<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industrial Fleck Valves &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/industrial-fleck-valves/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:46:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Fleck 2815 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-2815-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:28 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-2815-control-valve/</guid>

					<description><![CDATA[The new Fleck 2815 control valve features a 316 grade stainless steel valve body for superior strength and durability.&#160;Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system operation Models Features and Benefits 316 grade stainless steel valve body for superior strength and durability Continuous service flow rate of 70 GPM with [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify"><span>The new Fleck 2815 control valve features a 316 grade stainless steel valve body for superior strength and durability.&nbsp;</span>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system operation</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>Features and Benefits</strong></h5>
<ul>
<li>316 grade stainless steel valve body for superior strength and durability</li>
<li>Continuous service flow rate of 70 GPM with a backwash of 70 GPM</li>
<li>Backwash capability accommodates softener tanks up to 36&#8243; in diameter and filter tanks up to 30&#8243; in diameter</li>
<li>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system operation</li>
<li>Designed for single or multiple tank systems</li>
<li>Corrosion resistant, UV stabilized NEMA 3R rated cover provides protection against water intrusion</li>
<li>Time-tested, hydraulically-balanced piston for service and regeneration</li>
<li>Seal and spacer cartridge simplifies service</li>
</ul>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Accessories and Options</strong></h5>
<ul>
<li>NPT Stainless Steel</li>
<li>100-240 VAC operating range with multiple power plug choices (some models)</li>
<li>No hard water bypass piston</li>
<li>Brine cam auxiliary switch</li>
<li>Electromechanical timer auxiliary switch</li>
<li>Black cover with black bezel. Optional blue or silver bezels only sold separately</li>
<li><span>XTR2</span>&#8211; Premium controller with large color LCD touch screen display offers intuitive navigation and a full complement of advanced features for system type 4 softeners and filters</li>
<li><span>SXT</span>&#8211; Large LCD display and user selectable time clock or metered functionality for softener and filter systems</li>
<li><span>Electromechanical Timer</span>&#8211; Simple to adjust and easy to service with quick access to all internal components</li>
<li><span>3200 Electromechanical Timer</span>&#8211; 7-day or 12-day time clock operation</li>
<li><span>3210 Electromechanical Timer</span>&#8211; Meter delayed operation</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<h5><strong>Certifications</strong></h5>
<ul>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 61 Section 8 Material Safety Only.</li>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 372 for Lead Free Compliance.</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<div>
<div class="hl-custom-tab-content document"><a title="Fleck 2815 Control Valve Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-2815-control-valve.pdf" target="_blank" rel="noopener">Fleck 2815 Control Valve Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 2815 XTR2 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-2815-xtr2-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:43:40 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-2815-xtr2-control-valve/</guid>

					<description><![CDATA[The new Fleck 2815 control valve features a 316 grade stainless steel valve body for superior strength and durability. DURABLE CONSTRUCTION Corrosion resistant stainless steel&#160;valve body means the Fleck 2815&#160;can be used in extreme conditions and&#160;environments NSF/ANSI Standard 372 certified to&#160;meet lead-free regulatory compliance Seals and components are hot water rated up to 150&#176;F, meaning [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The new Fleck 2815 control valve features a 316 grade stainless steel valve body for superior strength and durability.</p>
<h5><strong>DURABLE CONSTRUCTION</strong></h5>
<ul>
<li>Corrosion resistant stainless steel&nbsp;valve body means the Fleck 2815&nbsp;can be used in extreme conditions and&nbsp;environments</li>
<li>NSF/ANSI Standard 372 certified to&nbsp;meet lead-free regulatory compliance</li>
<li>Seals and components are hot water rated up to 150&deg;F, meaning no additional components needed</li>
</ul>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;" colspan="3">Configurations &#8211; Options</th>
</tr>
<tr>
<th style="text-align: center;">&reg; NPT Stainless Steel</th>
<th style="text-align: center;">&reg; Optional blue or silver bezels sold<br />separately</th>
<th style="text-align: center;" rowspan="2">
<p>&nbsp;</p>
<p>&reg; NXT2 &#8211; Network up to 8 valves for multisystem control. Improved display (OLED)<br />allows for easy viewing. Multivalve system<br />settings can be pushed from one controller<br />to expedite setup.<br />PVC</p>
</th>
</tr>
<tr>
<td style="text-align: center;"><strong>&reg; 100-240 VAC operating range with</strong><br /><strong>multiple power plug choices (some</strong><br /><strong>models)</strong></td>
<td style="text-align: center;"><strong>&reg; XTR2 &#8211; Premium controller with large</strong><br /><strong>color LCD touch screen display offers</strong><br /><strong>intuitive navigation and a full complement</strong><br /><strong>of advanced features for system type 4</strong><br /><strong>softeners and filters</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>&reg; No hard water bypass piston </strong></td>
