<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fleck Control Valves &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/fleck-control-valves/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:48:19 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>Fleck  NXT2 Control Timer</title>
		<link>https://aquacomponents.sa/product/fleck-nxt2-control-timer/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:48:19 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-nxt2-control-timer/</guid>

					<description><![CDATA[Fleck NXT2 Control Timer is a well-built industrial &#38; commercial water softener valve with cutting-edge NXT digital control and technology, including a electronic meter. Other product features provided include: Uses 2 time-proven hydraulically-led pistons for automatic service flow and regenerative abilities Utilized with singular and multiple tank systems Backwashes water softener tanks of up to [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Fleck NXT2 Control Timer is a well-built industrial &amp; commercial water softener valve with cutting-edge NXT digital control and technology, including a electronic meter. Other product features provided include:</p>
<ul>
<li>Uses 2 time-proven hydraulically-led pistons for automatic service flow and regenerative abilities</li>
<li>Utilized with singular and multiple tank systems</li>
<li>Backwashes water softener tanks of up to 36&#8243; diameter</li>
<li>Constant flow rate of 106 GPM</li>
<li>Brass that is made without lead for enhanced ruggedness and stability</li>
</ul>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p align="justify"><strong>REGENERATION TYPE</strong></p>
<ul>
<li>Meter Delayed Fixed Reserve</li>
<li>Meter Immediate</li>
<li>Remote Signal Start Immediate</li>
<li>Time Clock Delayed</li>
</ul>
<p align="justify"><strong>REGENERATION TYPE</strong></p>
<ul>
<li>Downflow</li>
<li>Upflow Fill First</li>
<li>Upflow Brine First</li>
</ul>
<p align="justify"><strong>ELECTRICAL RATING</strong></p>
<ul>
<li>24V DC Power Supplies</li>
<li>100V-240V AC input; 24V DC output</li>
</ul>
<p align="justify"><strong>GENERIC METER GUIDELINES</strong></p>
<ul>
<li>Open collector output</li>
<li>Pulse rate generated must not exceed 100 pulses per second (100Hz) or 6,000 pulses per minute</li>
<li>Support for meter outputs in the range of 1-255 gallons (25.5m3) for every 1-255 pulses</li>
<li>Meter must operate at 5 VDC</li>
</ul>
<p align="justify"></p>
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>On-screen multilingual support: English, Fran&Ccedil;ais, Deutsch, Italiano, Espa&ntilde;ol, Nederlands, Portugu&ecirc;s</li>
<li>Time of day super capacitor backup for 12-hour power loss</li>
<li>2 to 4 line scrolling text OLED display, high contrast easy to read in low light conditions and at a distance</li>
<li>Full functional user interface with easy programming allowing forward and backwards menu navigation</li>
<li>Network two to eight valves via CAT5 or better cables</li>
<li>LED Status Indicator <br />&#8211; Blue: In Service <br />&#8211; Flashing Blue: Regeneration Queued <br />&#8211; Green: Regeneration <br />&#8211; Flashing Green: Standby <br />&#8211; Red: Error condition present</li>
<li>Two Programmable Auxiliary relay outputs <br />&#8211; Time-based <br />&#8211; Volume based (Chemical pump) <br />&#8211; Alarm-based <br />&#8211; Cycle-based <br />&#8211; Standby</li>
<li>Remote input <br />&#8211; Remote Lockout <br />&#8211; Remote Regeneration</li>
<li>Easy installation with plug-in wiring harnesses</li>
<li>Assistance Name and Phone Number contact fields</li>
<li>Error Log History</li>
<li>Water Usage Daily (up to 13 weeks)</li>
<li>Push Settings</li>
<li>Capacitive Touch buttons</li>
<li>Two Regeneration Lockout Windows</li>
<li>Reset to factory default settings or from savable custom settings</li>
<li>Full calendar display</li>
<li>Master Programming Lockout <br />&#8211; Code-based <br />&#8211; Time-based <br />&#8211; Delayed</li>
<li>Icons for easy system status identification</li>
<li>Dynamic network addressing</li>
<li>Diagnostics <br />&#8211; Real-time Flow Rate <br />&#8211; Peak Flow Rate (can be reset) <br />&#8211; Totalizer (can be reset) <br />&#8211; Reserve Capacity <br />&#8211; Use Since Last Regeneration <br />&#8211; Last Regeneration <br />&#8211; Identifiable Software Version <br />&#8211; Total Number of Regenerations <br />&#8211; Regeneration Interval <br />&#8211; Last Settings Change <br />&#8211; Error Log History <br />&#8211; Average Daily Usage <br />(per weekday, 3 month history)</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Ideal for most filter applications up to 42&#8243;</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document"><a title="Fleck NXT2 Control Timer Data Sheet" href="../../../../content/pdf/fleck-nxt2-control-timer.pdf" target="_blank" rel="noopener">Fleck NXT2 Control Timer Data Sheet</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 5812 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-5812-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:48:18 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-5812-control-valve/</guid>

					<description><![CDATA[The Fleck 5812 control valve is generally used as a solution for various water softening and filtration applications. It has desirable features incorporates to imrpove the performance of these systems such as superior flexibility, simple design and low maintenance costs. This valve is produced in the United States and distributed worldwide. Fleck 5812 The Fleck [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The Fleck 5812 control valve is generally used as a solution for various water softening and filtration applications. It has desirable features incorporates to imrpove the performance of these systems such as superior flexibility, simple design and low maintenance costs.</p>
<p align="justify">This valve is produced in the United States and distributed worldwide.</p>
<h4 align="justify"><strong>Fleck 5812</strong></h4>
<p align="justify">The Fleck 5812 commecial valve is rienforced with regenerative capabilities and an optical sensor for precise cycle positioning. Power outages will not hinder the operation as a result of programmed saved in memory. Reliability and productivity are guaranteed throughout the systems using these high quality Fleck valves.&nbsp;</p>
<h5 align="justify"><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li>Specify the valve needed is for back wash filter or water softener.</li>
<li>Specify the flow rate needed for your application</li>
<li>Specify the size of tank being used when&nbsp;<em>ordering to</em>&nbsp;ensure proper flow restrictor sizing.</li>
<li>Fleck valve has different option, please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div>&nbsp;</div>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 46px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 1060.74px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 351.648px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 352.557px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 352.557px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 351.648px;">Fiber Reinforced Polymer</td>
<td style="text-align: center; height: 18px; width: 352.557px;">3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</td>
