<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hydranautics HYDRAsub (MBR) Modules &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/hydranautics-hydrasub-mbr-modules/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:51:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Hydranautics HYDRAsub HSM60-ES-HSE15</title>
		<link>https://aquacomponents.sa/product/hydranautics-hydrasub-hsm60-es-hse15/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:51:31 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-hydrasub-hsm60-es-hse15/</guid>

					<description><![CDATA[Hydranautics HYDRAsub HSM60-ES-HSE15 has been developed by one of the leading membrane technology manufacturers, Hydranautics, for the purposes of enhancing biological wastewater treatment in industrial and muncipal applications. These membrane modules are incorporated with PVDF hollow fiber technology and effectively produces higher quality water for use in many water treatment processes such as RO treatment. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics HYDRAsub HSM60-ES-HSE15 has been developed by one of the leading membrane technology manufacturers, Hydranautics, for the purposes of enhancing biological wastewater treatment in industrial and muncipal applications. These membrane modules are incorporated with PVDF hollow fiber technology and effectively produces higher quality water for use in many water treatment processes such as RO treatment. MBR works in delivering a high operating flux, durable construction for long term use, and a reduced footprint that dramatically lowers energy consumption and saves cost.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div>
<table class="tableCenter" style="height: 28px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th>&nbsp;</th>
<td style="text-align: center;"><strong>HYDRAsub&reg; &#8211; MBR </strong></td>
<td style="text-align: center;"><strong><span>HSM45 w/ HSE15</span></strong></td>
</tr>
<tr style="height: 10px;">
<th style="width: 143.466px; height: 10px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 10px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:</td>
<td style="width: 258.011px; height: 10px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &micro;m<br />4 (15 m&sup2; each)<br />645 ft&sup2; (60 m&sup2;)<br />(2)- 2&rdquo; MNPT<br />(2)- 1 1/2&rdquo; MNPT<br />(2)- to fit 2.5&rdquo; pipes</td>
</tr>
</tbody>
</table></div>
<div>
<table class="tableCenter" style="height: 71px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>Typical Dry Weight</strong></td>
<td style="text-align: center;"><strong>Typical Wet Weight</strong></td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center;">HSM60-ES-HSE15</th>
<td style="text-align: center;">256 lbs (116 kg)</td>
<td style="text-align: center;">356 lbs (162 kg)</td>
</tr>
<tr style="height: 23px;">
<th style="text-align: center;">HSM60-ES15-316</th>
<td style="text-align: center;">258 lbs (117 kg)</td>
<td style="text-align: center;">358 lbs (163 kg)</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features</strong></h5>
<ul>
<li>Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)</li>
<li>Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)</li>
<li>Maximum Instantaneous Chlorine Concentration: 5,000 ppm<sup>a</sup></li>
<li>Maximum Chlorine Tolerance: 742,000 ppm-hrs<sup>b</sup></li>
<li>MLSS Range: 8,000 &#8211; 12,000 mg/L<sup>c</sup></li>
<li>Operating Temperature Range: 41 &#8211; 104&deg;F (5 &#8211; 40&deg; C)</li>
<li>Feed Water pH Range: 6.0 &#8211; 8.0</li>
<li>Cleaning pH Range: 1.0 &#8211; 11.0</li>
<li>Operating Mode:Outside to Inside</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Hydranautics HYDRAsub HSM60-ES-HSE15 utilizes a stainless steel cage for more optimized aeration and is applied in various industries from food &amp; beverages to the textile and chemical productions</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Hydranautics HYDRAsub HSM60-ES-HSE15 Data Sheet" href="../../../../content/pdf/hydranautics-hydrasub-hsm60-es-hse15.pdf" target=" _blank" rel="noopener">Hydranautics HYDRAsub HSM60-ES-HSE15 Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics HYDRAsub HSM45-ES-HSE15</title>
		<link>https://aquacomponents.sa/product/hydranautics-hydrasub-hsm45-es-hse15/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:51:28 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-hydrasub-hsm45-es-hse15/</guid>