<td style="text-align: center;" rowspan="4"><strong>&reg; SXT &#8211; Large LCD display and userselectable time clock or metered</strong><br /><strong>functionality for softener and filter</strong><br /><strong>systems</strong></td>
<td style="text-align: center;" rowspan="4"><strong>&reg; Electromechanical Timer- Simple to</strong><br /><strong>adjust and easy to service with quick</strong><br /><strong>access to all internal components</strong><br /><strong>3200 Electromechanical Timer7-day or 12-day time clock</strong><br /><strong>operation</strong><br /><strong>3210 Electromechanical TimerMeter delayed operation</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>&reg; Brine cam auxiliary switch </strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>&reg; Electromechanical timer auxiliary switch </strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>&reg; Black cover with black bezel </strong></td>
</tr>
</tbody>
</table>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system operation</li>
<li>Corrosion resistant, UV stabilized NEMA 3R rated cover provides protection against water intrusion</li>
<li>Time-tested, hydraulically-balanced piston for service and regeneration</li>
<li>Seal and spacer cartridge simplifies service</li>
</ul>
<h5><strong>PEAK PERFORMANCE</strong></h5>
<ul>
<li>Continuous service flow and backwash&nbsp;rates of 70 GPM</li>
<li>High backwash capability&nbsp;accommodates tanks up to 36&rdquo; in&nbsp;diameter and filters up to 30&rdquo; in&nbsp;diameter (based on 10 GPM/ft2)</li>
<li>Hydraulically-balanced composite piston&nbsp;for durable sealing and performance</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<p><span>Ideal for smaller size commercial/industrial&nbsp;</span><em>applications</em></p>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 2815 XTR2 control valve brochure" href="https://www.pureaqua.com/content/pdf/fleck-2815-xtr2-control-valve-brochure.pdf" target="_blank" rel="noopener">Fleck 2815 XTR2 Control Valve Brochure</a><br /><a title="Fleck 2815 XTR2 control valve manual" href="https://www.pureaqua.com/content/pdf/fleck-2815-xtr2-control-valve-manual.pdf" target="_blank" rel="noopener">Fleck 2815 XTR2 Control Valve Manual</a><br /><a title="Fleck 2815 XTR2 control valve specifications" href="https://www.pureaqua.com/content/pdf/fleck-2815-xtr2-control-valve-specifications.pdf" target="_blank" rel="noopener">Fleck 2815 XTR2 Control Valve Specifications</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 3150 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-3150-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:55 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-3150-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<h4><strong>Uses for Fleck 3150</strong></h4>
<p align="justify">The Fleck 3150 is the a great backwash valve, designed and manufactured to work on heavy duty applications. Five-cycle control delivers controlled upflow backwash, downflow brining, slow rinse, rapid rinse and timed brine refill, are all performed with conditioned water. Continuous flow rates up to 100gpm, 129 gpm peak. Handles tanks up to 63&#8243; in diameter.&nbsp;</p>
<h5><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li align="justify">Specify the valve needed is for back wash filter or water softener.</li>
<li align="justify">Specify the flow rate needed for your application</li>
<li align="justify">Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li align="justify">Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<div>
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Lead-free brass</td>
<td style="text-align: center; height: 18px; width: 170px;">1&#8243; NPTM</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="3"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Flow rate (50 psi Inlet)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Top mount</strong></th>
<th style="text-align: center; width: 170px;"><strong>Side mount</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Continuous (15 psi drop)</td>
<td style="text-align: center; width: 170px;">95 GPM</td>
<td style="text-align: center; width: 170px;">100 GPM</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Peak (25 psi drop)</td>
<td style="text-align: center; width: 170px;">124 GPM</td>
<td style="text-align: center; width: 170px;">129 GPM</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Cv (flow at 1 psi drop)</td>
<td style="text-align: center; width: 170px;">24.8</td>
<td style="text-align: center; width: 170px;">25.9</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Max. backwash (25 psi drop)</td>
<td style="text-align: center; width: 170px;">105 GPM</td>
<td style="text-align: center; width: 170px;">109 GPM</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Both</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">Electromechanical: 164 minutes<br />3200NXT: 240 minutes per cycle<br />3214NXT: 240 minutes per cycle<br />XT: Up to 240 minutes per cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 157px; width: 1169px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1164.38px;" colspan="2">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 577.102px; height: 36px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 36px; width: 585.284px;" colspan="1"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; width: 577.102px; height: 16px;">3 &#8211; 150 GPM +/- 5%</td>
