<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hydranautics 2.5&#8243; Brackish Water Membranes &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/hydranautics-2-5-brackish-water-membranes/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:36:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Hydranautics ESPA-2540 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa-2540-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:39 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa-2540-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available. The ESPA-2540 can meet your [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available.</p>
<p align="justify">The ESPA-2540 can meet your industrial or commercial water treatment standards.&nbsp;There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings.&nbsp;For high productivity and salt rejection,&nbsp;the industrial user&#8217;s first choice is&nbsp;the growing family of ESPA (Energy-Saving Polyamide) RO membranes that continue to meet the ever-increasing demands of the water treatment industry.</p>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>ESPA-2540 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 750 gpd (2.84m<sup>3)</sup></li>
<li>Salt Rejection 99.4% (98.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 25.5ft<sup>2</sup></li>
</ul>
<p><strong>Elements are wet tested for quality assurance using the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.03 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &ndash; 7.0 pH Range</li>
<li>(Data taken after 30 minutes of operation)</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 300 psig (2.1 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range, Continuous (Cleaning) 3.0 &ndash;10.0*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 4.0</li>
<li>Maximum Feed Flow: 6 GPM (23 l/m)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p align="justify">The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA-2540 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa-2540-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA-2540 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA-2514 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa-2514-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:39 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa-2514-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available. The ESPA-2514 offers unparalleled performance [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available.</p>
<p align="justify">The ESPA-2514 offers unparalleled performance when it comes to your commercial or industrial water treatment needs. Industrial users worldwide have made ESPA their first choice for high productivity and salt rejection because the growing family of ESPA (Energy-Saving Polyamide) RO membranes continue to meet the ever-increasing demands of the water treatment industry.</p>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>ESPA-2514 Specifications</strong></h5>
<ul>
<li>Permeate Flow: 250 gpd (0.9m<sup>3</sup>/d)</li>
<li>Salt Rejection : 99.4% (98.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 5.1ft<sup>2</sup></li>
</ul>
<p><strong>Elements are wet tested for quality assurance using the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.03 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &ndash; 7.0 pH Range</li>
<li>(Data taken after 30 minutes of operation)</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits</strong></h5>
<ul>
<li>Application Data* Maximum Applied Pressure: 300 psig (2.1 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg;F (45&deg;C)</li>
<li>pH Range; Continuous (Cleaning): 3.0 &ndash;10.0</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 4.0</li>
<li>Maximum Feed Flow: 6 GPM (23 l/m)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any element: 5:1</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p>The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light industrial</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Hydranautics ESPA-2514 Membrane" href="https://www.pureaqua.com/content/pdf/hydranautics-espa-2514-membrane.pdf" target="_blank" rel="noopener">Hydranautics ESPA-2514 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydranautics ESPA-2521 Membrane</title>
		<link>https://aquacomponents.sa/product/hydranautics-espa-2521-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:36:39 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/hydranautics-espa-2521-membrane/</guid>

					<description><![CDATA[ESPA&#174; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&#174; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&#8221; and 8&#8221; configurations available. For consistently high performance and [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">ESPA&reg; (Energy Saving Polyamide) elements achieve high flux/lower pressure without compromising standards for high rejection. Since its introduction in the late 1990s, the ESPA&reg; membrane has gained wide acceptance in the water treatment industry due to the significant operational cost savings associated with their use. 4&rdquo; and 8&rdquo; configurations available.</p>
<p align="justify">For consistently high performance and long life, go with the ESPA 2521.&nbsp;Industrial users worldwide have made ESPA their first choice for high productivity and salt rejection.&nbsp;The growing family of ESPA RO membranes continue to meet the ever-increasing demands of the water treatment industry.&nbsp;There&#8217;s an ESPA solution to satisfy even the most challenging water treatment needs with exceptional performance, productivity and savings. ESPA is the world&#8217;s leading high productivity, energy-saving polyamide membrane.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>ESPA-2521 Specifications:</strong></h5>
<ul>
<li>Permeate Flow: 350 gpd (1.3 m<sup>3</sup>)</li>
<li>Salt Rejection: 99.4% (98.0% minimum)</li>
<li>Configuration: Spiral Wound</li>
<li>Membrane Polymer: Composite Polyamide</li>
<li>Membrane Active Area: 9.9 ft<sup>2</sup></li>
</ul>
<p><strong>Elements are wet tested for quality assurance using the following conditions:</strong></p>
<ul>
<li>1500 PPM NaCl solution</li>
<li>150 psi (1.03 MPa) Applied Pressure</li>
<li>77&deg;F (25&deg;C) Operating Temperature</li>
<li>10% Permeate Recovery</li>
<li>6.5 &ndash; 7.0 pH Range</li>
<li>(Data taken after 30 minutes of operation)</li>
</ul>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<h5><strong>Standard Operating Limits:</strong></h5>
<ul>
<li>Maximum Applied Pressure: 300 psig (2.1 MPa)</li>
<li>Maximum Chlorine Concentration: &lt; 0.1 PPM</li>
<li>Maximum Operating Temperature: 113&deg; F (45&deg;C)</li>
<li>pH Range; Continuous (Cleaning): 3.0 &ndash;10.0*</li>
<li>Maximum Feedwater Turbidity: 1.0 NTU</li>
<li>Maximum Feedwater SDI (15 mins): 4.0</li>
<li>Maximum Feed Flow: 6 GPM (23 l/m)</li>
<li>Minimum Ratio of Concentrate to&nbsp;Permeate Flow for any element: 5:1&gt;</li>
<li>Maximum Pressure Drop for Each Element: 10 psi</li>
</ul>
<p align="justify">The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.</p>
</p></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Municipal Potable and Wastewater Plants</li>
<li>Bottling Operations</li>
<li>Light Industrial</li>
</ul></div>