion under harsh environments further makes these instruments adaptable to specific utilizations that other related items could not operate in.&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>Signet 2724-2726 pH/ORP Electrodes Specifications:</strong></p>
<table class="tableCenter" style="height: 404px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1154.38px;" colspan="5"><strong>General</strong></th>
</tr>
<tr style="height: 36px;">
<th style="width: 237.102px;">Performance</th>
<td style="text-align: center; height: 36px; width: 399.83px;" colspan="2">Efficiency</td>
<td style="text-align: center; width: 513.466px; height: 36px;" colspan="2">&gt;97% @ 25 &deg;C (77 &deg; F)</td>
</tr>
<tr style="height: 46px;">
<th style="width: 237.102px;">Operating Range</th>
<td style="text-align: center; width: 399.83px; height: 46px;" colspan="2">pH</td>
<th style="text-align: center; width: 513.466px; height: 46px;" colspan="2">0 to 14 pH</th>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; width: 237.102px; height: 88px;" rowspan="3">
<p>&nbsp;</p>
<p>&nbsp;</p>
</th>
<td style="text-align: center; height: 32px; width: 399.83px;" colspan="2">ORP</td>
<td style="text-align: center; width: 513.466px; height: 32px;" colspan="2">&plusmn;2000 mV</td>
</tr>
<tr style="height: 30px;">
<td style="text-align: center; height: 10px; width: 399.83px;" colspan="2">3-2726-LC</td>
<td style="text-align: center; height: 10px; width: 513.466px;" colspan="2">Low conductivity fluids; 20 &#8211; 100 &micro;S/cm nominal &lt; 20 &micro;S; flow must be less than 150 ml/min in a properly grounded system</td>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; width: 399.83px; height: 46px;" colspan="2">3-2724-HF, 3-2726-HF</td>
<td style="text-align: center; width: 513.466px; height: 46px;" colspan="2">Hydrofluoric acid resistant glass, pH 6 or below; trace HF &lt;2%</td>
</tr>
<tr>
<td style="width: 1154.38px;" colspan="5"><strong>Compatability</strong></td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; width: 237.102px; height: 18px;">&nbsp;</td>
<td style="text-align: center; width: 915.284px; height: 18px;" colspan="4">2751 Smart Sensor Electronics (for 8900, 9900, 9950, 4 to 20 mA or Profi bus Concentrator), 2760 Preamplifier</td>
</tr>
<tr>
<th style="width: 1154.38px;" colspan="5" align="left">Temperature Sensor</th>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 237.102px; height: 72px;" rowspan="2">&nbsp;</td>
<td style="text-align: center; width: 272.557px; height: 36px;">Pt1000 versions</td>
<td style="text-align: center; width: 640.739px; height: 36px;" colspan="3">Compatible with Signet 2751 pH/ORP Smart Sensor Electronics for connection to a PLC or to the Signet 8900, 9900 or 9950 instruments</td>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 272.557px; height: 36px;">3 KO Balco versions</td>
<td style="text-align: center; width: 640.739px; height: 36px;" colspan="3">Compatible with Signet 2751 pH/ORP Smart Sensor Electronics or with Signet 2760 pH/ORP Preamplifier for connection to the Signet 8750 pH/ORP Transmitter</td>
</tr>
<tr>
<th style="width: 1154.38px;" colspan="5" align="left">Process Connection</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; width: 237.102px; height: 18px;">&nbsp;</th>
<td style="text-align: center; width: 272.557px; height: 18px;">&frac34; in. NPT&nbsp; &nbsp;</td>
<td style="text-align: center; width: 125.284px; height: 18px;">ISO 7/1-R 3/4</td>
<td style="text-align: center; width: 513.466px; height: 18px;" colspan="2">Mounts into Signet fittings</td>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Patented reference design for exceptional performance and prolonged life in harsh environments Memory chip enabled for access to a wide range of unique features when connected to theSignet 2751 pH/ORP Smart Sensor Electronics</li>
<li>Ryton&reg; (PPS) body for broad range of chemical compatibility</li>
<li>Patented DryLoc&reg; connector with gold plated contacts</li>
<li>Special design allows for installation at any angle, even inverted or horizontal</li>
<li>&frac34;&rdquo; NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees DN15 to DN100 (&frac12; to 4 in.)</li>
<li>Mounts in Signet standard fittings from DN15 to DN100 (&frac12; to 4 in.)</li>
<li>Quick temperature response</li>
<li>Bulb and flat HF resistant glass available for trace HF, in less than 2% concentration applications</li>