					<description><![CDATA[Hydranautics has developed a MBR module called the HYDRAsub HSM45-ES-HSE15 that contains PVDF hollow fiber and is designed to work specifically in applications that need biological treatment. These modules necessitate standard activated sludge treatment for the purposes of producing high quality water. MBR treated water is generally safer to use in many other processes such [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics has developed a MBR module called the HYDRAsub HSM45-ES-HSE15 that contains PVDF hollow fiber and is designed to work specifically in applications that need biological treatment. These modules necessitate standard activated sludge treatment for the purposes of producing high quality water. MBR treated water is generally safer to use in many other processes such as RO treatment, and reduces the footprint by taking out the sedimentation tank. Industrial and municipal wastewater projects are the most common industries that utilize MBR modules.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div>
<table class="tableCenter" style="height: 28px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th>&nbsp;</th>
<td style="text-align: center;"><strong>HYDRAsub&reg; &#8211; MBR </strong></td>
<td style="text-align: center;"><strong><span>HSM45 w/ HSE15</span></strong></td>
</tr>
<tr style="height: 10px;">
<th style="width: 143.466px; height: 10px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 10px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:</td>
<td style="width: 258.011px; height: 10px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &micro;m<br />3 (15 m&sup2; each)<br />484 ft&sup2; (45 m&sup2;)<br />(2)- 2&rdquo; MNPT<br />(2)- 1 1/2&rdquo; MNPT<br />(2)- to fit 2.5&rdquo; pipes</td>
</tr>
</tbody>
</table></div>
<div>
<table class="tableCenter" style="height: 71px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>Typical Dry Weight</strong></td>
<td style="text-align: center;"><strong>Typical Wet Weight</strong></td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center;">HSM45-ES-HSE15</th>
<td style="text-align: center;">228 lbs (104 kg)</td>
<td style="text-align: center;">326 lbs (148 kg)</td>
</tr>
<tr style="height: 23px;">
<th style="text-align: center;">HSM45-ES15-316</th>
<td style="text-align: center;">231 lbs (105 kg</td>
<td style="text-align: center;">329 lbs (150 kg)</td>
</tr>
</tbody>
</table></div>
</p>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features</strong></h5>
<ul>
<li>Maximum Trans Membrane Pressure (Vacuum):-6 psig (-0.41 bar)</li>
<li>Maximum Backwash Trans Membrane Pressure:2 psig (0.14 bar)</li>
<li>Maximum Instantaneous Chlorine Concentration:5,000 ppm<sup>a</sup></li>
<li>Maximum Chlorine Tolerance:742,000 ppm-hrs<sup>b</sup></li>
<li>MLSS Range8,000 &#8211; 12,000 mg/L<sup>c</sup></li>
<li>Operating Temperature Range:41 &#8211; 104&deg;F (5 &#8211; 40&deg; C)</li>
<li>Feed Water pH Range:6.0 &#8211; 8.0</li>
<li>Cleaning pH Range:1.0 &#8211; 11.0</li>
<li>Operating Mode:Outside to Inside</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Hydranautics HYDRAsub HSM45-ES-HSE15 utilzes first-rate biological treatment and MBR features that enhance the performance of industrial and municipal wastewater applications.</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Hydranautics HYDRAsub HSM45-ES-HSE15 Data Sheet" href="../../../../content/pdf/hydranautics-hydrasub-hsm45-es-hse15.pdf" target=" _blank" rel="noopener">Hydranautics HYDRAsub HSM45-ES-HSE15 Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics HYDRAsub HSM30-ES-HSE15</title>
		<link>https://aquacomponents.sa/product/hydranautics-hydrasub-hsm30-es-hse15/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:51:24 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-hydrasub-hsm30-es-hse15/</guid>

					<description><![CDATA[Hydranautics HYDRAsub HSM30-ES-HSE15 Is an immersed module designed with hollow PVDF fiber technology for utilizations demanding MBR solutions. To produce higher quality water, Hydranautics has built modules that outperform traditional activated sludge treatment processes. The higher quality water is more ideal for other treatment methods such as RO purification and decreases the footprint significantly by [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics HYDRAsub HSM30-ES-HSE15 Is an immersed module designed with hollow PVDF fiber technology for utilizations demanding MBR solutions. To produce higher quality water, Hydranautics has built modules that outperform traditional activated sludge treatment processes. The higher quality water is more ideal for other treatment methods such as RO purification and decreases the footprint significantly by eliminating the sedimentation tank and on a higher MLSS. MBR technology are generally utilized in municipal and industrial applications, including textile, food &amp; beverage, and chemical processes.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div>
<table class="tableCenter" style="height: 28px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th>&nbsp;</th>
<td style="text-align: center;"><strong>HYDRAsub&reg; &#8211; MBR </strong></td>