<td style="text-align: center; width: 585.284px; height: 16px;">Standard: 1,250 &#8211; 21,250<br />Extended: 6,250 &#8211; 106,250<br />3200NXT: 2,900,000<br />3214NXT: 9,900,000<br />XT: 1,000 &#8211; 9,900,000</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 138.92px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 203.466px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Brine line</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Injector System</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 138.92px; height: 10px;">2&#8243; pipe I.D.</td>
<td style="text-align: center; width: 203.466px; height: 10px;">2&#8243; NPTF</td>
<td style="text-align: center; width: 200.739px; height: 10px;">1&#8243; NPTM</td>
<td style="text-align: center; width: 161.648px; height: 10px;">1&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">Top mount: 4&#8243; &#8211; 8 UN</td>
<td style="text-align: center; width: 200.739px; height: 10px;">10&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="5"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Max. VA</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">24 v, 110 v, 220 v &#8211; 50 Hz, 60 Hz</td>
<td style="text-align: center; width: 254.375px; height: 10px;">72</td>
<td style="text-align: center; width: 319.83px; height: 10px;">Time clock: 39 lbs.<br />Metered value: 46 lbs.</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">34&deg; &#8211; 110&deg;F</td>
</tr>
</tbody>
</table>
<p> </p>
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product&nbsp;</p>
<p>also meets California Proposition 65 Standards</p>
</p>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>F</strong><strong>leck 3900 &#8211;&nbsp;3&#8243; Commercial Control Valve&nbsp;</strong><strong>Features:</strong></h5>
<ul>
<li>Fully adjustable, 5-cycle control delivers upflow back wash, downflow brining, slow rinse, rapid rinse and down flow service</li>
<li>Designed for single tank or multi-tank systems, alternating or interlocking</li>
<li>Continuous flow rate of 250 GPM</li>
<li>Protective NEMA 3R enclosure is water-resistant, corrosion-resistant, and UV stable</li>
<li>Choice of 7 or 12 day clock or meter initiated regeneration</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<div>
<h5><strong>Options:</strong></h5>
<ul>
<li>Meter-initiated regeneration</li>
<li>Upflow regeneration</li>
<li>Service valve operator</li>
<li>No hard water bypass</li>
<li>Auxiliary switches</li>
<li>Side mount</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial or Industrial Softeners</li>
<li>Commercial or Industrial Media Filters</li>
<li>Commercial or Industrial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul></div>
</p>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 3150 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-3150-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 3150 Spec Sheet</a> <br /><a title="Fleck 3150 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-3150-service-manual.pdf" target="_blank" rel="noopener">Fleck 3150 Service Manual</a></div>
</p></div>
</p></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 9500 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-9500-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:55 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-9500-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<h4 align="justify"><strong>Uses for Fleck 9500</strong></h4>
<p align="justify">The Fleck 9500 is the commercial version of the 9000 valve. Twin-tank design means that soft water is available at all times. Five-cycle control delivers controlled upflow backwash, downflow brining, slow rinse, rapid rinse and timed brine refill, are all performed with conditioned water. The most salt-efficient valve available because you don&#8217;t need to program in a reserve. Regenerates immediately when needed, as often as every 90 minutes if required. Continuous flow rates up to 41 gpm, 49 gpm peak. Handles softeners up to 24&#8243; in diameter. Order cover separately. <a href="../../../../twin-tank-water-softener/" target="_blank" rel="noopener">Please visit our SF-900F to learn more about our fully integrated twin water softeners.</a></p>
<h5 align="justify"><strong>Want to order Fleck Valves?</strong></h5>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<div style="overflow-x: auto;">
<table class="tableCenter tableLeft" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Valve Specifications:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Valve material</td>
<td style="width: 151px; text-align: left;">Lead-free brass*</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Inlet/Outlet</td>
<td style="width: 151px; text-align: left;">1-1/2&#8243; NPTF</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Cycles</td>
<td style="width: 151px; text-align: left;">5</td>
</tr>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Continuous (15 psi drop)</td>
<td style="width: 151px; text-align: left;">38 GPM</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Peak (25 psi drop)</td>
<td style="width: 151px; text-align: left;">49 GPM</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Cv (flow at 1 psi drop)</td>
<td style="width: 151px; text-align: left;">9.8</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Max. backwash (25 psi drop)</td>
<td style="width: 151px; text-align: left;">16 GPM</td>
</tr>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Regeneration:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Downflow/Upflow</td>
<td style="width: 151px; text-align: left;">Downflow only</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Adjustable cycles</td>
<td style="width: 151px; text-align: left;">Yes</td>
</tr>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Electromechanical:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Time available</td>
<td style="width: 151px; text-align: left;">82 or 164 minutes</td>
