<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hydranautics 4&#8243; Brackish Water Membranes &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/hydranautics-4-brackish-water-membranes/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:38:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Hydranautics SanRO HS2-4 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-sanro-hs2-4-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:59 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-sanro-hs2-4-membrane/</guid>

					<description><![CDATA[SanRO membranes from Hydranautics&#160;provide reliable, sanitary membrane&#160;performance in USP Classified water systems. SanRO&#8217;s unique design eliminates &#8220;dead&#160;flow&#8221; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&#160;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&#160;membrane, designed for sanitizing&#160;at 85? C. Users enjoy enhanced [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">SanRO membranes from Hydranautics&nbsp;provide reliable, sanitary membrane&nbsp;performance in USP Classified water systems. SanRO&rsquo;s unique design eliminates &ldquo;dead&nbsp;flow&rdquo; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&nbsp;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&nbsp;membrane, designed for sanitizing&nbsp;at 85? C. Users enjoy enhanced convenience&nbsp;by eliminating chemical handling and&nbsp;disposal concerns.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Specifications</strong></h5>
<div style="overflow-x: auto;" align="justify">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center; width: 109.83px;" rowspan="4"><strong>Membrane Type</strong></td>
<td style="text-align: center; width: 225.284px;" rowspan="4"><strong>Description</strong></td>
<td style="text-align: center; width: 213.466px;" colspan="5"><strong>Element Performance</strong></td>
<td style="text-align: center; width: 339.83px;" colspan="2"><strong>System Performance</strong></td>
</tr>
<tr>
<td style="text-align: center; width: 213.466px;" colspan="5"><strong>Permeate Flow and Rejection</strong></td>
<td style="text-align: center; width: 198.011px;" rowspan="3"><strong>Applied Pressure psig (Mpa)</strong></td>
<td style="text-align: center; width: 139.83px;" rowspan="3"><strong>Permeate TDS, PPM</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>8040</strong></td>
<td style="text-align: center;" colspan="2"><strong>4040</strong></td>
<td style="text-align: center;" rowspan="2"><strong>% Rej</strong></td>
</tr>
<tr>
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
</tr>
<tr>
<td style="text-align: center;">SanRO HS-4</td>
<td style="text-align: center;">High Rejection Composite</td>
<td style="text-align: center;">8,800</td>
<td style="text-align: center;">(33.3)</td>
<td style="text-align: center;">2,200</td>
<td style="text-align: center;">(8.4)</td>
<td style="text-align: center;">99.7)</td>
<td style="text-align: center;">225 (1.55)</td>
<td style="text-align: center;">6.0</td>
</tr>
<tr>
<td style="text-align: center;">SanRO HS2-4</td>
<td style="text-align: center;">High Flux, High Rejection Composite</td>
<td style="text-align: center;">11,200</td>
<td style="text-align: center;">(42.4)</td>
<td style="text-align: center;">2,800</td>
<td style="text-align: center;">(10.6)</td>
<td style="text-align: center;">99.6</td>
<td style="text-align: center;">185 (1.28)</td>
<td style="text-align: center;">8.6</td>
</tr>
</tbody>
</table></div>
</p>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Configuration: Sanitary Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Maximum Applied Pressure, psi (MPa): 600 (4.14)</li>
<li>Maximum Pressure Drop per Vessel, psi (MPa): 60 (0.41)</li>
<li>Maximum Pressure Drop per Membrane, psi (MPa): 10 (0.07)</li>
<li>Maximum Chlorine Concentration, PPM: &lt;0.1</li>
<li>Maximum Operating Temperature, &deg;F (&deg;C): 113&deg; (45&deg;)</li>
<li>Sanitizing Temperature/Pressure Max., &deg;C (psig): 85&deg; (25)</li>
<li>Operating pH Range: 3.0 &#8211; 10.0</li>
<li>Cleaning pH Range: 2.0 &#8211; 11.0</li>
</ul>
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Reduction of bacterial endotoxins and microbes</li>
<li>Opthalmic and inhalation product production</li>
<li>Reduction of TDS, TOC and colloids from high purity water</li>
<li>Removal of algae, fungi, mold, yeast and bacteria as measured in &ldquo;colony forming units &ldquo;(CFU)</li>
<li>Removal of bacteria from cell walls of polysaccharide compounds</li>
<li>Reduction of microbial growth by minimizing nutrients</li>
<li>Electronics-grade ultrapure water</li>
<li>Water for cosmetic production</li>
<li>Nutriceutical production</li>