<td style="text-align: center; height: 18px; width: 352.557px;">5</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</p></div>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 163px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; width: 1063.47px; height: 18px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone 2.5 Base</strong></th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; width: 264.375px; height: 18px;"><strong>Piston</strong></th>
<th style="text-align: center; width: 264.375px; height: 18px;"><strong>Downflow</strong></th>
<th style="text-align: center; width: 264.375px; height: 18px;"><strong>Upflow</strong></th>
<th style="text-align: center; width: 264.375px; height: 18px;"><strong>Filter</strong></th>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 264.375px; height: 36px;">Continuous<br />(15 psi drop)</td>
<td style="text-align: center; width: 264.375px; height: 36px;">43 GPM<br />9.9 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">39 GPM<br />8.9 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">31 GPM<br />8.4 m&sup3;/hr</td>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 264.375px; height: 36px;">Peak<br />(25 psi drop)</td>
<td style="text-align: center; width: 264.375px; height: 36px;">56 GPM<br />12.7 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">51 GPM<br />11.9 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">47 GPM<br />10.7 m&sup3;/hr</td>
</tr>
<tr style="height: 19px;">
<td style="text-align: center; width: 264.375px; height: 19px;">Cv<br />(flow at 1 psi drop)</td>
<td style="text-align: center; width: 264.375px; height: 19px;">11.2</td>
<td style="text-align: center; width: 264.375px; height: 19px;">10.1</td>
<td style="text-align: center; width: 264.375px; height: 19px;">9.4</td>
</tr>
<tr style="height: 36px;">
<td style="text-align: center; width: 264.375px; height: 36px;">Max. Backwash<br />(25 psi drop)</td>
<td style="text-align: center; width: 264.375px; height: 36px;">33 GPM<br />7.5 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">36 GPM<br />8.1 m&sup3;/hr</td>
<td style="text-align: center; width: 264.375px; height: 36px;">45 GPM<br />9.9 m&sup3;/hr</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone &#8211; 4&#8243; Base</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Piston</strong></th>
<th style="text-align: center; width: 170px;"><strong>Downflow</strong></th>
<th style="text-align: center; width: 170px;"><strong>Upflow</strong></th>
<th style="text-align: center; width: 170px;"><strong>Filter</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Continuous<br />(15 psi drop)</td>
<td style="text-align: center; width: 170px;">45 GPM<br />10.3 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">40 GPM<br />9.1 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">38 GPM<br />8.7 m&sup3;/hr</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Peak<br />(25 psi drop)</td>
<td style="text-align: center; width: 170px;">59 GPM<br />13.3 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">52 GPM<br />11.7 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">50 GPM<br />11.3 m&sup3;/hr</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Cv<br />(flow at 1 psi drop)</td>
<td style="text-align: center; width: 170px;">11.7</td>
<td style="text-align: center; width: 170px;">10.3</td>
<td style="text-align: center; width: 170px;">9.9</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Max. Backwash<br />(25 psi drop)</td>
<td style="text-align: center; width: 170px;">34 GPM<br />7.8 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">36 GPM<br />8.2 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">45 GPM<br />10.2 m&sup3;/hr</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Both</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">SXT: 0 &#8211; 199 minutes per cycle<br />XTR2: 0 &#8211; 240 min/cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 49px; width: 1170px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1166.19px;" colspan="3">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 342.557px; height: 10px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 10px; width: 821.648px;" colspan="2"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<th style="text-align: center; width: 342.557px; height: 10px;">1-1/4&#8243; Turbine:</th>
<th style="text-align: center; width: 421.648px; height: 10px;">SXT:</th>
<th style="text-align: center; width: 398.011px; height: 10px;">3XTR2:</th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; height: 11px; width: 342.557px;">2 &#8211; 40 GPM &plusmn; 5%<br />(0.45 &#8211; 49 m&sup3;/h)</td>
<td style="text-align: center; width: 421.648px; height: 11px;">1 &#8211; 999,900 gal<br />(0 &#8211; 3,785 m&sup3;)</td>
<td style="text-align: center; width: 398.011px; height: 11px;">1 &#8211; 9,999,999 gal<br />(0 &#8211; 378,541 m&sup3;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 142.557px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 141.648px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 201.648px; height: 13px;"><strong>Injector brine system</strong></th>
<th style="text-align: center; width: 163.466px; height: 13px;"><strong>Brine line</strong></th>
<th style="text-align: center; width: 224.375px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 193.466px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 142.557px; height: 10px;">1.05&#8243; O.D.</td>
<td style="text-align: center; width: 141.648px; height: 10px;">1/2&#8243; NPTF</td>
<td style="text-align: center; width: 201.648px; height: 10px;">1610 &#8211; 3/8&#8243;</td>
<td style="text-align: center; width: 163.466px; height: 10px;">3/8&#8243;</td>
<td style="text-align: center; width: 224.375px; height: 10px;">2.5&#8243; &#8211; 8 NPSM</td>
<td style="text-align: center; width: 193.466px; height: 10px;">12&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="4"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">12 Volts DC</td>
<td style="text-align: center; width: 319.83px; height: 10px;">12 lbs</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">34 &#8211; 110&deg;F (1 &#8211; 43&deg;C)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 5px;" width="1103" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1098.92px;" colspan="5"><strong>Typical Applications</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 544px;"><strong>Water softener</strong></th>
<th style="text-align: center; width: 544px;"><strong>Filters</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 544px;">8 &#8211; 21&#8243; diameter</td>
<td style="text-align: center; width: 544px;">Filters 8 &#8211; 21&#8243; diameter</td>
</tr>
</tbody>
</table></div>
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards</p>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Fiber-reinforced polymer valve body for superior strength and durability, non-corrosive, and UV-resistant</li>
<li>Continuous service flow rate of 43 GPM with a backwash of 33 GPM</li>
<li>Backwash capability accommodates softener tanks up to 24&#8243; and filters up to 24&#8243; in diameter</li>
<li>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system</li>
<li>Time-tested, hydraulically-balanced piston for service and regeneration</li>
<li>Optical sensor for precision cycle positioning</li>
<li>Soft water refill for a cleaner brine tank</li>
<li>Designed with double backwash for reduced hardness leakage</li>
<li>Diagnostics for historical valve performance</li>