</tr>
<tr>
<td style="height: 40px; width: 151px; text-align: left;" rowspan="2">Meter Information</td>
<td style="width: 151px; text-align: left;">SXT: 0 &#8211; 199 minutes per cycle</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">XT: 240 minutes per cycle</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Meter accuracy</td>
<td style="width: 151px; text-align: left;">1-1/2 &#8211; 75 GPM</td>
</tr>
<tr>
<td style="height: 80px; width: 151px; text-align: left;" rowspan="4">Meter capacity range (gal.)</td>
<td style="width: 151px; text-align: left;">Standard: 625 &#8211; 10,625</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Extended: 3,125 &#8211; 53,125</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">SXT: 1 &#8211; 999 900</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">XT: 1,000 &#8211; 9,900,000</td>
</tr>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Dimensions:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Distributor pilot</td>
<td style="width: 151px; text-align: left;">1.5&#8243; pipe I.D.</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Drain line</td>
<td style="width: 151px; text-align: left;">1&#8243; NPTM</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Injector brine system</td>
<td style="width: 151px; text-align: left;">1/2&#8243; &amp; 3/8&#8243;</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Mounting base</td>
<td style="width: 151px; text-align: left;">4&#8243; &#8211; 8 UN</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Height from top of tank</td>
<td style="width: 151px; text-align: left;">7-1/4&#8243;</td>
</tr>
<tr>
<td style="height: 20px; width: 301px; text-align: left;" colspan="2"><strong>Additional Information:</strong></td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Electrical rating</td>
<td style="width: 151px; text-align: left;">24 v, 110 v, 200 v &#8211; 50 Hz, 60 Hz</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Max. VA</td>
<td style="width: 151px; text-align: left;">8.9</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Estimated shipping weight</td>
<td style="width: 151px; text-align: left;">Metered value: 48 lbs.</td>
</tr>
<tr>
<td style="height: 40px; width: 151px; text-align: left;" rowspan="2">Pressure</td>
<td style="width: 151px; text-align: left;">Hydrostatic: 300 psi</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Working: 25 &#8211; 125 psi</td>
</tr>
<tr>
<td style="height: 20px; width: 151px; text-align: left;">Temperature</td>
<td style="width: 151px; text-align: left;">34o&nbsp;&#8211; 110o&nbsp;F</td>
</tr>
<tr>
<td style="height: 40px; width: 301px; text-align: left;" colspan="2" rowspan="2">* As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards</td>
</tr>
</tbody>
</table></div>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Fleck 9500 &#8211;&nbsp;</strong><strong>1.5&#8243; Twin Tank Commercial Control Valve</strong></h5>
<div>
<ul>
<li>Easily-adjustable, 5-cycle, downflow-brining control</li>
<li>Rugged, long-life construction features a lead-free brass valve body</li>
<li>Uses conditioned water for regeneration</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<h5><strong>Options:</strong></h5>
<div>
<ul>
<li>Hot water (150&deg;F)</li>
<li>Electronic timer, SE or XT</li>
</ul></div>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial Twin Water Softener</li>
<li>Industrial Twin Water Softener</li>
<li>Nitrate Removal System</li>
<li>Iron Removal System</li>
</ul></div>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 9500 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-9500-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 9500 Spec Sheet</a> <br /><a title="Fleck 9500 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-9500-service-manual.pdf" target="_blank" rel="noopener">Fleck 9500 Service Manual</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 2750 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-2750-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:54 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-2750-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<p>The Fleck 2750 commercial valve is a 1 inch valve, with a 1 inch inlet and outlet as well as a 1 inch distributor pilot. Typically, the 2750 valve is used on 10 inch diameter to 24 inch diameter pressure vessels. The 2750 commercial valve is top mounted or side mounted depending on the requirements of the application. The valve has a Cv of 6.8 GPM and can backwash up to 25 GPM. The weight of just the valve is approximately 13 pounds with a working pressure range of 20 to 125 psi. Operating temperatures range from 34 degrees to 110 degrees Fahrenheit. When the 2750 valve is used for a water softener application a 1600, 1650, or 1700 brine valve is used.</p>
<p><strong>How to Order Fleck Valve?</strong></p>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<div>
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Lead-free brass</td>
<td style="text-align: center; height: 18px; width: 170px;">1&#8243; NPTM</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</p></div>
<div>
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone:</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Continuous (15 psi drop)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Peak (25 psi drop)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Cv flow at 1 psi drop</strong></th>
<th style="text-align: center; width: 170px;"><strong>Max. Backwash 25 psi drop</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">26 GPM</td>
<td style="text-align: center; width: 170px;">33 GPM</td>
<td style="text-align: center; width: 170px;">6.8</td>