<li>Food and beverage production</li>
<li>Container rinsing</li>
<li>Production of ultrapure or PW (Purified Water)</li>
<li>Wine de-alcoholization</li>
<li>Replacement of distillation systems, providing lower energy usage and costs</li>
</ul>
<p align="justify">
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SanRO HS2-4 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-sanro-hs2-4-membrane.pdf" target="_blank" rel="noopener">Hydranautics SanRO HS2-4 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SanRO HS-4 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-sanro-hs-4-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:58 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-sanro-hs-4-membrane/</guid>

					<description><![CDATA[SanRO membranes from Hydranautics&#160;provide reliable, sanitary membrane&#160;performance in USP Classified water systems. SanRO&#8217;s unique design eliminates &#8220;dead&#160;flow&#8221; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&#160;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&#160;membrane, designed for sanitizing&#160;at 85? C. Users enjoy enhanced [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">SanRO membranes from Hydranautics&nbsp;provide reliable, sanitary membrane&nbsp;performance in USP Classified water systems. SanRO&rsquo;s unique design eliminates &ldquo;dead&nbsp;flow&rdquo; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&nbsp;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&nbsp;membrane, designed for sanitizing&nbsp;at 85? C. Users enjoy enhanced convenience&nbsp;by eliminating chemical handling and&nbsp;disposal concerns.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5 align="justify"><strong>Specifications</strong></h5>
<div style="overflow-x: auto;" align="justify">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center; width: 109.83px;" rowspan="4"><strong>Membrane Type</strong></td>
<td style="text-align: center; width: 225.284px;" rowspan="4"><strong>Description</strong></td>
<td style="text-align: center; width: 213.466px;" colspan="5"><strong>Element Performance</strong></td>
<td style="text-align: center; width: 339.83px;" colspan="2"><strong>System Performance</strong></td>
</tr>
<tr>
<td style="text-align: center; width: 213.466px;" colspan="5"><strong>Permeate Flow and Rejection</strong></td>
<td style="text-align: center; width: 198.011px;" rowspan="3"><strong>Applied Pressure psig (Mpa)</strong></td>
<td style="text-align: center; width: 139.83px;" rowspan="3"><strong>Permeate TDS, PPM</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>8040</strong></td>
<td style="text-align: center;" colspan="2"><strong>4040</strong></td>
<td style="text-align: center;" rowspan="2"><strong>% Rej</strong></td>
</tr>
<tr>
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
</tr>
<tr>
<td style="text-align: center;">SanRO HS-4</td>
<td style="text-align: center;">High Rejection Composite</td>
<td style="text-align: center;">8,800</td>
<td style="text-align: center;">(33.3)</td>
<td style="text-align: center;">2,200</td>
<td style="text-align: center;">(8.4)</td>
<td style="text-align: center;">99.7)</td>
<td style="text-align: center;">225 (1.55)</td>
<td style="text-align: center;">6.0</td>
</tr>
<tr>
<td style="text-align: center;">SanRO HS2-4</td>
<td style="text-align: center;">High Flux, High Rejection Composite</td>
<td style="text-align: center;">11,200</td>
<td style="text-align: center;">(42.4)</td>
<td style="text-align: center;">2,800</td>
<td style="text-align: center;">(10.6)</td>
<td style="text-align: center;">99.6</td>
<td style="text-align: center;">185 (1.28)</td>
<td style="text-align: center;">8.6</td>
</tr>
</tbody>
</table></div>
</p>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Configuration: Sanitary Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Maximum Applied Pressure, psi (MPa): 600 (4.14)</li>
<li>Maximum Pressure Drop per Vessel, psi (MPa): 60 (0.41)</li>
<li>Maximum Pressure Drop per Membrane, psi (MPa): 10 (0.07)</li>
<li>Maximum Chlorine Concentration, PPM: &lt;0.1</li>
<li>Maximum Operating Temperature, &deg;F (&deg;C): 113&deg; (45&deg;)</li>
<li>Sanitizing Temperature/Pressure Max., &deg;C (psig): 85&deg; (25)</li>
<li>Operating pH Range: 3.0 &#8211; 10.0</li>
<li>Cleaning pH Range: 2.0 &#8211; 11.0</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Reduction of bacterial endotoxins and microbes</li>
<li>Opthalmic and inhalation product production</li>
<li>Reduction of TDS, TOC and colloids from high purity water</li>
<li>Removal of algae, fungi, mold, yeast and bacteria as measured in &ldquo;colony forming units &ldquo;(CFU)</li>
<li>Removal of bacteria from cell walls of polysaccharide compounds</li>