<li>Programming stored in memory and will not be lost due to power outages</li>
</ul>
<h5><strong>Options:</strong></h5>
<ul class="unIndentedList">
<li>Filter or softener control valves</li>
<li>Downflow co-current or upflow counter-current regeneration</li>
<li>Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</li>
<li>Fiber-reinforced polymer or stainless steel bypass valve</li>
<li>Variable reserve for increased efficiency</li>
<li>Programmable regeneration types for increased flexibility</li>
<li>Three color bezel options of black, silver, or blue</li>
<li><strong>XTR2</strong>&#8211; Premium touch screen LCD display with two programmable relay outputs for both normally opened and normally closed contacts</li>
<li><strong>SXT</strong>-Large LCD display and user-selectable time clock or metered function; usable for filtration and softener systems</li>
</ul>
<p></p>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Commercial Softeners</li>
<li>Commercial Media Filters</li>
<li>Commercial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 5812 Spec Sheet" href="../../../../content/pdf/fleck-5812-control-valve.pdf" target="_blank" rel="noopener">Fleck 5812 Spec Sheet</a> <br /><a title="Fleck 5800XTR2 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-5800xtr2-service-manual.pdf" target="_blank" rel="noopener">Fleck 5800XTR2 Service Manual</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 5810 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-5810-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:48:17 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-5810-control-valve/</guid>

					<description><![CDATA[The Fleck 5810 control valve is apart of a series of commercial valves that are designed to provide unmatched strength, prevent occurrences of corrosion, last for long durations, and resistance to ultraviolet. The features of this valve, which includes a 3 or 5 cycle control that improves the productivity and dependability of the water treatment [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The Fleck 5810 control valve is apart of a series of commercial valves that are designed to provide unmatched strength, prevent occurrences of corrosion, last for long durations, and resistance to ultraviolet. The features of this valve, which includes a 3 or 5 cycle control that improves the productivity and dependability of the water treatment system.</p>
<h4 align="justify"><strong>Fleck 5810</strong></h4>
<p align="justify">The Fleck 5810 commercial valve produces a flow rate of around 36 GPM with backwash capabilities of 28 GPM. The backwashing process is geared towards water softener tanks and water filters of under 22&#8243; in diameter. Double backwash is also incorporated to ensure a decrease in hardness leakages. These valves are proven to work through a diagnostic tool which displays historical valve performance.</p>
<h5 align="justify"><strong>How to Order Fleck Valve?</strong></h5>
<ul>
<li>Inform us on the type of system that you are dealing with (water softeners or filters)</li>
<li>Clarify the precise flow rate required for your application</li>
<li>Specify the tank size that is being utilized to ensure the correct flow restrictor sizing</li>
<li>Fleck valve has a multitude of options so please discuss your application with Pure Aqua representative to offer the best options to fit your application.</li>
</ul>
<div align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Fiber Reinforced Polymer</td>
<td style="text-align: center; height: 18px; width: 170px;">3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</p></div>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Piston</strong></th>
<th style="text-align: center; width: 170px;"><strong>Downflow</strong></th>
<th style="text-align: center; width: 170px;"><strong>Upflow</strong></th>
<th style="text-align: center; width: 170px;"><strong>Filter</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Continuous<br />(15 psi drop)</td>
<td style="text-align: center; width: 170px;">36 GPM<br />8.2 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">35 GPM<br />7.9 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">31 GPM<br />7.0 m&sup3;/hr</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Peak<br />(25 psi drop)</td>
<td style="text-align: center; width: 170px;">47 GPM<br />10.6 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">45 GPM<br />10.1 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">40 GPM<br />9.0 m&sup3;/hr</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Cv<br />(flow at 1 psi drop)</td>
<td style="text-align: center; width: 170px;">9.4</td>
<td style="text-align: center; width: 170px;">8.9</td>
<td style="text-align: center; width: 170px;">8</td>
</tr>
<tr>
<td style="text-align: center; width: 170px;">Max. Backwash<br />(25 psi drop)</td>
<td style="text-align: center; width: 170px;">28 GPM<br />63 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">30 GPM<br />6.9 m&sup3;/hr</td>
<td style="text-align: center; width: 170px;">30 GPM<br />7.5 m&sup3;/hr</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Both</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">SXT: 0 &#8211; 199 minutes per cycle<br />XTR2: 0 &#8211; 240 min/cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 101px; width: 1170px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1166.19px;" colspan="3">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 342.557px; height: 10px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 10px; width: 821.648px;" colspan="2"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<th style="text-align: center; width: 342.557px; height: 10px;">1-1/4&#8243; Turbine:</th>
<th style="text-align: center; width: 421.648px; height: 10px;">SXT:</th>
<th style="text-align: center; width: 398.011px; height: 10px;">3XTR2:</th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; height: 26px; width: 342.557px;">2 &#8211; 40 GPM &plusmn; 5%<br />(0.45 &#8211; 49 m&sup3;/h)</td>
<td style="text-align: center; width: 421.648px; height: 26px;">1 &#8211; 999,900 gal<br />(0 &#8211; 3,785 m&sup3;)</td>
<td style="text-align: center; width: 398.011px; height: 26px;">1 &#8211; 9,999,999 gal<br />(0 &#8211; 378,541 m&sup3;)</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 63px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 10px;">
<th style="text-align: center; width: 1077.1px; height: 10px;" colspan="6">Dimensions</th>
</tr>
<tr style="height: 13px;">
<th style="text-align: center; width: 142.557px; height: 13px;"><strong>Distributor pilot</strong></th>
<th style="text-align: center; width: 141.648px; height: 13px;"><strong>Drain line</strong></th>
<th style="text-align: center; width: 201.648px; height: 13px;"><strong>Injector brine system</strong></th>
<th style="text-align: center; width: 163.466px; height: 13px;"><strong>Brine line</strong></th>
<th style="text-align: center; width: 224.375px; height: 13px;"><strong>Mounting base</strong></th>
<th style="text-align: center; width: 193.466px; height: 13px;"><strong>Height from top of tank</strong></th>
</tr>
<tr style="height: 10px;">
<td style="text-align: center; width: 142.557px; height: 10px;">1.05&#8243; O.D.</td>
<td style="text-align: center; width: 141.648px; height: 10px;">1/2&#8243; NPTF</td>
<td style="text-align: center; width: 201.648px; height: 10px;">1610 &#8211; 3/8&#8243;</td>
<td style="text-align: center; width: 163.466px; height: 10px;">3/8&#8243;</td>