<td style="text-align: center;"><strong><span>HSM30 w/ HSE 15</span></strong></td>
</tr>
<tr style="height: 10px;">
<th style="width: 143.466px; height: 10px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 10px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:</td>
<td style="width: 258.011px; height: 10px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &micro;m<br />2 (15 m&sup2; each)<br />322 ft&sup2; (30 m&sup2;)<br />(2)- 2&rdquo; MNPT<br />(2)- 1 1/2&rdquo; MNPT<br />(2)- to fit 2.5&rdquo; pipes</td>
</tr>
</tbody>
</table></div>
<div>
<table class="tableCenter" style="height: 71px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>Typical Dry Weight</strong></td>
<td style="text-align: center;"><strong>Typical Wet Weight</strong></td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center;">HSM30-ES-HSE15</th>
<td style="text-align: center;">205 lbs (93 kg)</td>
<td style="text-align: center;">295 lbs (134 kg)</td>
</tr>
<tr style="height: 23px;">
<th style="text-align: center;">HSM30-ES15-316</th>
<td style="text-align: center;">207 lbs (94 kg)</td>
<td style="text-align: center;">299 lbs (136 kg)</td>
</tr>
</tbody>
</table></div>
</p>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features</strong></h5>
<ul>
<li>Maximum Trans Membrane Pressure (Vacuum):-6 psig (-0.41 bar)</li>
<li>Maximum Backwash Trans Membrane Pressure:2 psig (0.14 bar)</li>
<li>Maximum Instantaneous Chlorine Concentration:5,000 ppm<sup>a</sup></li>
<li>Maximum Chlorine Tolerance:742,000 ppm-hrs<sup>b</sup></li>
<li>MLSS Range:8,000 &#8211; 12,000 mg/L<sup>c</sup></li>
<li>Operating Temperature Range:41 &#8211; 104&deg;F (5 &#8211; 40&deg; C)</li>
<li>Feed Water pH Range:6.0 &#8211; 8.0</li>
<li>Cleaning pH Range:1.0 &#8211; 11.0</li>
<li>Operating Mode:Outside to Inside</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Hydranautics HYDRAsub HSM30-ES-HSE15Is delivers high quality MBR solutions for municipal and industrial wastewater projects.</li>
</ul>
<p align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document" align="justify"><a title="Hydranautics HYDRAsub HSM30-ES-HSE15 Data Sheet" href="../../../../content/pdf/hydranautics-hydrasub-hsm30-es-hse15.pdf" target=" _blank" rel="noopener">Hydranautics HYDRAsub HSM30-ES-HSE15 Data Sheet</a></p>
<p align="justify">
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics HYDRAsub HSM15-ES-HSE15</title>
		<link>https://aquacomponents.sa/product/hydranautics-hydrasub-hsm15-es-hse15/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:51:22 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-hydrasub-hsm15-es-hse15/</guid>

					<description><![CDATA[Hydranautics HYDRAsub HSM15-ES-HSE15 is a submerged module constructed with PVDF hollow fiber for applications that require MBR solutions. Hydranautics has developed modules to outperform more conventional activated sludge treatment in order to generate higher quality water. This better quality water is more well-suited for many processes such as RO treatment and dramatically lowers the footprint [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics HYDRAsub HSM15-ES-HSE15 is a submerged module constructed with PVDF hollow fiber for applications that require MBR solutions. Hydranautics has developed modules to outperform more conventional activated sludge treatment in order to generate higher quality water. This better quality water is more well-suited for many processes such as RO treatment and dramatically lowers the footprint by removing the sedimentation tank and working at a higher MLSS. They are most commonly used in industrial and municipal wastewater projects, as well as food &amp; beverage, chemical, textile, and several other applications.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div>
<table class="tableCenter" style="height: 28px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th>&nbsp;</th>
<td style="text-align: center;"><strong>HYDRAsub&reg; &#8211; MBR </strong></td>
<td style="text-align: center;"><strong><span>HSM15 w/ HSE15</span></strong></td>
</tr>
<tr style="height: 10px;">
<th style="width: 143.466px; height: 10px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 10px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:</td>
<td style="width: 258.011px; height: 10px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &micro;m<br />1 (15 m&sup2; each)<br />161 ft2 (15 m&sup2;)<br />(2)- 2&rdquo; MNPT<br />(2)- 1 1/2&rdquo; MNPT<br />(2)- to fit 2.5&rdquo; pipes</td>
</tr>
</tbody>
</table></div>
<div>
<table class="tableCenter" style="height: 69px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center; height: 20px; width: 139px;"><strong>Model</strong></td>
<td style="text-align: center; height: 20px; width: 149px;"><strong>Typical Dry Weight</strong></td>