<li>Reduction of microbial growth by minimizing nutrients</li>
<li>Electronics-grade ultrapure water</li>
<li>Water for cosmetic production</li>
<li>Nutriceutical production</li>
<li>Food and beverage production</li>
<li>Container rinsing</li>
<li>Production of ultrapure or PW (Purified Water)</li>
<li>Wine de-alcoholization</li>
<li>Replacement of distillation systems, providing lower energy usage and costs</li>
</ul>
<p align="justify">
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SanRO HS-4 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-sanro-hs-4-membrane.pdf" target="_blank" rel="noopener">Hydranautics SanRO HS-4 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SanRO ESPA2-4 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-sanro-espa2-4-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:56 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-sanro-espa2-4-membrane/</guid>

					<description><![CDATA[SanRO membranes from Hydranautics provide reliable, sanitary membrane performance in USP Classified water systems. SanRO unique design eliminates &#8220;dead&#160;flow&#8221; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling. SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&#160;membrane, designed for sanitizing at 85&#176;C. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">SanRO membranes from Hydranautics provide reliable, sanitary membrane performance in USP Classified water systems. SanRO unique design eliminates &ldquo;dead&nbsp;flow&rdquo; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling. SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&nbsp;membrane, designed for sanitizing at 85&deg;C. Users enjoy enhanced convenience&nbsp;by eliminating chemical handling and disposal concerns.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;" align="justify">
<table class="tableCenter" style="height: 129px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center;" rowspan="4"><strong>Membrane Type</strong></td>
<td style="text-align: center;" rowspan="4"><strong>Description</strong></td>
<td style="text-align: center;" colspan="5"><strong>Element Performance</strong></td>
<td style="text-align: center;" colspan="2"><strong>System Performance</strong></td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center;" colspan="5"><strong>Permeate Flow and Rejection</strong></td>
<td style="text-align: center;" rowspan="3"><strong>Applied Pressure psig (Mpa)</strong></td>
<td style="text-align: center;" rowspan="3"><strong>Permeate TDS, PPM</strong></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2"><strong>8040</strong><strong><br /></strong></td>
<td style="text-align: center;" colspan="2"><strong>4040</strong><strong><br /></strong></td>
<td style="text-align: center;" rowspan="2"><strong>% Rej</strong></td>
</tr>
<tr style="height: 10px;">
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
<td style="text-align: center;">GPD</td>
<td style="text-align: center;">(m&sup3;/d)</td>
</tr>
<tr>
<td style="text-align: center;">SanRO CPA3</td>
<td style="text-align: center;">High Rejection Composite</td>
<td style="text-align: center;">10,500</td>
<td style="text-align: center;">(39.7)</td>
<td style="text-align: center;">2,600</td>
<td style="text-align: center;">(9.8)</td>
<td style="text-align: center;">99.7</td>
<td style="text-align: center;">195 (1.35)</td>
<td style="text-align: center;">7.4</td>
</tr>
<tr>
<td style="text-align: center;">SanRO ESPA2-4</td>
<td style="text-align: center;">High Rejection Energy Saver</td>
<td style="text-align: center;">13,000</td>
<td style="text-align: center;">(49.2)</td>
<td style="text-align: center;">3,300</td>
<td style="text-align: center;">(12.5)</td>
<td style="text-align: center;">99.7</td>
<td style="text-align: center;">165 (1.14)</td>
<td style="text-align: center;">9.5</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Configuration: Sanitary Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Maximum Applied Pressure, psi (MPa): 600 (4.14)</li>
<li>Maximum Pressure Drop per Vessel, psi (MPa): (0.41)</li>
<li>Maximum Pressure Drop per Membrane, psi (MPa): 10 (0.07)</li>
<li>Maximum Chlorine Concentration, PPM: &lt;0.1</li>
<li>Maximum Operating Temperature, &deg;F (&deg;C): 113&deg; (45&deg;)</li>
<li>Operating pH Range: 3.0 &#8211; 10.0</li>
<li>Cleaning pH Range: 2.0 &#8211; 11.0</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>High volume pharmaceutical rinsing</li>
<li>Cosmetic formulations</li>
<li>Container rinsing</li>
<li>Cleaning of fermentation equipment, enzymes, polypeptides, blood products, antibiotics, clarification, desalting, concentration.</li>
<li>Buffer ex-change in the manufacture of proteins, and other biotechnology products.</li>