<li>Low conductivity sensor available for liquids down to 20 &micro;S/cm</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Water and Wastewater Treatment</li>
<li>Neutralization Systems</li>
<li>Scrubber Control</li>
<li>Effluent Monitoring</li>
<li>Sanitization Systems</li>
<li>Pool and Spa Control</li>
<li>Aquatic Animal Life Support Systems</li>
<li>Process Control</li>
<li>Cooling Towers &nbsp;</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 2724-2726 pH/ORP Electrodes" href="../../../../content/pdf/signet-2724-2726-ph-and-drp-electrodes.pdf" target="_blank" rel="noopener">Signet 2724-2726 pH/ORP Electrodes Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 8150 Battery-Powered Transmitter</title>
		<link>https://aquacomponents.sa/product/signet-8150-battery-powered-transmitter/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:07 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-8150-battery-powered-transmitter/</guid>

					<description><![CDATA[Signet 8150 Battery-Powered Transmitter incorporate cutting-edge features that ensures simple operations for a long duration. The software design is built with smart technology with a four-button keypard which can be utilized for convenience through the use of screen displays and system programming processes. Models Signet 8150 Battery-Powered Transmitter Specifications: General Compatibility Signet 515 and 525 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 8150 Battery-Powered Transmitter incorporate cutting-edge features that ensures simple operations for a long duration. The software design is built with smart technology with a four-button keypard which can be utilized for convenience through the use of screen displays and system programming processes.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Signet 8150 Battery-Powered Transmitter Specifications:</strong></h5>
<table class="tableCenter" style="height: 266px; width: 1161px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 10px; width: 1157.1px;" colspan="4">General</th>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; width: 234.375px; height: 25px;">Compatibility</th>
<td style="text-align: center; width: 920.739px; height: 25px;" colspan="3">Signet 515 and 525 flow sensors</td>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 234.375px; height: 36px;">Input Freq. Range</th>
<td style="text-align: center; width: 920.739px; height: 36px;">0 to 400Hz</td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; width: 234.375px; height: 10px;">Accuracy</th>
<td style="text-align: center; width: 920.739px; height: 10px;">&plusmn;0.5% of reading</td>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; width: 234.375px; height: 44px;" rowspan="3">Display</th>
<td style="text-align: center; height: 10px; width: 920.739px;">LCD Type</td>
</tr>
<tr style="height: 19px;">
<td style="text-align: center; height: 19px; width: 920.739px;">4-digit upper line &#8211; flow rate</td>
</tr>
<tr style="height: 15px;">
<td style="text-align: center; width: 920.739px; height: 15px;">8-digit lower line &#8211; volume totalizer count, either resettable or permanent</td>
</tr>
<tr style="height: 26px;">
<th style="text-align: center; width: 234.375px; height: 26px;">Averaging</th>
<td style="text-align: center; width: 920.739px; height: 26px;">0 to 120 secs.</td>
</tr>
<tr style="height: 26px;">
<th style="text-align: center; width: 234.375px; height: 26px;">Contrast</th>
<td style="text-align: center; width: 920.739px; height: 26px;">Automatic</td>
</tr>
<tr style="height: 28px;">
<th style="text-align: center; width: 234.375px; height: 28px;">Low Battery Indication</th>
<td style="text-align: center; width: 920.739px; height: 28px;">Battery symbol appears on LCD display</td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; width: 234.375px; height: 30px;">8-digit Resettable Totalizers</th>
<td style="text-align: center; width: 920.739px; height: 30px;">Stored until user resets; continues to be stored even after batteries are removed</td>
</tr>
<tr style="height: 31px;">
<th style="text-align: center; width: 234.375px; height: 31px;">8-digit Permanent</th>
<td style="text-align: center; height: 31px; width: 920.739px;">Kept permanently, even when batteries are removed</td>
</tr>
</tbody>
</table>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Three totalizers: 2 resettable and 1 permanent, user-selectable</li>
<li>Long-lasting lithium batteries</li>