<td style="text-align: center; height: 20px; width: 153px;"><strong>Typical Wet Weight</strong></td>
</tr>
<tr style="height: 30px;">
<th style="text-align: center; height: 28px; width: 139px;">HSM15-ES-HSE15</th>
<td style="text-align: center; height: 28px; width: 149px;">179 lbs (81 kg)</td>
<td style="text-align: center; height: 28px; width: 153px;">264 lbs (120 kg)</td>
</tr>
<tr style="height: 23px;">
<th style="text-align: center; height: 21px; width: 139px;">HSM15-ES15-316</th>
<td style="text-align: center; height: 21px; width: 149px;">180 lbs (82 kg)</td>
<td style="text-align: center; height: 21px; width: 153px;">267 lbs (122 kg)</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features</strong></h5>
<ul>
<li>Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)</li>
<li>Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)</li>
<li>Maximum Instantaneous Chlorine Concentration: 5,000 ppm<sup>a</sup></li>
<li>Maximum Chlorine Tolerance: 742,000 ppm-hrs<sup>b</sup></li>
<li>MLSS Range: 8,000 &#8211; 12,000 mg/L<sup>c</sup></li>
<li>Operating Temperature Range: 41 &#8211; 104&deg;F (5 &#8211; 40&deg; C)</li>
<li>Feed Water pH Range: 6.0 &#8211; 8.0</li>
<li>Cleaning pH Range: 1.0 &#8211; 11.0</li>
<li>Operating Mode: Outside to Inside</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Hydranautics HYDRAsub HSM15-ES-HSE15 utilzies cutting-edge features to further improve the working processes of industrial and municipal wastewater projects.</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM15-ES-HSE15 Data Sheet" href="../../../../content/pdf/hydranautics-hydrasub-hsm15-es-hse15.pdf" target=" _blanl" rel="noopener">Hydranautics HYDRAsub HSM15-ES-HSE15 Data Sheet</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM1500-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm1500-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:55 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm1500-es-membrane/</guid>

					<description><![CDATA[HYDRAsub HSM1500-ES Membrane technology has received global recognition as the technology of choice for the treatment of industrial and municipal effluent. HYDRAsub &#174;-MBR technology provides a reduced footprint and improved effluent output in a simple-to-serve and reliable design. Models &#160; HYDRAsub&#174; &#8211; MBR HSM1500-ES ModuleSpecifications Configuration:Fiber Orientation:Filtrate Flow:Membrane Polymer:Pore Size (nominal):Number of Elements in Module:Nominal [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>HYDRAsub HSM1500-ES Membrane technology has received global recognition as the technology of choice for the treatment of industrial and municipal effluent. HYDRAsub &reg;-MBR technology provides a reduced footprint and improved effluent output in a simple-to-serve and reliable design.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 142.557px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 268.011px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 267.102px; height: 18px;"><strong>HSM1500-ES</strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 142.557px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 268.011px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 267.102px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />60 (25 m&sup2; each)<br />16140 ft2 (1500 m&sup2;)<br />(4)- 3&rdquo; MNPT<br />(4)- 2&rdquo; MNPT<br />(2)- To fit 3&rdquo; pipe<br />3542 lbs (1610 kg)<br />5634 lbs (2555 kg)</td>
</tr>
<tr>
<th style="width: 142.557px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 268.011px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode:</td>
<td style="width: 267.102px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000-12,000 mg/L<sup>c</sup><br />41-104&deg;F (5 -40&deg;C)<br />6.0-8.0<br />1.0 &#8211; 11.0<br />Outside to Inside</td>
</tr>
<tr>
<th style="width: 142.557px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 268.011px; height: 114px;">Operating Filtrate Flux<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />CIP Chemicals:</td>
<td style="width: 267.102px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table>
<div>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM1500-ES Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm1500-es-membrane-data-sheet.pdf" target="_blank" rel="noopener">HYDRAsub HSM1500-ES Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM1000-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm1000-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:49 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm1000-es-membrane/</guid>