</ul>
<p align="justify">
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SanRO ESPA2-4 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-sanro-espa2-4-membrane.pdf" target="_blank" rel="noopener">Hydranautics SanRO ESPA2-4 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics SanRO CPA3-4 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-sanro-cpa3-4-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:55 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-sanro-cpa3-4-membrane/</guid>

					<description><![CDATA[SanRO membranes from Hydranautics&#160;provide reliable, sanitary membrane&#160;performance in USP Classified water systems. SanRO&#8217;s unique design eliminates &#8220;dead&#160;flow&#8221; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&#160;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&#160;membrane, designed for sanitizing&#160;at 85? C. Users enjoy enhanced [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">SanRO membranes from Hydranautics&nbsp;provide reliable, sanitary membrane&nbsp;performance in USP Classified water systems. SanRO&rsquo;s unique design eliminates &ldquo;dead&nbsp;flow&rdquo; areas &#8211; potential breeding grounds for bacterial growth &#8211; and ensures maximum ion removal with minimal fouling.&nbsp;SanRO-HS, and the new SanRO-HS2, provide all the benefits of SanRO in a heatsanitizable&nbsp;membrane, designed for sanitizing&nbsp;at 85? C. Users enjoy enhanced convenience&nbsp;by eliminating chemical handling and&nbsp;disposal concerns.</p>
<p align="justify"><span></p>
<div class="tabtitle" id="custom-specifications">Models</div>
<p></span></p>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;" align="justify"> </p>
<table class="tableCenter" style="width: 1030px; height: 118px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<td style="text-align: center; width: 119.83px; height: 64px;" rowspan="4"><strong>Membrane Type</strong></td>
<td style="text-align: center; width: 194.375px; height: 64px;" rowspan="4"><strong>Description</strong></td>
<td style="text-align: center; width: 321.648px; height: 18px;" colspan="5"><strong>Element Performance</strong></td>
<td style="text-align: center; width: 384.375px; height: 18px;" colspan="2"><strong>System Performance</strong></td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; width: 321.648px; height: 18px;" colspan="5"><strong>Permeate Flow and Rejection</strong></td>
<td style="text-align: center; width: 224.375px; height: 46px;" rowspan="3"><strong>Applied Pressure psig (Mpa)</strong></td>
<td style="text-align: center; width: 158.011px; height: 46px;" rowspan="3"><strong>Permeate TDS, PPM</strong></td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; width: 132.557px; height: 18px;" colspan="2"><strong>8040</strong><strong><br /></strong></td>
<td style="text-align: center; width: 139.83px; height: 18px;" colspan="2"><strong>4040</strong><strong><br /></strong></td>
<td style="text-align: center; width: 45.2841px; height: 28px;" rowspan="2"><strong>% Rej</strong></td>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 78.9205px; height: 10px;">GPD</td>
<td style="text-align: center; width: 51.6477px; height: 10px;">(m&sup3;/d)</td>
<td style="text-align: center; width: 88.0114px; height: 10px;">GPD</td>
<td style="text-align: center; width: 49.8295px; height: 10px;">(m&sup3;/d)</td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; width: 119.83px; height: 18px;">SanRO CPA3-4</td>
<td style="text-align: center; width: 194.375px; height: 18px;">High Rejection Composite</td>
<td style="text-align: center; width: 78.9205px; height: 18px;">10,500</td>
<td style="text-align: center; width: 51.6477px; height: 18px;">(39.7)</td>
<td style="text-align: center; width: 88.0114px; height: 18px;">2,600</td>
<td style="text-align: center; width: 49.8295px; height: 18px;">(9.8)</td>
<td style="text-align: center; width: 45.2841px; height: 18px;">99.7</td>
<td style="text-align: center; width: 224.375px; height: 18px;">195 (1.35)</td>
<td style="text-align: center; width: 158.011px; height: 18px;">7.4</td>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 119.83px; height: 36px;">SanRO ESPA2-4</td>
<td style="text-align: center; width: 194.375px; height: 36px;">High Rejection Energy Saver</td>
<td style="text-align: center; width: 78.9205px; height: 36px;">13,000</td>
<td style="text-align: center; width: 51.6477px; height: 36px;">(49.2)</td>
<td style="text-align: center; width: 88.0114px; height: 36px;">3,300</td>
<td style="text-align: center; width: 49.8295px; height: 36px;">(12.5)</td>
<td style="text-align: center; width: 45.2841px; height: 36px;">99.7</td>