<td style="text-align: center; width: 224.375px; height: 10px;">2.5&#8243; &#8211; 8 NPSM</td>
<td style="text-align: center; width: 193.466px; height: 10px;">11.3&#8243;</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<table class="tableCenter" style="height: 82px; width: 1182px;" width="1116" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 22px;">
<th style="text-align: center; width: 1178.01px; height: 22px;" colspan="4"><strong>Additional Information</strong></th>
</tr>
<tr style="height: 22px;">
<th style="text-align: center; width: 254.375px; height: 13px;"><strong>Electrical rating</strong></th>
<th style="text-align: center; width: 319.83px; height: 13px;"><strong>Estimated shipping weight</strong></th>
<th style="text-align: center; width: 330.739px; height: 13px;"><strong>Pressure</strong></th>
<th style="text-align: center; width: 267.102px; height: 13px;"><strong>Temperature</strong></th>
</tr>
<tr style="height: 40px;">
<td style="text-align: center; width: 254.375px; height: 10px;">12 Volts DC</td>
<td style="text-align: center; width: 319.83px; height: 10px;">11 lbs</td>
<td style="text-align: center; width: 330.739px; height: 10px;">Hydrostatic: 300 psi<br />Working: 20 &#8211; 125 psi</td>
<td style="text-align: center; width: 267.102px; height: 10px;">34 &#8211; 110&deg;F (1 &#8211; 43&deg;C)</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow-x: auto;">
<table class="tableCenter" style="height: 5px;" width="1103" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1098.92px;" colspan="5"><strong>Typical Applications</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 544px;"><strong>Water softener</strong></th>
<th style="text-align: center; width: 544px;"><strong>Filters</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 544px;">8 &#8211; 21&#8243; diameter</td>
<td style="text-align: center; width: 544px;">Filters 8 &#8211; 21&#8243; diameter</td>
</tr>
</tbody>
</table></div>
<div style="overflow-x: auto;">
<p>* As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards</p>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<ul>
<li>Fiber-reinforced polymer valve body for superior strength and durability, non-corrosive, and UV-resistant</li>
<li>Continuous service flow rate of 36 GPM with a backwash of 28 GPM</li>
<li>Backwash capability accommodates softener tanks up to 21&#8243; and filters up to 21&#8243; in diameter</li>
<li>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system</li>
<li>Time-tested, hydraulically-balanced piston for service and regeneration</li>
<li>Optical sensor for precision cycle positioning</li>
<li>Soft water refill for a cleaner brine tank</li>
<li>Designed with double backwash for reduced hardness leakage</li>
<li>Diagnostics for historical valve performance</li>
<li>Programming stored in memory and will not be lost due to power outages</li>
</ul>
<h5><strong>Options:</strong></h5>
<ul class="unIndentedList">
<li>Filter or softener control valves</li>
<li>Downflow co-current or upflow counter-current regeneration</li>
<li>Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</li>
<li>Fiber-reinforced polymer or stainless steel bypass valve</li>
<li>Variable reserve for increased efficiency</li>
<li>Programmable regeneration types for increased flexibility</li>
<li>Three color bezel options of black, silver, or blue</li>
<li><strong>XTR2</strong>&#8211; Premium touch screen LCD display with two programmable relay outputs for both normally opened and normally closed contacts</li>
<li><strong>SXT</strong>-Large LCD display with one programmable relay output for both normally open and normally closed contacts</li>
</ul>
<div></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
</div>
<ul>
<li>Commercial Softeners</li>
<li>Commercial Media Filters</li>
<li>Commercial Carbon Filters</li>
<li>Commercial Iron Removal Filters</li>
</ul>
</p></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 5810 Spec Sheet" href="../../../../content/pdf/fleck-5810-control-valve.pdf" target="_blank" rel="noopener">Fleck 5810 Spec Sheet</a> <br /><a title="Fleck 5800XTR2 Service Manual" href="https://www.pureaqua.com/content/pdf/fleck-5800xtr2-service-manual.pdf" target="_blank" rel="noopener">Fleck 5800XTR2 Service Manual</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck XRT2 Control Timer</title>
		<link>https://aquacomponents.sa/product/fleck-xrt2-control-timer/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:38 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-xrt2-control-timer/</guid>

					<description><![CDATA[Fleck brings you the Fleck XTR2 Controller &#8211; the first touchscreen control valve to hit&#160;the&#160;water industry. With its detailed screen descriptions, color LCD display, and familiar icons, the XTR2 controller brings ease of programming and a user-friendly experience to the table. Models System Type System Type 4 Valve Type 5800 5810 5812 Features Time of [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Fleck brings you the Fleck XTR2 Controller &#8211; the first touchscreen control valve to hit&nbsp;the&nbsp;water industry. With its detailed screen descriptions, color LCD display, and familiar icons, the XTR2 controller brings ease of programming and a user-friendly experience to the table.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p><strong>System Type</strong></p>
<ul>
<li>System Type 4</li>
</ul>
<h5><strong>Valve Type</strong></h5>
<ul>
<li>5800</li>
<li>5810</li>
<li>5812</li>
</ul>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Time of day super capacitor backup for power loss</li>
<li>Large color LCD touch screen display</li>
<li>Programmable relay output</li>
<li>Remote lockout and regen input</li>
<li>Easy electronic programming</li>
<li>Error alarm</li>
<li>Assistance screen with dealer contact information</li>
<li>Programmable assistance interval with alarm for service</li>
<li>Master settings by category</li>
<li>Intuitive nativation</li>
<li>Field Programmer for quick configuration and diagnostic data download to PC via USB</li>
<li>Password lockout screen for added security</li>
<li>Vacation mode to save water when not in use</li>
</ul>
<div>
<table class="tableCenter" style="height: 53px;" width="1065" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 40px;">
<th style="text-align: center; width: 720px; height: 10px;" colspan="3">Valve Specifications</th>
</tr>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 170px;"><strong>Valve material</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Inlet/Outlet</strong></th>
<th style="text-align: center; height: 18px; width: 170px;"><strong>Cycles</strong></th>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; height: 18px; width: 170px;">Fiber-reinforced polymer</td>
<td style="text-align: center; height: 18px; width: 170px;">0.75&#8243;, 1&#8243; or 1.25&#8243;</td>
<td style="text-align: center; height: 18px; width: 170px;">5</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</p></div>
<div>
<table class="tableCenter" style="height: 45px;" width="1068" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 680px;" colspan="4"><strong>Flow Rates (50 psi Inlet) &#8211; Valve Alone</strong></th>
</tr>
<tr>
<th style="text-align: center; width: 170px;"><strong>Continuous 15 psi drop</strong></th>
<th style="text-align: center; width: 170px;"><strong>Peak 25 psi drop</strong></th>
<th style="text-align: center; width: 170px;"><strong>Cv flow at 1 psi drop</strong></th>