<td style="text-align: center; width: 170px;">25 GPM</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Downflow only</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">Electromechanical: 164 minutes<br />SXT: 199 minutes per cycle<br />NXT: 240 minutes per cycle<br />XT: 240 minutes per cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 100px; width: 1167px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1162.56px;" colspan="3">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 588.011px; height: 36px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 36px; width: 572.557px;" colspan="1"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; height: 46px; width: 588.011px;">.75&#8243; &#8211; .25 &#8211; 15 GPM +/- 5%</td>
<td style="text-align: center; width: 572.557px; height: 46px;">Standard: 310 &#8211; 5,270<br />Extended: 1,550 &#8211; 26,350<br />SXT: 1 &#8211; 999,900<br />NXT: 9,900,000<br />XT: 1,000 &#8211; 9,900,000</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 138.92px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 203.466px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Brine line</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Injector System</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 138.92px; height: 10px;">1.05&#8243; O.D.</td>
<td style="text-align: center; width: 203.466px; height: 10px;">3/4&#8243; NPTM</td>
<td style="text-align: center; width: 200.739px; height: 10px;">3/8&#8243; &amp; 1/2&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">1600 &amp; 1050 &#8211; 3/8&#8243;<br />1700 &amp; 1710 &#8211; 1/2&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">2-1/2&#8243; &#8211; 8 NPSM</td>
<td style="text-align: center; width: 200.739px; height: 10px;">6 &#8211; 1/2&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="5"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">24 v, 110 v, 220 v &#8211; 50 Hz, 60 Hz</td>
<td style="text-align: center; width: 319.83px; height: 10px;">Time clock: 13 lbs.<br />Metered valve: 26 lbs.</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">34&deg; &#8211; 110&deg;F</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 5px;" width="1103" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1098.92px;" colspan="5"><strong>Typical Applications</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 544px;"><strong>Water softener</strong></th>
<th style="text-align: center; width: 544px;"><strong>Filters</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 544px;">10&#8243; &#8211; 24&#8243; diameter</td>
<td style="text-align: center; width: 544px;">10&#8243; &#8211; 21&#8243; diameter</td>
</tr>
</tbody>
</table></div>
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product</p>
<p>also meets California Proposition 65 Standards</p>
<p>** 24 VAC Pentair Transformers:</p>
<p>{C}{C}115 VAC +/- 20% Input, 24 VAC Output</p>
<p>{C}{C}230 VAC +/- 20% Input, 24 VAC Output</p>
<p>{C}{C} </p>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>1&#8243; Commercial Control Valve</strong></h5>
<div>
<ul>
<li>Suitable for large residential/light commercial applications</li>
<li>Fully adjustable, 5-cycle control delivers controlled upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill and downflow service</li>
<li>Backwash capacity handles tanks up to 24&#8243; diameter</li>
<li>Mechanical control (7- or 12-day clock or metered initiated regeneration)</li>
<li>Valve body is solid, lead-free brass</li>
<li>Time tested, hydraulically-balanced piston, seal, and spacer concept to pilot service flow and regeneration</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<h5><strong>Options:</strong></h5>
<div>
<ul>
<li>Backwash filter</li>
<li>Hot water (time clock 180&deg;F, meter 150&deg;F)</li>
<li>Meter-initiated regeneration</li>
<li>Manual operation</li>
<li>Service valve operator</li>
<li>No hard water bypass</li>
<li>Electronic timer, SE, XT, 3214NXT, or 3200NT</li>
<li>Environmental cover</li>
<li>Auxiliary switches</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial softeners</li>
<li>Commercial Media Filters</li>
<li>Commercial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 2750 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-2750-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 2750 Spec Sheet</a> <br /><a title="Fleck 2750 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-2750-service-manual.pdf" target="_blank" rel="noopener">Fleck 2750 Service Manual</a><br /><a title="Fleck 2750 Service Manual Upflow" href="https://www.pureaqua.com/content/pdf/fleck-2750-service-manual-upflow.pdf" target="_blank" rel="noopener">Fleck 2750 Service Manual Upflow</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 2850 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-2850-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:54 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-2850-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<h4 align="justify"><strong>Fleck 2850</strong></h4>
<p align="justify">The Fleck 2850 commercial valve is a 1.5 inch valve, with a 1.5 inch inlet and outlet as well as a 1.5 inch distributor pilot. Typically, the 2850 valve is used on 10 inch diameter to 36 inch diameter pressure vessels. The 2850 commercial valve has the ability to be top mounted or side mounted depending on the requirements of the application. The valve has a Cv of 13.2 GPM and can backwash up to 49 GPM. The weight of just the valve is approximately 19 pounds with a working pressure range of 20 to 125 psi. Operating temperatures range from 34 degrees to 110 degrees Fahrenheit. When the 2850 valve is used for a water softener application a 1600, 1650, or 1700 brine valve is used.<strong>&nbsp;</strong></p>
<h5 align="justify"><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<div>
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Lead-free brass</td>