<td style="text-align: center; width: 224.375px; height: 36px;">165 (1.14)</td>
<td style="text-align: center; width: 158.011px; height: 36px;">9.5</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Configuration: Sanitary Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Maximum Applied Pressure, psi (MPa): 600 (4.14)</li>
<li>Maximum Pressure Drop per Vessel, psi (MPa): 60 (0.41)</li>
<li>Maximum Pressure Drop per Membrane, psi (MPa): 10 (0.07)</li>
<li>Maximum Chlorine Concentration, PPM: &lt;0.1</li>
<li>Maximum Operating Temperature, &deg;F (&deg;C): 113&deg; (45&deg;)</li>
<li>Operating pH Range: 3.0 &#8211; 10.0</li>
<li>Cleaning pH Range: 2.0 &#8211; 11.0</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>High volume pharmaceutical rinsing</li>
<li>Cosmetic formulations</li>
<li>Container rinsing</li>
<li>Cleaning of fermentation equipment, enzymes, polypeptides, blood products, antibiotics, clarification, desalting, concentration.</li>
<li>Buffer ex-change in the manufacture of proteins, and other biotechnology products.</li>
</ul>
<p><span></span></p>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics SanRO CPA3-4 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-sanro-cpa3-4-membrane.pdf" target="_blank" rel="noopener">Hydranautics SanRO CPA3-4 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA4-LD-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa4-ld-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:46 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa4-ld-4040-membrane/</guid>

					<description><![CDATA[ESPA4 membranes require ultra-low pressures without compromising standards for high flux and high salt rejection. ESPA4 membrane has been commonly used in drinking water production from well and surface waters in the water treatment industry. It is widely accepted due to significant operational cost savings associated with their use. Due to their ultra-low feed pressure [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA4 membranes require ultra-low pressures without compromising standards for high flux and high salt rejection. ESPA4 membrane has been commonly used in drinking water production from well and surface waters in the water treatment industry. It is widely accepted due to significant operational cost savings associated with their use.</p>
<p align="justify">Due to their ultra-low feed pressure requirement, ESPA4 membranes have been accepted as a standard in the second pass of a two pass reverse osmosis systems.</p>
<p align="justify">ESPA4-LD are ultra-low pressure brackish water membranes that use patented Low Differential LDTM technology designed to minimize colloidal fouling.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>ESPA4-LD-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 2,350 gpd (8.90 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.2% (99.0% minimum)</li>
<li>Type Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 80 ft<sup>2</sup> (7.4 m<sup>2</sup>)</li>
<li>Feed Spacer: 34 mil (0.864 mm)</li>
</ul>
<p align="justify"><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>500 ppm NaCl solution</li>
<li>100 psi (0.7 MPa) Applied Pressure</li>
<li>77 &deg;F (25 &deg;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.14 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113 &deg;F (45 &deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-10 (1-12)</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 15 psi</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul>
<p align="justify">
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA4-LD-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa4-ld-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA4-LD-4040 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA3-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa3-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:44 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa3-4040-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use.&#160; The growing family of ESPA membranes continue to meet the [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use.&nbsp;</p>
<p align="justify">The growing family of ESPA membranes continue to meet the ever-increasing demands of the water treatment industry. ESPA2 offers unparalleled performance for your industrial and commercial water treatment needs. There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings for high productivity and salt rejection.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>ESPA3-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 3000 gpd (11.4 m<sup>3</sup>/d)</li>
<li>Salt Rejection (nominal) 98.5 %</li>
<li>Type Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Nominal Membrane Area: 85 ft<sup>2</sup></li>