<th style="text-align: center; width: 170px;"><strong>Max. Backwash 25 psi drop</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 170px;">21 GPM &bull; 4,8 m&sup3;/h</td>
<td style="text-align: center; width: 170px;">27 GPM &bull; 6,1 m&sup3;/h</td>
<td style="text-align: center; width: 170px;">5.4</td>
<td style="text-align: center; width: 170px;">(25 psi drop) 17 GPM &bull; 3,9 m&sup3;/h</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 83px;" width="1070" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center; width: 1066.19px;" colspan="3">Regeneration</th>
</tr>
<tr>
<th style="text-align: center; width: 353.466px;"><strong>Downflow/Upflow</strong></th>
<th style="text-align: center; width: 353.466px;"><strong>Adjustable cycles</strong></th>
<th style="text-align: center; width: 355.284px;"><strong>Time available</strong></th>
</tr>
<tr>
<td style="text-align: center; width: 353.466px;">Both</td>
<td style="text-align: center; width: 353.466px;">Yes</td>
<td style="text-align: center; width: 355.284px;">LXT: minutes calculated<br />SXT: 0-199 minutes per cycle<br />XTR2: 0-240 minutes per cycle</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div>
<table class="tableCenter" style="height: 154px; width: 1173px;" width="1081" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 18px;">
<th style="text-align: center; height: 18px; width: 1168.92px;" colspan="2">Meter Information</th>
</tr>
<tr style="height: 36px;">
<th style="text-align: center; width: 619.83px; height: 36px;" colspan="1"><strong>Meter accuracy</strong></th>
<th style="text-align: center; height: 36px; width: 547.102px;" colspan="1"><strong>Meter Capacity Range</strong></th>
</tr>
<tr style="height: 46px;">
<td style="text-align: center; height: 46px; width: 619.83px;">.25 &#8211; 15 GPM +/-5%</td>
<td style="text-align: center; width: 547.102px; height: 46px;">LXT: volume calculated<br />S XT: 1-999,900<br />XTR2: 1-99,999,999</td>
</tr>
</tbody>
</table></div>
<h5><strong>Accessories and Options</strong></h5>
<ul>
<li>Filter or softener control valves</li>
<li>Downflow co-current or upflow counter-current regeneration</li>
<li>Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</li>
<li>Fiber-reinforced polymer or stainless steel bypass valve</li>
<li>Variable reserve for increased efficiency</li>
<li>Programmable regeneration types for increased flexibility</li>
<li>Three color bezel options of black, silver, or blue</li>
<li><span>XTR2</span>&#8211; Premium touch screen LCD display with two programmable relay outputs for both normally opened and normally closed contacts</li>
<li><span>SXT</span>-Large LCD display and user-selectable time clock or metered function; usable for filtration and softener systems</li>
<li><span>LXT</span>&#8211; Midsize LCD display comes preprogrammed for your choices of softener or filter and time clock or metered, with a maximum of 5 parameters to complete set-up</li>
</ul>
<h5><strong>Certifications</strong></h5>
<ul>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 44 for Water Softener Performance.</li>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 372 for Lead Free Compliance.</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Outdoor applications<br />&nbsp;</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<div class="hl-custom-tab-content document"><font color="#0000FF"><a title="Fleck XRT2 Control Timer Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-xrt2-control-timer.pdf" target="_blank" rel="noopener"><font color="#0000FF">Fleck XRT2 Control Timer Data Sheet</font></a></font></div></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck XT Control Timer</title>
		<link>https://aquacomponents.sa/product/fleck-xt-control-timer/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:36 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-xt-control-timer/</guid>

					<description><![CDATA[Advanced Electronic Controller The XT advanced electronic controller is availablie for single control valve operation. The XT can be configured to the Fleck&#174; 2510, 2750, 2850, 2900, 3150, 3900, 9000, 9100 and 9500 valves. In Time Clock Delay mode, the XT will display the number of days until the next scheduled regeneration. Some meter delated [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Advanced Electronic Controller</p>
<p align="justify">The XT advanced electronic controller is availablie for single control valve operation. The XT can be configured to the Fleck&reg; 2510, 2750, 2850, 2900, 3150, 3900, 9000, 9100 and 9500 valves.</p>
<p align="justify">In Time Clock Delay mode, the XT will display the number of days until the next scheduled regeneration. Some meter delated types will display the volume remaining (SRV) minus the reserve. Once the volume remaining is zero, the display will start counting down the reserve volume and queue (RGQ) regeneration</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>SYSTEM TYPE</strong></h5>
<ul>
<li>System Type 4</li>
</ul>
<h5><strong>VALVE TYPE</strong></h5>
<ul>
<li>2510</li>
<li>2750</li>
<li>2850s</li>
<li>2850</li>
<li>2900s</li>
<li>3150</li>
<li>3900</li>
<li>7000</li>
<li>9000</li>
<li>9100</li>
<li>9500</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Time of day kept for up to 12 hours of power loss</li>
<li>Calculating Reserves:
<ul>
<li>Daily Variable &#8211; adjusts reserve based on previous day&#8217;s water usage</li>
<li>Day of Week &#8211; adjusts reserve for each day of the week based on an average of the last three weeks</li>
</ul>
</li>
<li>LED Status Indicator:
<ul>
<li>Blue: In Service</li>
<li>Green: In Regeneration</li>
<li>Red: Error with codes</li>
</ul>
</li>
<li>New shift key (left arrow) for digit selecing, allows faster programming</li>
<li>2 Line/16 character LCD backlit display</li>
<li>Defaults for all valve, piston, and cam types are stored</li>
<li>Diagnostics:
<ul>
<li>Current Flow Rate</li>
<li>Peak Flow Rate (can be reset)</li>
<li>Totalizer (can be reset)</li>
<li>Hours between Last two Regenerations</li>
<li>Hours between Last Regeneration</li>
<li>Volume Remaining (Adjustable)</li>
<li>Precious Days Usage</li>
<li>Reserve Volume</li>
<li>Software Version</li>
</ul>
</li>
<li>Uses same mounting hardware and cable harness as the 3200NXT and the 3214NXT</li>
<li>Easy installation with plug-in wiring harnesses</li>
<li>Programmable for Fleck&reg; or generic meters</li>
</ul>
<h5><strong>Accessories and Options</strong></h5>
<ul>
<li>Programmable auxiliary relay output
<ul>
<li>Dry contact Relay (fused at 3 amps)</li>
<li>Program entire Regeneration</li>
<li>Two programmable time windows during regeneration</li>
</ul>
</li>
<li>Remote Lock</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>For small commercial and industrial applications</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-documents">Docs</div>
</p>
<div class="hl-custom-tab-content document"><a title="Fleck XT Control Timer Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-xt-control-timer.pdf" target="_blank" rel="noopener"><font color="#0000FF">Fleck XT Control Timer Data Sheet</font></a></div></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck SXT Control Timer</title>
		<link>https://aquacomponents.sa/product/fleck-sxt-control-timer/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:35 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-sxt-control-timer/</guid>