<td style="text-align: center; height: 18px; width: 170px;">1&#8243; NPTM</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone:</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Continuous (15 psi drop)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Peak (25 psi drop)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Cv (flow at 1 psi drop)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Max. backwash (25 psi drop)</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">70 GPM side mount/top mount</td>
<td style="text-align: center; width: 170px;">90 GPM side mount/top mount</td>
<td style="text-align: center; width: 170px;">18</td>
<td style="text-align: center; width: 170px;">70 GPM</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Downflow only</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">Electromechanical: 164 minutes<br />SXT: 199 minutes per cycle<br />NXT: 0-12 hours per cycle<br />XT: 0-12 hours per cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 197px; width: 1175px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1170.74px;" colspan="10">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 380.739px; height: 36px;" colspan="3"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 36px; width: 788.011px;" colspan="7"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<th style="text-align: center; width: 118.92px; height: 16px;">1&#8243; Paddle:</th>
<th style="text-align: center; width: 125.284px; height: 16px;">1-1/2&#8243; Paddle:</th>
<th style="text-align: center; width: 132.557px; height: 16px;">1-1/2&#8243; Turbine:</th>
<th style="text-align: center; width: 95.2841px; height: 16px;">1&#8243; Standard:</th>
<th style="text-align: center; width: 118.011px; height: 16px;">1&#8243; Extended:</th>
<th style="text-align: center; width: 103.466px; height: 16px;">1-1/2&#8243; Standard:</th>
<th style="text-align: center; width: 115.284px; height: 16px;">1-1/2&#8243; Extended:</th>
<th style="text-align: center; width: 93.4659px; height: 16px;">SXT:</th>
<th style="text-align: center; width: 97.1023px; height: 16px;">NXT:</th>
<th style="text-align: center; width: 153.466px; height: 16px;">XT:</th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; height: 46px; width: 118.92px;">0.7 &#8211; 40 GPM &plusmn; 5%<br />(0.16 &#8211; 9 m&sup3;/h)</td>
<td style="text-align: center; width: 125.284px; height: 46px;">1.5 &#8211; 75 GPM &plusmn; 5%<br />(0.34 &#8211; 17 m&sup3;/h)</td>
<td style="text-align: center; width: 132.557px; height: 46px;">2 &#8211; 40 GPM +5/-8%<br />(0.45 &#8211; 9 m&sup3;/h)</td>
<td style="text-align: center; width: 95.2841px; height: 46px;">310 &#8211; 5,270 gal<br />(1.2 &#8211; 20 m&sup3;)</td>
<td style="text-align: center; width: 118.011px; height: 46px;">1,550 &#8211; 26,350 gal<br />(1.2 &#8211; 20 m&sup3;)</td>
<td style="text-align: center; width: 103.466px; height: 46px;">625 &#8211; 10,625 gal<br />(2.5 &#8211; 40 m&sup3;)</td>
<td style="text-align: center; width: 115.284px; height: 46px;">3,125 &#8211; 53,125 gal<br />(12 &#8211; 200 m&sup3;)</td>
<td style="text-align: center; width: 93.4659px; height: 46px;">1 &#8211; 999,900 gal<br />(0 &#8211; 3,785 m&sup3;)</td>
<td style="text-align: center; width: 97.1023px; height: 46px;">1 &#8211; 9,900,000 gal<br />(0 &#8211; 37,476 m&sup3;)</td>
<td style="text-align: center; width: 153.466px; height: 46px;">1,000 &#8211; 9,900,000 gal<br />(3.8 &#8211; 37,476 m&sup3;)</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 138.92px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 203.466px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Brine line</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Injector System</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 138.92px; height: 10px;">1-9/10&#8243; O.D.</td>
<td style="text-align: center; width: 203.466px; height: 10px;">1-1/4&#8243; NPTF</td>
<td style="text-align: center; width: 200.739px; height: 10px;">3/8&#8243; &amp; 1/2&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">1600 &amp; 1650 &#8211; 3/8&#8243;<br />1710 &#8211; 1/2&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">4&#8243; &#8211; 8 UN</td>
<td style="text-align: center; width: 200.739px; height: 10px;">6 &#8211; 1/2&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="5"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Max. VA</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">24 v, 110 v, 220 v &#8211; 50 Hz, 60 Hz</td>
<td style="text-align: center; width: 254.375px; height: 10px;">72</td>
<td style="text-align: center; width: 319.83px; height: 10px;">Time clock: 19 lbs.<br />Metered valve: 27 lbs.</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">Cold water: 34&deg; &#8211; 110&deg;F<br />Hot water: 180&deg;F</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 5px;" width="1103" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1098.92px;" colspan="5"><strong>Typical Applications</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 544px;"><strong>Water softener</strong></th>
<th style="text-align: center; width: 544px;"><strong>Iron Filter</strong></th>
<th style="text-align: center; width: 544px;"><strong>Sediment Filter</strong></th>
<th style="text-align: center; width: 544px;"><strong>Carbon Filter</strong></th>
<th style="text-align: center; width: 544px;"><strong>Neutralizing Filter</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 544px;">14&#8243; &#8211; 36&#8243; diameter</td>
<td style="text-align: center; width: 544px;">14&#8243; &#8211; 30&#8243; diameter</td>
<td style="text-align: center; width: 544px;">14&#8243; &#8211; 30&#8243; diameter</td>
<td style="text-align: center; width: 544px;">14&#8243; &#8211; 30&#8243; diameter</td>