					<description><![CDATA[HYDRAsub &#174; provides superior-quality permeate water ideal for reverse osmosis treatment compared to traditional activated sludge treatment, and significantly reduces footprint by removing sedimentation tank and running at higher MLSS. Models &#160; HYDRAsub&#174; &#8211; MBR HSM1000-ES ModuleSpecifications Configuration:Fiber Orientation:Filtrate Flow:Membrane Polymer:Pore Size (nominal):Number of Elements in Module:Nominal Membrane Area per Module:Permeate Connections:Air Connections:Guide Pipe Connections:Typical [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<div class="first-sentence-half">
<div class="first-sentence-half">HYDRAsub &reg; provides superior-quality permeate water ideal for reverse osmosis treatment compared to traditional activated sludge treatment, and significantly reduces footprint by removing sedimentation tank and running at higher MLSS.</div>
</p></div>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 128.011px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 332.557px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 218.92px; height: 18px;"><strong>HSM1000-ES</strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 128.011px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 332.557px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 218.92px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />40 (25 m&sup2; each)<br />10760 ft2 (1000 m&sup2;)<br />(2)- 3&rdquo; MNPT<br />(2)- 3&rdquo; MNPT<br />(2)- To fit 3&rdquo; pipe<br />2398 lbs (1090 kg)<br />4226 lbs (1916 kg)</td>
</tr>
<tr>
<th style="width: 128.011px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 332.557px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode:</td>
<td style="width: 218.92px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000 &#8211; 12,000 mg/L<sup>c</sup><br />41 &#8211; 104&deg;F (5 &#8211; 40&deg;C)<br />6.0 &#8211; 8.0<br />10760 ft2 (1000 m&sup2;)<br />1.0 &#8211; 11.0<br />Outside to Inside</td>
</tr>
<tr>
<th style="width: 128.011px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 332.557px; height: 114px;">Operating Filtrate<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />OCIP Chemicals:</td>
<td style="width: 218.92px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM1000-ES Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm1000-es-membrane-data-sheet.pdf" target="_blank" rel="noopener">HYDRAsub HSM1000-ES Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM750-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm750-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:43 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm750-es-membrane/</guid>

					<description><![CDATA[HYDRAsub HSM750-ES Membrane is designed to deliver excellent quality permeate water that is desirable for reverse osmosis treatment compared to other conventional activated sludge treatment, and helps to reduce footprint by eliminating the sedimentation tank and operating at higher MLSS. Models &#160; HYDRAsub&#174; &#8211; MBR HSM750-ES ModuleSpecifications Configuration:Fiber Orientation:Filtrate Flow:Membrane Polymer:Pore Size (nominal):Number of Elements [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>HYDRAsub HSM750-ES Membrane is designed to deliver excellent quality permeate water that is desirable for reverse osmosis treatment compared to other conventional activated sludge treatment, and helps to reduce footprint by eliminating the sedimentation tank and operating at higher MLSS.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 143.466px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 277.102px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 258.011px; height: 18px;"><strong><span>HSM750-ES</span></strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 143.466px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 258.011px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />30 (25 m&sup2; each)<br />8070 ft2(750 m&sup2;)<br />(2)- 3&rdquo; MNPT<br />(2)- 3&rdquo; MNPT<br />(2)- To fit 3&rdquo; pipe<br />1716 lbs (780 kg)<br />3400 lbs (1543 kg)</td>
</tr>
<tr>
<th style="width: 143.466px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 277.102px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode</td>
<td style="width: 258.011px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000-12,000 mg/L<sup>c</sup><br />41-104&deg;F (5 -40&deg;C)<br />6.0-8.0<br />1.0 &#8211; 11.0<br />Outside to Inside</td>
</tr>
<tr>
<th style="width: 143.466px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 277.102px; height: 114px;">Operating Filtrate Flux<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />CIP Chemicals:</td>
<td style="width: 258.011px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM750-ES Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm750-es-membrane-data-sheet.pdf" target="_blank" rel="noopener">HYDRAsub HSM750-ES Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM500-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm500-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:38 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm500-es-membrane/</guid>