					<description><![CDATA[Fleck SXT Controls provide easy, step-by-step programming at the touch of a button. The same SXT control drives&#160;6 different Fleck valves, saving you time in installation, service and training. Unlike other electronic valves, the SXT control&#160;performs without switching out cams or fumbling with jumpers, pins and cryptic calculations. A large backlit LCD display alternates between [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Fleck SXT Controls provide easy, step-by-step programming at the touch of a button.</p>
<p>The same SXT control drives&nbsp;6 different Fleck valves, saving you time in installation, service and training.</p>
<p>Unlike other electronic valves, the SXT control&nbsp;performs without switching out cams or fumbling with jumpers, pins and cryptic calculations.</p>
<p>A large backlit LCD display alternates between time of day, soft water remaining or days to regeneration, and tank in service (twin tank systems only). Fleck valves using an SXT control is the best entry-level solution for all your residential water treatment applications.</p>
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<ul>
<li>Filter or softener control valves</li>
<li>Downflow co-current or upflow counter-current regeneration</li>
<li>Brine cam auxiliary switch</li>
<li>Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</li>
<li>Fiber-reinforced polymer or stainless steel bypass valve</li>
<li>Programmable regeneration types for increased flexibility</li>
<li>Downflow double backwash cam for reduced hardness leakage</li>
<li>Swivel attachment for 360&deg; rotation of power head</li>
<li><strong>SXT &#8211;</strong> Large LCD display and userselectable time clock or metered function; usable for filtration and softener systems</li>
</ul>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul>
<li>Easy, user-friendly programming</li>
<li>Large, blue backlit LCD display</li>
<li>48 hour internal power backup capacitor</li>
<li>True time of day in hours and minutes</li>
<li>Volume of soft water remaining</li>
<li>Regeneration steps and cycle time remaining</li>
<li>Service and self diagnostic indicator</li>
<li>Quick and easy setup of capacity, regeneration time, and day override</li>
<li>Advanced programming options including up to 6 independently adjustable cycle times</li>
<li>Programming is stored in memory and will not be lost due to power outages</li>
<li>Electronic step-by-step regeneration</li>
<li>Regeneration tonight and regenerate now option</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Water softeners</li>
<li>Backwashing carbon and sediment filters</li>
<li>iron filters</li>
</ul>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck SXT Control Timer Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-sxt-control-timer.pdf" target="_blank" rel="noopener">Fleck SXT Control Timer Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck Manual Control</title>
		<link>https://aquacomponents.sa/product/fleck-manual-control/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:33 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-manual-control/</guid>

					<description><![CDATA[For applications where conditioned water is only required on an intermittent basis, such as cabins, RVs, or when AC power is not available. Allows you to manually control regeneration times and frequencies. Models Cycle Times and Flow Diagrams 1. In Service position. See page 7.2. Preliminary Rinse position.3. Backwash position.4. Brine Rinse position.5. Slow Rinse [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>For applications where conditioned water is only required on an intermittent basis, such as cabins, RVs, or when AC power is not available. Allows you to manually control regeneration times and frequencies.</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<p><strong>Cycle Times and Flow Diagrams</strong></p>
<p>1. In Service position. See page 7.<br />2. Preliminary Rinse position.<br />3. Backwash position.<br />4. Brine Rinse position.<br />5. Slow Rinse position.<br />6. Second Backwash position.<br />7. Settling Rinse position.<br />8. Brine Tank Refill position.</p>
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features and Benefits</strong></h5>
<ul>
<li>
<div class="first-sentence-half"><span class="nd-word"><span>Strong&nbsp;</span></span><span class="nd-word"><span>brass&nbsp;</span></span><span class="nd-word"><span>valve&nbsp;</span></span><span class="nd-word"><span>body&nbsp;</span></span><span class="nd-word"><span>without&nbsp;</span></span><span class="nd-word"><span>lead&nbsp;</span></span><span class="nd-word"><span>for&nbsp;</span></span><span class="nd-word"><span>exceptional&nbsp;</span></span><span class="nd-word"><span>performance&nbsp;</span></span><span class="nd-word"><span>and&nbsp;</span></span><span class="nd-word"><span>toughness</span></span></div>
</li>
<li>
<div class="second-sentence-half"><span class="nd-word"><span></span></span><span class="nd-word"><span>Capacity&nbsp;</span></span><span class="nd-word"><span>backwash&nbsp;</span></span><span class="nd-word"><span>treats&nbsp;</span></span><span class="nd-word"><span>tanks&nbsp;</span></span><span class="nd-word"><span>up&nbsp;</span></span><span class="nd-word"><span>to&nbsp;</span></span><span class="nd-word"><span>a&nbsp;</span></span><span class="nd-word"><span>diameter&nbsp;</span></span><span class="nd-word"><span>of&nbsp;</span></span><span class="nd-word"><span>30&nbsp;</span></span></div>
</li>
<li>
<div class="second-sentence-half"><span class="nd-word"><span></span></span><span class="nd-word"><span>1-1/2 </span></span><span class="nd-word"><span>upper&nbsp;</span></span><span class="nd-word"><span>mounting&nbsp;</span></span><span class="nd-word"><span>valve&nbsp;</span></span><span class="nd-word"><span>suitable&nbsp;</span></span><span class="nd-word"><span>for&nbsp;</span></span><span class="nd-word"><span>smaller&nbsp;</span></span><span class="nd-word"><span>industrial&nbsp;</span></span><span class="nd-word"><span>/&nbsp;</span></span><span class="nd-word"><span>commercial&nbsp;</span></span><span class="nd-word"><span>applications&nbsp;</span></span></div>
</li>
<li>
<div class="second-sentence-half"><span class="nd-word"><span></span></span><span class="nd-word"><span>Consistent </span></span><span class="nd-word"><span>brining&nbsp;</span></span><span class="nd-word"><span>with&nbsp;</span></span><span class="nd-word"><span>timed&nbsp;</span></span><span class="nd-word"><span>brine </span></span><span class="nd-word"><span>refills,&nbsp;</span></span><span class="nd-word"><span>regardless&nbsp;</span></span><span class="nd-word"><span>of&nbsp;</span></span><span class="nd-word"><span>the&nbsp;</span></span><span class="nd-word"><span>salt&nbsp;</span></span><span class="nd-word"><span>levels&nbsp; </span></span></div>
</li>
<li>
<div class="second-sentence-half"><span class="nd-word"><span></span></span><span class="nd-word"><span>7- </span></span><span class="nd-word"><span>or&nbsp;</span></span><span class="nd-word"><span>12-day&nbsp;</span></span><span class="nd-word"><span>clock&nbsp;</span></span><span class="nd-word"><span>choice,&nbsp;</span></span><span class="nd-word"><span>manual&nbsp;</span></span><span class="nd-word"><span>or&nbsp;</span></span><span class="nd-word"><span>meter&nbsp;</span></span><span class="nd-word"><span>option&nbsp; </span></span></div>
</li>
<li>