<li>Mounting versatility</li>
<li>No-flow indicator</li>
<li>Large digital display with averaging</li>
<li>Simple push-button operation</li>
<li>User-selectable access code prevents unwanted changes</li>
<li>Auto-calibration</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Wastewater Flow Accumulation</li>
<li>Water Treatment Systems</li>
<li>Remote or Mobile Treatment/Distribution Systems</li>
<li>Irrigation Systems</li>
<li>Filtration Systems</li>
<li>Commercial Pools and Spas</li>
<li>Groundwater Remediation</li>
<li>RO concentrate</li>
<li>Process flow monitoring</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 8150 Battery-Powered Transmitter" href="../../../../content/pdf/signet-8150-flow-totalizer.pdf" target=" _blank">Signet 8150 Battery-Powered Transmitter Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 9900 Transmitter</title>
		<link>https://aquacomponents.sa/product/signet-9900-transmitter/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:03 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-9900-transmitter/</guid>

					<description><![CDATA[The Signet 9900 Transmitter offers advanced features for many different criterias that include temperature, salinity, pressure, flow, pH, level and other types of sensors. Transparency is improved as a result of a terrificly illuminated display that highlights the large characters and their values. Models Signet 9900 Transmitter Specifications: General Input Channels One Input Types Digital [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The Signet 9900 Transmitter offers advanced features for many different criterias that include temperature, salinity, pressure, flow, pH, level and other types of sensors. Transparency is improved as a result of a terrificly illuminated display that highlights the large characters and their values.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>Signet 9900 Transmitter Specifications:</strong></h5>
<table class="tableCenter" style="height: 228px; width: 1175px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 14px; width: 1170.74px;" colspan="5">General</th>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; height: 25px; width: 230.739px;">Input Channels</th>
<td style="text-align: center; height: 25px; width: 938.011px;" colspan="4">One</td>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; height: 36px; width: 230.739px;">Input Types</th>
<th style="text-align: center; height: 36px; width: 184.375px;">Digital (S3 L)</th>
<td style="text-align: center; width: 751.648px; height: 36px;" colspan="2">Serial ASCII, TTL level, 9600 bps</td>
</tr>
<tr style="height: 32px;">
<th style="text-align: center; width: 230.739px; height: 42px;" rowspan="2">
<p>&nbsp;</p>
</th>
<th style="text-align: center; height: 32px; width: 184.375px;">Frequency</th>
<td style="text-align: center; width: 346.193px; height: 32px;">Range</td>
<td style="text-align: center; width: 403.466px; height: 32px;">0.5 to 1500 Hz</td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; height: 10px; width: 184.375px;">
<p>&nbsp;</p>
</th>
<td style="text-align: center; width: 346.193px; height: 10px;">Accuracy</td>
<td style="text-align: center; width: 403.466px; height: 10px;">0.5% of reading</td>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; height: 12px; width: 417.102px;" colspan="2">Measurement Types</th>
<td style="text-align: center; height: 12px; width: 751.648px;" colspan="3">Flow, pH/ORP, Conductivity/Resis tivity, Salinity, Pressure, Temperature, Level, Dissolved Oxygen, Batch or user-defi ned (via 8058)</td>
</tr>
</tbody>
</table>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Large auto-sensing backlit display with &#8220;at-a-glance&#8221; visibility</li>
<li>&#8220;Dial-type&#8221; digital bar graph</li>
<li>Intuitive and &#8220;user-friendly&#8221; interface consistent with legacy Signet ProPoint&reg; and ProcessPro&reg; devices</li>
<li>Optional Field upgradable relays</li>
<li>Selectable error mode for current outputs, 3.6mA or 22mA</li>
<li>4 to 20 mA input (with optional 8058 Signal Converter)</li>
<li>Warning LED indicator</li>
<li>Custom 13-character label capabilities for the channel type</li>
<li>Factory reset capability</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Wastewater Treatment</li>
<li>Reverse Osmosis</li>
<li>Deionization</li>
<li>Chemical Manufacturing/Addition</li>
<li>Metal and Plastic Finishing</li>
<li>Fume Scrubbers</li>