					<description><![CDATA[HYDRAsub HSM500-ES Membrane can be run at very high flux (34 Lmh or 20 gfd average for 20 degrees Celsius urban applications), culminating in CAPEX savings and a smaller footprint. The assisted PVDF fiber and the ease of use dyrubg operation are two significant benefits which lead to an accurate and stable product. Models &#160; [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>HYDRAsub HSM500-ES Membrane can be run at very high flux (34 Lmh or 20 gfd average for 20 degrees Celsius urban applications), culminating in CAPEX savings and a smaller footprint. The assisted PVDF fiber and the ease of use dyrubg operation are two significant benefits which lead to an accurate and stable product.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 143.466px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 277.102px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 258.011px; height: 18px;"><strong>HSM500-ES</strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 143.466px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Fiber Dimensions:<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 258.011px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />OD 0.11&#8243; (2.8mm)<br />20 (25 m&sup2; each)<br />5382 ft2 (500 m&sup2;)<br />Two- 2&rdquo; FNPT Connections<br />Two- 2&rdquo; FNPT Connections<br />To fit 2&rdquo; pipe<br />1166 lbs (530 kg)<br />2449 lbs (1111 kg)</td>
</tr>
<tr>
<th style="width: 143.466px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 277.102px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode<br />Aerator Pressure Loss @ Maximum Air Flow (excluding hydraulic head):</td>
<td style="width: 258.011px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000-12,000 mg/L<sup>c</sup><br />41-104&deg;F (5 -40&deg;C)<br />6.0-8.0<br />1.0 &#8211; 11.0<br />Outside to Inside<br />0.58 psig (0.04 bar)</td>
</tr>
<tr>
<th style="width: 143.466px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 277.102px; height: 114px;">Operating Filtrate Flux<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Nominal Air Flow:<br />Air Flow Range:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />CIP Chemicals:</td>
<td style="width: 258.011px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />90 scfm (152 Nm&sup3;/hr)<br />69 -103 scfm (117-175 Nm&sup3;/hr )<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM500-ES Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm500-es-membrane-data-sheet.pdf" target="_blank" rel="noopener">HYDRAsub HSM500-ES Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM375-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm375-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:33 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm375-es-membrane/</guid>

					<description><![CDATA[HYDRAsub HSM375-ES Membrane is designed as a high quality submerged module with PVDF hollow fiber for MBR applications. The product&#8217;s main characteristics are a high flux operation, a reduced footprint specification, a very easy method and a corrosion-resistant material for an extended service life. Models &#160; HYDRAsub&#174; &#8211; MBR HSM375-ES ModuleSpecifications Configuration:Fiber Orientation:Filtrate Flow:Membrane Polymer:Pore [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>HYDRAsub HSM375-ES Membrane is designed as a high quality submerged module with PVDF hollow fiber for MBR applications. The product&#8217;s main characteristics are a high flux operation, a reduced footprint specification, a very easy method and a corrosion-resistant material for an extended service life.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 143.466px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 277.102px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 258.011px; height: 18px;"><strong>HSM375-ES</strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 143.466px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 258.011px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />15 (25 m&sup2; each)<br />4035 ft2 (375 m&sup2;)<br />(2)- 2&rdquo; MNPT Connections<br />(2)- 2&rdquo; MNPT Connections<br />(2)- To fit 3&rdquo; pipe<br />814 lbs (370 kg)<br />1631 lbs (740 kg)</td>
</tr>
<tr>
<th style="width: 143.466px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 277.102px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode:</td>
<td style="width: 258.011px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000-12,000 mg/L<sup>c</sup><br />41-104&deg;F (5 -40&deg;C)<br />6.0-8.0<br />1.0 &#8211; 11.0<br />Outside to Inside</td>
</tr>
<tr>
<th style="width: 143.466px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 277.102px; height: 114px;">Operating Filtrate Flu<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />CIP Chemicals:</td>