<div class="second-sentence-half"><span class="nd-word"><span></span></span><span class="nd-word"><span>Continuous&nbsp;</span></span><span class="nd-word"><span>51&nbsp;</span></span><span class="nd-word"><span>GPM&nbsp;</span></span><span class="nd-word"><span>flow&nbsp;</span></span><span class="nd-word"><span>rate,&nbsp;</span></span><span class="nd-word"><span>with&nbsp;</span></span><span class="nd-word"><span>49&nbsp;</span></span><span class="nd-word"><span>GPM&nbsp;</span></span><span class="nd-word"><span>backwash</span></span></div>
</li>
</ul>
<h5><strong>Accessories and Options</strong></h5>
<ul>
<li>Meter initiated regeneration</li>
<li>Backwash filter</li>
<li>No hard water bypass piston</li>
<li>Environmental cover</li>
<li>Electronic timer, ET or&nbsp;Systemax</li>
<li>Hot water (time clock&nbsp;180&deg;F; metered valve&nbsp;150&deg;F)</li>
<li>Manual operation</li>
<li>Service valve operator</li>
<li>Auxiliary switch</li>
<li>Side mount</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Water Softener</li>
<li>Iron, Sediment, Carbon, and Neutralizing Filters
<div class="tabtitle" id="custom-documents">Docs</div>
<p><span style="color: #0000ff;"><a title="Fleck Manual Control Valve Sheet" href="https://videos.pureaqua.us/pdf/40097_fleck_2510_manual.pdf" target="_blank" rel="noopener">Fleck Manual Control Valve Sheet</a></span></li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 3200 NXT Control Timer</title>
		<link>https://aquacomponents.sa/product/fleck-3200-nxt-control-timer/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:32 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-3200-nxt-control-timer/</guid>

					<description><![CDATA[The NXT Network Controller uses on-board communication capabilities to link multiple commercial valves (via off-the-shelf CAT3, CAT5, or better cables) for a variety of system types. Models &#160;System &#160;System Description &#160;Number of Tanks/Controls &#160;Type &#160;4 Single Unit &#160;1 Time Clock: No Meter&#160;Immediate: One MeterDelayed: One MeterRemote: No Meter &#160;5 Interlocked &#160;2, 3, or 4 Immediate: [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The NXT Network Controller uses on-board communication capabilities to link multiple commercial valves (via off-the-shelf CAT3, CAT5, or better cables) for a variety of system types.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;<strong>System</strong></span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><strong>&nbsp;System Description</strong></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><strong>&nbsp;Number of Tanks/Controls</strong></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><strong>&nbsp;Type</strong></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;4</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>Single Unit</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;1</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Time Clock: No Meter&nbsp;<br />Immediate: One Meter<br />Delayed: One Meter<br />Remote: No Meter</p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;5</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>Interlocked</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;2, 3, or 4</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Immediate: All Meters<br />Remote: No Meter</p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;6</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Series<br />Regeneration</p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;2, 3, or 4</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Immediate: One Meter<br />Delayed: One Meter<br />Remote: No Meter</p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;7</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Twin<br />Alternaiting</p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>2</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Immediate: One Meter<br />Remote: No Meter</p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;9</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Multiple Tank<br />Alternating</p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>2, 3, or 4</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p>Immediate: All Meters<br />Remote: No Meter</p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="156">
<p><span>&nbsp;14</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>Demand Recall</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<p><span>2, 3, or 4</span></p>
</td>
<td style="text-align: center;" valign="top" width="156">
<h5><span>Immediate: All Meters</span></h5>
</td>
</tr>
</tbody>
</table></div>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<p><strong>For Valves:</strong></p>
<ul>
<li>2750</li>
<li>2850S</li>
<li>2850</li>
<li>2900S</li>
<li>3150</li>
<li>3900</li>
<li>7000 (excludes system 14)</li>
</ul>
<h5><strong>Features and Benefits</strong></h5>
<ul>
<li>On-screen multilingual support: English, French, German, Portuguese, Spanish</li>
<li>Time of day super capacitor backup for power loss</li>
<li>2 line/ 16 character full text LCD backlit display</li>
<li>Left arrow button allows digit selecting in programming mode</li>
<li>Networks two to four valves via off-the-shelf CAT3, CAT5, or better cables</li>
<li>Field-configurable for all system types</li>
<li>LED Status indicator:
<ul>
<li>Blue: In Service</li>
<li>Flashing Blue: Regeneration Queued</li>
<li>Green: Regeneration</li>
<li>Flashing Green: Standby</li>
<li>Red: Error with codes</li>
</ul>
</li>
<li>Auxillary inputs and outputs:
<ul>
<li>Programmable relay output</li>
<li>Programmable chemical pump output</li>
<li>Remote lockout and regen input</li>
</ul>
</li>
<li>Easy Installation with plug-in wiring harnesses</li>
<li>Easy electronic programming</li>
<li>Diagnostics:
<ul>
<li>Current Flow Rate</li>
<li>Peak Flow Rate (can be reset)</li>
<li>Totalizer (can be reset)</li>
<li>Hours Between Last Two Regenerations</li>
<li>Hours Since Last Regeneration</li>
<li>Volume Remaining (adjustable)</li>
<li>Valve Address</li>
<li>Software Version</li>
</ul>
</li>
</ul>
<p></p>
<div class="tabtitle" id="custom-usage">Applications</div>
</p>
<h4><strong>Specifications</strong></h4>
<p><strong>REGENERATION TYPE</strong></p>
<ul>
<li>Meter Delayed Fixed Reserve</li>
<li>Meter Immediate</li>
<li>Remote Signal Start Immediate</li>
<li>Time Clock Delayed</li>
</ul>
<h5><strong>REGENERATION FLOW</strong></h5>
<ul>
<li>Downflow</li>
<li>Upflow Fill First</li>
<li>Upflow Brine First</li>
</ul>
<h5><strong>ELECTRICAL RATING</strong></h5>
<ul>
<li>24V Transformers:
<ul>
<li>115V AC +/- 20% input, 24V AC output</li>
<li>230V AC +/- 20% input, 24V AC output</li>
</ul>
</li>
</ul>
<p><strong>GENERIC METER GUIDELINES</strong></p>
<ul>
<li>Open collector output</li>
<li>Pulse rate generated must not exceed 100 pulses per second (100Hz) or 6,000 pulses per minute</li>
<li>Support for meter outputs in the range of 1-255 gallons (25.5m3) for every 1-255 pulses</li>
<li>Meter must operate at 5 VDC</li>
</ul>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 3200 NXT Control Timer Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-3200-nxt-control-timer.pdf" target="_blank" rel="noopener">Fleck 3200 NXT Control Timer Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck Electromechanical Timers</title>
		<link>https://aquacomponents.sa/product/fleck-electromechanical-timers/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:30 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-electromechanical-timers/</guid>

