<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hydranautics 4&#8243; Seawater Membranes &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/hydranautics-4-seawater-membranes/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:36:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Hydranautics SWC6-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-swc6-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:44 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-swc6-4040-membrane/</guid>

					<description><![CDATA[When it comes to seawater desalination membranes, you can&#8217;t beat the SWC6-4040. Hydranautics seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">When it comes to seawater desalination membranes, you can&#8217;t beat the SWC6-4040. Hydranautics seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance.</p>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
</div>
<div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;" colspan="3"><strong>SWC6-4040 Specifications:</strong></th>
</tr>
<tr>
<td style="text-align: center;">&nbsp;</td>
<td style="text-align: center;"><strong>Low Pressure:</strong></td>
<td style="text-align: center;"><strong>High Flow:</strong></td>
</tr>
<tr>
<td>Permeate Flow:</td>
<td style="text-align: center;">1,250 gpd (4.7 m<sup>3</sup>/d)</td>
<td style="text-align: center;">2,500 gpd (9.5 m<sup>3</sup>/d)</td>
</tr>
<tr>
<td>Salt Rejection:</td>
<td style="text-align: center;">99.6% (99.4% min)</td>
<td style="text-align: center;">99.7% (99.5% min)</td>
</tr>
<tr>
<td>Applied Pressure:</td>
<td style="text-align: center;">600 psi (4.1 MPa)</td>
<td style="text-align: center;">800 psi (5.4 MPa)</td>
</tr>
<tr>
<td>Configuration:</td>
<td style="text-align: center;">Spiral Wound</td>
<td style="text-align: center;">&nbsp;</td>
</tr>
<tr>
<td>Membrane Polymer:</td>
<td style="text-align: center;">Composite Polyamide</td>
<td style="text-align: center;">&nbsp;</td>
</tr>
<tr>
<td>Membrane Active Area:</td>
<td style="text-align: center;">85ft<sup>2</sup> (7.9m<sup>2</sup>)</td>
<td style="text-align: center;">&nbsp;</td>
</tr>
</tbody>
</table></div>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following low pressure conditions:</strong></p>
<ul>
<li>32,000 ppm NaCl</li>
<li>600 psi (4.1 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 1000 psig (6.9 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-11 (1-13)*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Recovery for any Element: 10 %</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p align="justify">The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater Desalting</li>
<li>Broad Offering of Membrane Formulations Designed to Accommodate Varying Levels of Seawater Salinities Worldwide</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SWC6-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-swc6-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics SWC6-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SWC5-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-swc5-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:43 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-swc5-4040-membrane/</guid>

					<description><![CDATA[Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance.</p>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>SWC5-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 1,900 gpd (7.2 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.7% (Minimum 99.5%)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Nominal Membrane Area: 85 ft<sup>2</sup></li>
</ul>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>32,000 ppm NaCl</li>
<li>Applied Pressure:800 psi (5.5 MPa)</li>
<li>Operating Temperature: 77&deg;F (25&deg;C)</li>
<li>10% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 1200 psig (8.27 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>Feedwater pH Range: 3.0 &#8211; 10.0</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Recovery for any Element: 10%</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater Desalting</li>
<li>Broad offering of membrane formulations designed to accommodate varying levels of seawater salinities worldwide</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SWC5-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-swc5-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics SWC5-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SWC-4014 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-swc-4014-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:43 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-swc-4014-membrane/</guid>

					<description><![CDATA[SWC-4014 is an excellent seawater desalination membrane. All of Hydranautic&#8217;s membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance. Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">SWC-4014 is an excellent seawater desalination membrane. All of Hydranautic&#8217;s membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance. Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes.</p>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>SWC-4014 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 370gpd (1.4 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.4% (99.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 16.8 ft<sup>2</sup></li>
</ul>
<p><strong>Elements are wet tested for quality assurance using the following conditions (Data taken after 30 minutes of operation):</strong></p>
<ul>
<li>32000 PPM NaCl solution</li>
<li>800 psi (5.5 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &ndash; 7.0 pH Range</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 1,000 psig (6.9 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range &#8211; Continuous (Cleaning): 3.0 &ndash;10.0</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 4.0</li>
<li>Maximum Feed Flow: 12 GPM (45.4 l/m)</li>
<li>Minimum Ratio of Concentrate to Permeate Flow for any element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p align="justify">The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater Desalting</li>
<li>Broad Offering of Membrane Formulations Designed to Accommodate Varying Levels of Seawater Salinities Worldwide</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SWC-4014 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-swc-4014-membrane.pdf" target="_blank" rel="noopener">Hydranautics SWC-4014 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SWC-4021 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-swc-4021-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:43 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-swc-4021-membrane/</guid>

					<description><![CDATA[Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance.</p>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>SWC-4021 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 640gpd (2.4 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.4% (99.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 28.6 ft<sup>2</sup></li>
</ul>
<p><strong>Elements are wet tested for quality assurance using the following conditions (Data taken after 30 minutes of operation):</strong></p>
<ul>
<li>32000 PPM NaCl solution</li>
<li>800 psi (5.5 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &ndash; 7.0 pH Range</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 1,000 psig (6.9 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range; Continuous (Cleaning): 3.0 &ndash;10.0</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 4.0</li>
<li>Maximum Feed Flow: 12 GPM (45.4 l/m)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater Desalting</li>
<li>Broad Offering of Membrane Formulations Designed to Accommodate Varying Levels of Seawater Salinities Worldwide</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SWC-4021 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-swc-4021-membrane.pdf" target="_blank" rel="noopener">Hydranautics SWC-4021 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SWC5-LD-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-swc5-ld-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:43 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-swc5-ld-4040-membrane/</guid>

					<description><![CDATA[Lower fouling for maximum performance. Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Lower fouling for maximum performance. Hydranautics has over two decades of experience in desalination and over 1.7 million cubic meters (461 million gallons per day) of seawater treated by their SWC (seawater composite) membranes. SWC seawater desalination membranes are available in high productivity 8-inch and 4-inch elements, all offering the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance.</p>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>SWC5-LD-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 1,750 gpd (6.62 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.7% (99.5% minimum)</li>
<li>Configuration: Low Fouling Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 80ft<sup>2</sup> (7.43m<sup>2</sup>)</li>
<li>Feed Spacer: 34 mil (0.864mm) with biostatic agent</li>
</ul>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>32,000 ppm NaCl</li>
<li>800 psi (5.5 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 1200 psig (8.27 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-11 (1-13)</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Recovery for any Element: 10 %</li>
<li>Maximum Pressure Drop for Each Element: 10 psi&nbsp;</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater Desalting</li>
<li>Broad Offering of Membrane Formulations Designed to Accommodate Varying Levels of Seawater Salinities Worldwide</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SWC5-LD-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-swc5-ld-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics SWC5-LD-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