<li>Cooling Towers</li>
<li>Media Filtration</li>
<li>Chemical Dosing/Injection</li>
<li>Aquatic Life Support</li>
<li>Pools &amp; Fountains</li>
<li>Rinse Tanks</li>
<li>Chemical Neutralization</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 9900 Transmitter " href="../../../../content/pdf/signet-9900-transmitter.pdf" target=" _blank">Signet 9900 Transmitter Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 8900 Multi-Parameter  Transmitter</title>
		<link>https://aquacomponents.sa/product/signet-8900-multi-parameter-transmitter/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:50:01 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-8900-multi-parameter-transmitter/</guid>

					<description><![CDATA[Signet 8900 Multi-Parameter Transmitter provides advanced designing that improves modularity to the fullest and utilizes field-commissioned integrations for users such as relays with easy to install modular screens, inputs and outputs. The instrument&#8217;s monitoring capabilities are simplified through a wide range of sensor options which include signet flow, temperature, pressure, conductivity, salinity, and dissovled oxygen. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 8900 Multi-Parameter Transmitter provides advanced designing that improves modularity to the fullest and utilizes field-commissioned integrations for users such as relays with easy to install modular screens, inputs and outputs. The instrument&#8217;s monitoring capabilities are simplified through a wide range of sensor options which include signet flow, temperature, pressure, conductivity, salinity, and dissovled oxygen.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>The Signet 8900 takes the concept of modularity to the extreme.</strong></p>
<ul>
<li>Two base-units, one with back-lit LCD and the other with Vacuum Fluorescent display can be configured in the field.</li>
<li>Ultimate flexibility is achieved via plug-in modules:<br />&mdash; Two, four or six input channels<br />&mdash; Universal AC line voltage or 12 to 24 VDC power<br />&mdash; Up to four analog outputs<br />&mdash; Up to four relays</li>
<li>The 8900 will support up to four additional relays, for a total of eight, by way of external relay modules.</li>
<li>Controller capabilities include Advanced Relay Logic, Derived Measurements, and much more!</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Measures Flow, pH, ORP, Conductivity, Pressure, Level, Temperature and Dissolved Oxygen</li>
<li>Multi-language display</li>
<li>1/4 DIN enclosure</li>
<li>Up to 4 analog outputs</li>
<li>Up to 8 relays</li>
<li>12 to 24 VDC or 100 to 240 VAC &plusmn;10%, regulated power</li>
<li>Digital communication allows for extended cable lengths and easy wiring</li>
<li>Accepts 3rd party 4 to 20 mA output devices when used with 8058 signal converter</li>
<li>Available with 2 to 6 channels</li>
<li>Simultaneous BTU Calculations with Heating &amp; Cooling Totalizers per calculation</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>RO/DI System Control</li>
<li>Media Filtration</li>
<li>Pure Water Production</li>
<li>Demineralizers</li>
<li>Chemical Processing</li>
<li>Metal &amp; Plastics Finishing</li>
<li>Fume scrubbers</li>
<li>Proportional Chemical Addition</li>
<li>Cooling Tower and Boiler Protection</li>
<li>Wastewater Treatment</li>
<li>Aquatic Animal Life Support Systems</li>
<li>Rinse Tank&nbsp;</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document"><a title="Signet 8900 Multi-Parameter Transmitter" href="../../../../content/pdf/signet-8900-multi-parameter-controller.pdf" target=" _blank">Signet 8900 Multi-Parameter Transmitter Data Sheet</a></p></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Signet 9950 Dual Channel Transmitter</title>
		<link>https://aquacomponents.sa/product/signet-9950-dual-channel-transmitter/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:49:58 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/signet-9950-dual-channel-transmitter/</guid>