</ul>
<p align="justify"><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.05 MPa) Applied Pressure</li>
<li>77 &deg;F (25 &deg;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul>
<p align="justify">&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5 align="justify"><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.16 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113 &deg;F (45 &deg;C)</li>
<li>Feedwater pH Range: 3.0 &#8211; 10.0</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Ratio of Concentrate to permeate Flow for any Element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p align="justify">&nbsp;</p>
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul>
<p align="justify">&nbsp;</p>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA3-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa3-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA3-4040 Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics CPA-4040E Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-cpa-4040e-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:38:36 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-cpa-4040e-membrane/</guid>

					<description><![CDATA[CPA RO membranes are regarded as the industry standard for all critical high purity applications &#8211; from pharmaceutical to power industry. CPA lines of spiral-wound RO membranes are available in a variety of sizes and deliver unmatched performance with the highest salt rejection rates for brackish water applications. High throughput, efficiency and cost-effectiveness make CPA [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">CPA RO membranes are regarded as the industry standard for all critical high purity applications &ndash; from pharmaceutical to power industry.</p>
<p align="justify">CPA lines of spiral-wound RO membranes are available in a variety of sizes and deliver unmatched performance with the highest salt rejection rates for brackish water applications. High throughput, efficiency and cost-effectiveness make CPA membranes the best high-rejection brackish water RO membranes in the industry.</p>
<p align="justify">Because of its exceptionally high salt rejection, CPA membranes are used in power generation, pharmaceutical, electronics and semiconductor industry.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>CPA-4040E Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 2,250 gpd (8.5 m<sup>3</sup>/d)</li>
<li>Salt Rejection : 99.5% (99.2% minimum)</li>
<li>Feed Spacer: 34 mil (0.864 mm)</li>
<li>Configuration:&nbsp;Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 65 ft<sup>2</sup> (6.04 m<sup>2</sup>)</li>
</ul>
<p align="justify"><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>225 psi (1.55 MPa) Applied Pressure</li>
<li>77 &deg;F (25 &deg;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.14 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113 &deg;F (45 &deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-10 (1-12)*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Maximum Pressure Drop for Each Element: 15 psi</li>
<li>Dry Element Temperature Storage -40 &deg;C to 40 &deg;C (-40&deg;F to 104&deg;F)</li>
<li>Wet Element Temperature Storage 1 &deg;C to 35 &deg;C (33&deg;F to 95&deg;F)</li>
</ul>
<p align="justify"><span></span></p>
<p align="justify"><span></p>
<div class="tabtitle" id="custom-usage">Applications</div>
<p></span></p>
<ul>
<li><span>Municipal/Industrial Surface and Wastewaters</span></li>
<li><span>Difficult Feedwaters Requiring Significant Pretreatment</span></li>
</ul>
<p align="justify"><span></span></p>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics CPA-4040E Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-cpa-4040e-membrane.pdf" target="_blank" rel="noopener">Hydranautics CPA-4040E Membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA2-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa2-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:37:14 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa2-4040-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available. The growing family of ESPA [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available.</p>
<p align="justify">The growing family of ESPA RO membranes continue to meet the ever-increasing demands of the water treatment industry. ESPA2-4040 offers unparalleled performance for your industrial and commercial water treatment needs. There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings for high productivity and salt rejection.</p>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>ESPA2-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 1,900 gpd (7.19 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.6% (99.4% minimum)</li>