<td style="text-align: center; width: 544px;">14&#8243; &#8211; 30&#8243; diameter</td>
</tr>
</tbody>
</table></div>
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product&nbsp;</p>
<p>also meets California Proposition 65 Standards</p>
<p><strong>&nbsp;</strong></p>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Model 2850s</strong>&nbsp;<strong>&#8211;&nbsp;</strong><strong>1.5&#8243; Commercial Control Valve</strong></h5>
<div>
<ul>
<li>Offers best-in-class flow rates in a 1.5&#8243; commercial valve</li>
<li>Multi-tank system capability</li>
<li>Increased service and backwash flow</li>
<li>Fully adjustable 5-cycle control delivers controlled upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill and downflow service</li>
<li>Time-tested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration</li>
<li>Solid lead-free brass valve body for superior strength and durability</li>
<li>1.5&#8243; top mount control valve ideal&nbsp; for smaller size commercial/industrial applications</li>
<li>Backwash capacity handles up to 36&#8243; diameter tanks for softeners</li>
<li>Ideal for most filter applications up to 30&#8243; diameter tanks</li>
<li>Consistent brining regardless of salt levels with timed brine refills</li>
<li>Choice of 7 or 12 day clock, manual or meter</li>
<li>Continuous service flow rate of 70 GPM with a backwash of 70 GPM</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<h5><strong>Options:</strong></h5>
<div>
<ul>
<li>Meter initiated regeneration</li>
<li>Time clock</li>
<li>No untreated water bypass piston</li>
<li>Environmental cover</li>
<li>Electromechanical, SXT, or NXT</li>
<li>Hot water (time clock 180&deg;F; metered valve 150&deg;F)</li>
<li>Manual operation</li>
<li>Service valve operator</li>
<li>Auxiliary switch</li>
<li>Side mount</li>
<li>Cold water (100&deg; F)</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial Softeners</li>
<li>Commercial Media Filters</li>
<li>Commercial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 2850 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-2850-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 2850 Spec Sheet</a> <br /><a title="Fleck 2850 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-2850-service-manual.pdf" target="_blank" rel="noopener">Fleck 2850 Service Manual</a></div>
</p></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 2900 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-2900-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:54 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-2900-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<h4><strong>2900 Fleck Control Valve for Media Filters &amp; Softeners</strong></h4>
<p align="justify">The Fleck 2900 is a 2&#8243; &nbsp;top mounted control valve ideal for &nbsp;commercial/industrial applications. Fully adjustable, 5-cycle regeneration. Solid brass valve body. Continuous flow rate of 106 gpm with up to a 140 gpm backwash rate. Up to 30&#8243; softener tanks, 36&#8243; filters. Timer- or meter-initiated regeneration. For use with single or multiple tank systems.</p>
<h5><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>NXT</strong> &#8211; Network controller uses onboard communication capabilities to link multiple valves (via off-the-shelf CAT3, CAT5, or better cables) for system types 4,5,6,7,9,and 14</p>
<p align="justify"><strong>XT</strong> &#8211; Offers a two-line, 16 character LCD backlit display for easy entering of master and user programing as well as view of diagnostics</p>
<p align="justify"><strong>Electromechanical Timer</strong> &#8211; Simple to adjust and easy to service with quick access to all internal components</p>
</p>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p> <strong>Fleck 2900s</strong> </p>
<h5><strong>Product Features and Benefits:</strong></h5>
<div>
<ul>
<li>Incorporates 2 time-tested, hydraulically-balanced pistons to independently pilot service flow and regeneration</li>
<li>For use with single or multiple tank systems</li>
<li>Backwashes softener tanks up to 36&#8243; diameter</li>
<li>Continuous flow rate of 106 GPM</li>
<li>Available with 7 or 12 day timer or meter to control regeneration</li>
<li>Lead-free brass valve body for superior strength and durability</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<h5><strong>Product Options:</strong></h5>
<div>
<ul>
<li>Meter-initiated regeneration</li>
<li>No hard water bypass</li>
<li>Electronic timer</li>
<li>Service valve operator</li>
<li>Auxiliary switches</li>
<li>Hot water (time clock downflow only &#8211;&nbsp;180&deg;F)</li>
<li>Environmental cover</li>
<li>Upflow regeneration</li>
<li>Side mount</li>
<li>Treated water regeneration</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial or Industrial Softeners</li>
<li>Commercial or Industrial Media Filters</li>
<li>Commercial or Industrial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul></div>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 2900 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-2900-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 2900 Spec Sheet</a> <br /><a title="Fleck 2900 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-2900-service-manual.pdf" target="_blank" rel="noopener">Fleck 2900 Service Manual</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 3900 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-3900-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:54 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-3900-control-valve/</guid>

					<description><![CDATA[At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">At Pure Aqua Inc., you will find a great variety of fleck valves products such as Fleck 5600, 2750, 9000, 9100, 9500, 3150, 3900, 2850. For more than 50 years, Fleck has led the way in advancing control valve technology for water treatment, softening and filtration applications. Fleck offers more than 20 models with 90 different options and over 1,000 configurations.</p>