					<description><![CDATA[Fleck&#8217;s electromechanical timers are simple to program and easy to service. The robust electromechanical powerhead is designed with heavy-duty 3/8&#8243; wide plastic gears and a simple mechanical design for quick access to all internal components. Models TYPE CAPACITY 3/4&#8243; Standard 125-2,125 gal. (0.5-8 m&#179;) 3/4&#8243; Extended 325-10,625 gal. (2.5-40 m&#179;) 1&#8243; Standard 310-5,270 gal. (1.2-20 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span>Fleck&#8217;s electromechanical timers are simple to program and easy to service. The robust electromechanical powerhead is designed with heavy-duty 3/8&#8243; wide plastic gears and a simple mechanical design for quick access to all internal components.</span></p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<div style="overflow-x: auto;">
<table class="tableCenter tableLeft" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;" colspan="1">TYPE</th>
<th style="text-align: center;" colspan="1">CAPACITY</th>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>3/4&#8243; Standard</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>125-2,125 </span><span>gal. (0.5-8 m&sup3;)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>3/4&#8243; Extended</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>325-10,625 </span><span>gal. (2.5-40 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>1&#8243; Standard</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>310-5,270 </span><span>gal. (1.2-20 m&sup3;)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>1&#8243; Extended</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>1,550-26,350 </span><span>gal. (6-100 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>1&frac12;&#8221; Standard</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>625-10,625 </span><span>gal. (2.4-40 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>1&frac12;&#8221; Extended</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>3,125-53,125 </span><span>gal. (12-200 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>2&#8243; Standard</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>1,250-21,250 </span><span>gal. (5-75 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>2&#8243; Extended</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>6,250-106,250 </span><span>gal. (25-375 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>3&#8243; Standard</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>3,750-63,750 </span><span>gal. (14-240 m&sup3;</span><span>)</span></p>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="112">
<p><span>3&#8243; Extended</span></p>
</td>
<td style="text-align: center;" valign="top" width="176">
<p><span>18,750-318,750 </span><span>gal. (70-1200 m&sup3;</span><span>)</span></p>
</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<p><strong>Four different system configurations are available using either a time clock or meter to initiate a regeneration.</strong></p>
<ul>
<li>System Type 4 &#8211; Single Unit Operation</li>
<li>System Type 5 &#8211; Dual Unit, Individual Meter, Interlock Regeneration</li>
<li>System Type 6 &#8211; Dual Unit, Single Remote Meter, Series Regeneration</li>
<li>System Type 7 &#8211; Dual Unit, Single Remote Meter, Alternating Regeneration</li>
<li>Regeneration Types &#8211; Time Clock Delayed, Meter Delayed, Meter Immediate</li>
</ul>
<h5><strong>Valve Type</strong></h5>
<ul>
<li>2510</li>
<li>2750</li>
<li>2850</li>
<li>2850s</li>
<li>2900s</li>
<li>3150</li>
<li>3900</li>
<li>9000</li>
<li>9100</li>
<li>9500</li>
</ul>
<h5><strong>Skipper Wheels</strong></h5>
<ul>
<li>7 Day: Regenerate selected&nbsp;day(s) of the week</li>
<li>12 Day:Regenerate increments&nbsp;of 1, 2, 3, 4, 6, &amp; 12 days</li>
</ul>
<h5><strong>Electrical Rating</strong></h5>
<ul>
<li>24, 100, 120, 240, VAC, 50/60 Hz</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Suitable for indoor or outdoor applications.</li>
</ul>
<p><div class="tabtitle" id="custom-documents">Docs</div>
</p>
<p class=" hl-custom-tab-content document"><a title="Fleck Electromechanical Timers Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-electromechanical-timers.pdf" target="_blank" rel="noopener">Fleck Electromechanical Timers Data Sheet</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fleck 5000 Control Valve</title>
		<link>https://aquacomponents.sa/product/fleck-5000-control-valve/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:46:29 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/fleck-5000-control-valve/</guid>

					<description><![CDATA[Programming ease with options for filter and softener applications.&#160;Fiber-reinforced polymer valve body for superior strength and durability, non-corrosive, and UV-resistant Models Accessories and Options Filter or softener control valves Downflow co-current or upflow counter-current regeneration Brine cam auxiliary switch Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat Fiber-reinforced polymer or stainless steel bypass [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">Programming ease with options for filter and softener applications.&nbsp;Fiber-reinforced polymer valve body for superior strength and durability, non-corrosive, and UV-resistant</p>
<p align="justify">
<div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>Accessories and Options</strong></h5>
<ul>
<li>Filter or softener control valves</li>
<li>Downflow co-current or upflow counter-current regeneration</li>
<li>Brine cam auxiliary switch</li>
<li>Plumbing connections in 3/4&#8243; to 1-1/4&#8243; NPT, BSP, and sweat</li>
<li>Fiber-reinforced polymer or stainless steel bypass valve</li>
<li><span>SXT</span>&#8211; Large LCD display and user-selectable time clock or metered function; usable for filtration and softener systems</li>
<li style="list-style-type: none;">&nbsp;</li>
</ul>
<p align="justify">
<p align="justify">
<div class="tabtitle" id="custom-features">Features</div>
</p>
<h5><strong>Features and Benefits</strong></h5>
<ul>
<li>Fiber-reinforced polymer valve body for superior strength and durability, non-corrosive, and UV-resistant</li>
<li>Continuous service flow rate of 21 GPM with a backwash of 17 GPM</li>
<li>Backwash capability accommodates softener tanks up to 16&#8243; and filter up to 16&#8243; in diameter</li>
<li>Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system</li>
<li>Super capacitor for keeping time of day during power outage</li>
<li>Time-tested, hydraulically-balanced piston for service and regeneration</li>
<li>Soft water refill for a cleaner brine tank &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>
<li>Diagnostics for historical valve performance</li>
<li>Programming stored in memory and will not be lost due to power outages</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<h5><strong>Certifications</strong></h5>
<ul>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 44 for Water Softener Performance</li>
<li>Tested and Certified by the WQA to NSF/ANSI Standard 372 for Lead Free Compliance</li>
</ul>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="Fleck 5000 Control Valve Data Sheet" href="https://www.pureaqua.com/content/pdf/fleck-5000-control-valve.pdf" target="_blank" rel="noopener">Fleck 5000 Control Valve Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