					<description><![CDATA[Signet 9950 Dual Channel Transmitter is a highly simplified monitoring instrument that incorporates a variety of sensor options such as signet flow, pressure, salinity, level, temperature, conductivity, and dissolved oxygen. There are two separate readings which can be monitored by a conductivity module. Models Signet 9950 Dual Channel Transmitter Specifications: Genera Input Channels Two frequency [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Signet 9950 Dual Channel Transmitter is a highly simplified monitoring instrument that incorporates a variety of sensor options such as signet flow, pressure, salinity, level, temperature, conductivity, and dissolved oxygen. There are two separate readings which can be monitored by a conductivity module.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Signet 9950 Dual Channel Transmitter Specifications:</strong></h5>
<table class="tableCenter" style="height: 429px; width: 1160px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; height: 10px; width: 1156.19px;" colspan="4">Genera</th>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; width: 233.466px; height: 25px;">Input Channels</th>
<td style="text-align: center; width: 920.739px; height: 25px;" colspan="3">Two frequency or S3 L inputs, or optional direct conductivity modules, maximum of 2 channels</td>
</tr>
<tr style="height: 36px;">
<th colspan="4" align="left">Enclosure and Display 0 to 400Hz</th>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; width: 233.466px; height: 30px;">Case Material</th>
<td style="text-align: center; width: 920.739px; height: 30px;" colspan="3">PBT</td>
</tr>
<tr style="height: 25px;">
<th style="text-align: center; width: 233.466px; height: 10px;">Window</th>
<td style="text-align: center; width: 920.739px; height: 10px;" colspan="3">Shatter-resistant glass</td>
</tr>
<tr style="height: 26px;">
<th style="text-align: center; width: 233.466px; height: 26px;">Keypad</th>
<td style="text-align: center; width: 920.739px; height: 26px;" colspan="3">4 buttons, injection-molded silicone rubber seal</td>
</tr>
<tr style="height: 26px;">
<th style="text-align: center; width: 233.466px; height: 26px;">Display</th>
<td style="text-align: center; width: 920.739px; height: 26px;" colspan="3">Dot matrix, LCD</td>
</tr>
<tr style="height: 28px;">
<th style="text-align: center; width: 233.466px; height: 28px;">Indicators</th>
<td style="text-align: center; width: 920.739px; height: 28px;" colspan="3">Two horizontal digital bar graphs, four LED relay status indicators</td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; width: 233.466px; height: 30px;">Update Rate</th>
<td style="text-align: center; width: 920.739px; height: 30px;" colspan="3">1 s</td>
</tr>
<tr style="height: 31px;">
<th style="text-align: center; width: 233.466px; height: 31px;">LCD Contrast</th>
<td style="text-align: center; height: 31px; width: 920.739px;" colspan="3">5 settings</td>
</tr>
<tr>
<th style="text-align: center; width: 233.466px;">Size&nbsp;</th>
<td style="text-align: center; width: 920.739px;" colspan="3">&frac14; DIN</td>
</tr>
<tr>
<th colspan="4" align="justify">Mounting</th>
</tr>
<tr>
<th style="text-align: center; width: 233.466px;">Panel&nbsp;</th>
<td style="text-align: center; width: 920.739px;" colspan="3">&frac14; DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included</td>
</tr>
<tr>
<th style="text-align: center; width: 233.466px;">Wall</th>
<td style="text-align: center; width: 920.739px;" colspan="3">Wall Mount enclosure (sold as an accessory)</td>
</tr>
</tbody>
</table>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Automatic pH glass impedance measurment</li>
<li>Selectable parameters for broken glass detection</li>
<li>Reads stored data in all Signt DryLoc&reg; pH/ORP electrodes</li>
<li>One instrument for multiple sensor types</li>
<li>Two different sensor types can be combined in one instrument</li>
<li>Configurable display</li>
<li>Derived measurements</li>
<li>Advanced boolean logic</li>
<li>Optional modules can be added for additional capabilities</li>
<li>USB port for field upgrades using standard USB flash drives</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Wastewater Treatment</li>
<li>Reverse Osmosis</li>
<li>Deionization</li>
<li>Chemical Manufacturing/Addition</li>
<li>Metal and Plastic Finishing</li>
<li>Fume Scrubbers</li>
<li>Cooling Towers</li>
<li>Media Filtration</li>
<li>Chemical Dosing/Injection</li>
<li>Aquatic Life Support</li>
<li>Pools &amp; Fountains</li>
<li>Rinse Tanks</li>
<li>Chemical Neutralization&nbsp; &nbsp;</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Signet 9950 Dual Channel Transmitter" href="../../../../content/pdf/signet-9950-transmitter.pdf" target=" _blank">Signet 9950 Dual Channel Transmitter Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