<h4><strong>Fleck 3900 3&#8243; Commercial Control Valve&nbsp;</strong></h4>
<p align="justify">The Fleck 3900 is a great backwash and brine valve, designed and manufactured to work on heavy duty applications. Five-cycle control delivers controlled upflow backwash, downflow brining, slow rinse, rapid rinse and timed brine refill, are all performed with conditioned water. Continuous flow rates up to 250, 300 gpm peak. Handles tanks up to 63&#8243; in diameter.</p>
<h5><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<div>
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Lead-free brass</td>
<td style="text-align: center; height: 18px; width: 170px;">3&#8243; NPTM</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="2"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone:</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Flow rate (50 psi Inlet)</strong></th>
<th style="text-align: center; width: 170px;"><strong>Top mount</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Continuous (15 psi drop)</td>
<td style="text-align: center; width: 170px;">250 GPM</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Peak (25 psi drop)</td>
<td style="text-align: center; width: 170px;">325 GPM</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Cv (flow at 1 psi drop)</td>
<td style="text-align: center; width: 170px;">65</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Max. backwash (25 psi drop)</td>
<td style="text-align: center; width: 170px;">100 GPM</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Both</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">Electromechanical: 164 minutes<br />3200NXT: 240 minutes per cycle<br />3214NXT: 240 minutes per cycle<br />XT: 240 minutes per cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 116px; width: 1167px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1162.56px;" colspan="2">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 573.466px; height: 36px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 36px; width: 587.102px;" colspan="1"><strong>Meter Capacity Range(gal)</strong></th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; width: 573.466px; height: 16px;">7 &#8211; 300 GPM +/- 5%</td>
<td style="text-align: center; width: 587.102px; height: 16px;">Standard: 3,750 &#8211; 63,750<br />Extended: 18,750 &#8211; 318,750<br />3200NXT: 9,900,000<br />3214NXT: 9,900,000<br />XT: 9,900,000</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 138.92px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 203.466px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Injector System</strong></th>
<th style="text-align: center; width: 161.648px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 200.739px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 138.92px; height: 10px;">3&#8243; O.D</td>
<td style="text-align: center; width: 203.466px; height: 10px;">2&#8243; NPTF</td>
<td style="text-align: center; width: 161.648px; height: 10px;">1&#8243;</td>
<td style="text-align: center; width: 161.648px; height: 10px;">Top: 6&#8243; &#8211; 8 threaded or flanged</td>
<td style="text-align: center; width: 200.739px; height: 10px;">15&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="4"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">24 v, 110 v, 220 v &#8211; 50 Hz, 60 Hz</td>
<td style="text-align: center; width: 319.83px; height: 10px;">Time clock: 93 lbs.<br />Metered value: 115 lbs.</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">34&deg; &#8211; 110&deg;F</td>
</tr>
</tbody>
</table></div>
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product</p>
<p>also meets California Proposition 65 Standards</p>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Fleck 3150 </strong>&#8211;&nbsp;<strong>2&#8243; Commercial Control Valve</strong></h5>
<ul>
<li>Fully adjustable, 5-cycle control is efficient and reliable, delivering controlled upflow backwash, downflow brining and downflow service</li>
<li>Versatile top or side mount is&nbsp;suitable for commercial or industrial applications</li>
<li>Backwash capacity accommodates tanks up to 63&#8243; diameter</li>
<li>Solid, lead-free brass construction for superior strength and durability</li>
<li>Protective NEMA 3R equivalent enclosure is rain tight, and UV stable</li>
<li>Flexible 7 or 12 day time clock or meter initiated regeneration</li>
<li>Ideal for most filter applications up to 42&#8243;</li>
<li>TESTED AND CERTIFIED By the WQA To NSF/ANSI SDT. 61 Section 8 Material Safety Only and ANNEX &#8220;G&#8221;</li>
</ul>
<h5><strong>Options:</strong></h5>
<ul>
<li>Backwash filter</li>
<li>Meter initiated regeneration</li>
<li>Service valve operator</li>
<li>Side mount</li>
<li>Electronic timer, 3200NT, 3214NT, or XT</li>
<li>Hot water (time clock 180&deg;F; metered valve 150&deg;F)</li>
<li>No hard water bypass</li>
<li>Upflow regeneration</li>
<li>Auxiliary switch</li>
</ul></div>
</p>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial or Industrial Softeners</li>
<li>Commercial or Industrial Media Filters</li>
<li>Commercial or Industrial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul></div>
</p>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 3900 Spec Sheet" href="https://www.pureaqua.com/content/pdf/fleck-3900-spec-sheet.pdf" target="_blank" rel="noopener">Fleck 3900 Spec Sheet</a> <br /><a title="Fleck 3900 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-3900-service-manual.pdf" target="_blank" rel="noopener">Fleck 3900 Service Manual</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