<td style="width: 258.011px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics HYDRAsub HSM375-ES Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm375-es-membrane-data-sheet.pdf" target="_blank" rel="noopener">HYDRAsub HSM375-ES Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HYDRAsub HSM250-ES Membrane</title>
		<link>https://aquacomponents.sa/product/hydrasub-hsm250-es-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:42:27 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydrasub-hsm250-es-membrane/</guid>

					<description><![CDATA[Hydranautics invented and produced a special diffuser model for controlled aeration, integrated in the stainless steel enclosure. HYDRAsub HSM250-ES Membrane is ideal for applications regarding the treatment of wastewater in industrial and municipal areas. Models &#160; HYDRAsub&#174; &#8211; MBR HSM1000-ES ModuleSpecifications Configuration:Fiber Orientation:Filtrate Flow:Membrane Polymer:Pore Size (nominal):Number of Elements in Module:Nominal Membrane Area per Module:Permeate [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<p>Hydranautics invented and produced a special diffuser model for controlled aeration, integrated in the stainless steel enclosure. HYDRAsub HSM250-ES Membrane is ideal for applications regarding the treatment of wastewater in industrial and municipal areas.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<table class="tableCenter" style="height: 549px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="width: 143.466px; height: 18px;">&nbsp;</th>
<td style="height: 18px; width: 277.102px;"><strong>HYDRAsub&reg; &#8211; MBR</strong></td>
<td style="width: 258.011px; height: 18px;"><strong>HSM1000-ES</strong></td>
</tr>
<tr style="height: 218px;">
<th style="width: 143.466px; height: 218px;">
<p>Module<br />Specifications</th>
<td style="width: 277.102px; height: 218px;">Configuration:<br />Fiber Orientation:<br />Filtrate Flow:<br />Membrane Polymer:<br />Pore Size (nominal):<br />Number of Elements in Module:<br />Nominal Membrane Area per Module:<br />Permeate Connections:<br />Air Connections:<br />Guide Pipe Connections:<br />Typical Module Dry Weight:<br />Typical Module Wet Weight:</td>
<td style="width: 258.011px; height: 218px;">Submerged Membrane<br />Vertical<br />Bi-directional<br />Polyvinylidene Flouride (PVDF)<br />0.4 &mu;m<br />10 (25 m&sup2; each)<br />2690 ft2 (250 m&sup2;) (2)- 2&rdquo; MNPT<br />(2)- 2&rdquo; MNPT<br />(2)- 2&rdquo; MNPT(2)- To fit 3&rdquo; pipe<br />572 lbs (260 kg)<br />1406 lbs (637 kg)</td>
</tr>
<tr>
<th style="width: 143.466px; height: 199px;">
<p>Operating<br />Specifications</th>
<td style="width: 277.102px; height: 199px;">Maximum Trans Membrane Pressure(Vacuum):<br />Maximum Backwash Pressure:<br />Maximum Instantaneous Chlorine Concentration:<br />Maximum Chlorine Tolerance:<br />MLSS Range:<br />Operating Temperature Range:<br />Feed Water pH Range:<br />Cleaning pH Range:<br />Operating Mode:</td>
<td style="width: 258.011px; height: 199px;">-6 psig (-0.41 bar)<br />2 psig (0.14 bar)<br />5,000 ppm<sup>a</sup><br />742,000 ppm-hrs<sup>b</sup><br />8,000-12,000 mg/L<sup>c</sup><br />41-104&deg;F (5 -40&deg;C)<br />6.0-8.0<br />1.0 &#8211; 11.0<br />Outside to Inside</td>
</tr>
<tr>
<th style="width: 143.466px; height: 114px;">
<p>Typical<br />Process<br />Conditions</th>
<td style="width: 277.102px; height: 114px;">Operating Filtrate Flux<sup>&dagger;</sup>:<br />Peak Operating Flux<sup>&dagger;</sup>:<br />Chemically Enhanced Backwash (CEB) Flux:<br />CEB Chemicals:<br />Clean In Place (CIP) Flux:<br />CIP Chemicals:</td>
<td style="width: 258.011px; height: 114px;">4-20 gfd (7-34 lmh)<br />30 gfd (51 lmh)<br />2.4 gfd (4 lmh)<br />NaOCl<sup>d</sup> <br />2.4 gfd (4 lmh)<br />NaOCl or Citric Acid<sup>d</sup></td>
</tr>
</tbody>
</table></div>
<div>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Very high flux</li>
<li class="hl-custom-tab-content document">CAPEX savings</li>
<li class="hl-custom-tab-content document">Lower footprint</li>
<li class="hl-custom-tab-content document">PVDF fiber</li>
<li class="hl-custom-tab-content document">Reliable and robust product</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li class="hl-custom-tab-content document">Effluent (sewage or industrial source)</li>
<li class="hl-custom-tab-content document">Municipal applications</li>
</ul>
</p></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydrasub HSM Nitto Hydranautics Module Bioreactor Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydrasub-hsm-nitto-hydranautics-module-bioreactor-membrane.pdf" target="_blank" rel="noopener">Hydrasub HSM Nitto Hydranautics Module Bioreactor Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>