<li>Configuration: Low Fouling Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 85ft<sup>2</sup>&nbsp;(7.90m<sup>2</sup>)</li>
<li>Feed Spacer: 34 mil (0.864 mm) with biostatic agent</li>
</ul>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.05 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul>
<p>Notice: Permeate flow for individual elements may vary + or &#8211; 15 percent. &nbsp;All membrane elements are supplied with a brine seal, interconnector, and o-rings. &nbsp;Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box. &nbsp;All elements are guaranteed 99.4% minimum rejection.</p>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.16 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-11 (1-13)</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any Element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more details on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA2-4040 Membrane Data Sheet" href="https://www.pureaqua.com/content/pdf/hydranautics-espa2-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA2-4040 Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA1-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa1-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:40 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa1-4040-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available When it comes to energy-saving [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available</p>
<p align="justify">When it comes to energy-saving polyamide membranes, you can&#8217;t beat the ESPA1-4040. There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings. The world&#8217;s leading high productivity, energy-saving polyamide membrane is the growing family of ESPA RO membranes. They continue to meet the ever-increasing demands of the water treatment industry. Industrial users worldwide have made ESPA their first choice for high productivity and salt rejection.</p>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>ESPA1-4040 Specifications</strong></h5>
<ul>
<li>Permeate Flow: 2600 gpd (9.8 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.3% (99.0% Minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 85ft<sup>2</sup>&nbsp;(7.9m<sup>2</sup>)</li>
</ul>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions (Data taken after 30 minutes of operation):</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.05 MPa) Applied Pressure</li>
<li>77&ordm;F (25&ordm;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.16 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-10 (1-12)*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any Element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA1-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa1-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA1-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA4-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa4-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:40 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa4-4040-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available. There&#8217;s an ESPA solution to [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available.</p>
<p align="justify">There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings.&nbsp;For consistently high performance and long life, go with the ESPA4-4040.&nbsp;The growing family of ESPA RO membranes continue to meet the ever-increasing demands of the water treatment industry. Industrial users worldwide have made ESPA their first choice for high productivity and salt rejection.</p>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>ESPA4-4040 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 2,500 gpd (9.46 m<sup>3</sup>/d)</li>
<li>Salt Rejection: 99.2% (99.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 85ft<sup>2</sup>&nbsp;(7.9m<sup>2</sup>)</li>
</ul>
<p><strong>The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:</strong></p>
<ul>
<li>500 PPM NaCl solution</li>
<li>100 psi (0.7 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>15% Permeate Recovery</li>
<li>6.5 &#8211; 7.0 pH Range</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 600 psig (4.16 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning): 2-10 (1-12)*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 5.0</li>
<li>Maximum Feed Flow: 16 GPM (3.6 m<sup>3</sup>/h)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any Element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA4-4040 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa4-4040-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA4-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>