<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DUPONT Filmtec Membranes &#8211; Aqua Components</title>
	<atom:link href="https://aquacomponents.sa/product-category/dupont-filmtec-membranes/feed/" rel="self" type="application/rss+xml" />
	<link>https://aquacomponents.sa</link>
	<description>Reliable Water Solutions for Saudi Arabia</description>
	<lastBuildDate>Thu, 13 Mar 2025 12:54:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  
<!-- This file should primarily consist of HTML with a little bit of PHP. -->
<div class="wc_public_wrapper wc_tool_text">
			<p id="wc_tooltip"><a href="https://api.whatsapp.com/send?phone=+966574945415&#038;text=Welcome%20to%20Aqua%20Components%20LLC.%20Please%20send%20your%20inquiry%20to%20sales@aquacomponents.sa" class="wc_icon_display wc_medium wc_bottom_left" tooltip="Aqua Components support" target="_blank" style="background-color:#189d0e;border-color:#ffffff;display:inline-block !important;"><i class="fa fa-whatsapp" aria-hidden="true"></i></a>
		<input type="hidden" id="wc_main_hvr_color" value="#000000">
			<input type="hidden" id="wc_main_bdr_color" value="#ffffff">
		</p>
		</div>  	<item>
		<title>DUPONT  FILMTEC BW30-PRO-400/34 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-bw30-pro-400-34-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:33 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-bw30-pro-400-34-membrane/</guid>

					<description><![CDATA[DUPONT FILMTEC BW30-400/34 Elements are ideal for reverse osmosis plant managers and operators dealing with challenging waters and wastewaters and looking for consistent, high performance, long element life and increased productivity. Models Specifications Product Active Area Feed Spacer Thickness Permeate Flow Rate Typical Stabilized Salt Rejection Minimum Salt Rejection DUPONT FILMTEC Element (ft2) (m2) Thickness [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">DUPONT FILMTEC BW30-400/34 Elements are ideal for reverse osmosis plant managers and operators dealing with challenging waters and wastewaters and looking for consistent, high performance, long element life and increased productivity.</p>
<p><div class="tabtitle" id="custom-specifications">Models</div>
</p>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="table-center" style="width: 1076px; height: 93px;" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 36px;">
<td style="text-align: center; width: 145.284px; height: 36px;"><strong>Product</strong></td>
<td style="text-align: center; width: 146.193px; height: 36px;" colspan="2"><strong>Active Area</strong><br /><strong><br /></strong></td>
<td style="text-align: center; width: 144.375px; height: 36px;"><strong>Feed Spacer Thickness</strong></td>
<td style="text-align: center; width: 130.739px; height: 36px;" colspan="2"><strong>Permeate Flow Rate</strong><br /><strong><br /></strong></td>
<td style="text-align: center; width: 207.102px; height: 36px;"><strong>Typical Stabilized Salt Rejection</strong></td>
<td style="text-align: center; width: 157.102px; height: 36px;"><strong>Minimum Salt Rejection</strong></td>
</tr>
<tr style="height: 39px;">
<td style="text-align: center; width: 145.284px; height: 39px;"><strong>DUPONT FILMTEC Element</strong></td>
<td style="text-align: center; width: 73.4659px; height: 39px;">(ft<sup>2</sup>)</td>
<td style="text-align: center; width: 70.7386px; height: 39px;">(m<sup>2</sup>)</td>
<td style="text-align: center; width: 144.375px; height: 39px;"><span>Thickness (mil)</span></td>
<td style="text-align: center; width: 130.739px; height: 39px;">&nbsp;(GPD)</td>
<td style="text-align: center; width: 128.92px;">(m<sup>3</sup>/day)</td>
<td style="text-align: center; width: 207.102px; height: 39px;">&nbsp;(%)</td>
<td style="text-align: center; width: 157.102px; height: 39px;">&nbsp;(%)</td>
</tr>
<tr style="height: 18px;">
<td style="text-align: center; width: 145.284px; height: 18px;"><strong>BW30-400/34</strong></td>
<td style="text-align: center; width: 73.4659px; height: 18px;">400</td>
<td style="text-align: center; width: 70.7386px; height: 18px;">37</td>
<td style="text-align: center; width: 144.375px; height: 18px;">34</td>
<td style="text-align: center; width: 130.739px; height: 18px;">10.500</td>
<td style="text-align: center; width: 128.92px;">40</td>
<td style="text-align: center; width: 207.102px; height: 18px;">&nbsp;99.5</td>
<td style="text-align: center; width: 157.102px; height: 18px;">&nbsp;99.0</td>
</tr>
</tbody>
</table></div>
</p>
<p><div class="tabtitle" id="custom-features">Features</div>
</p>
<ul class="cl-product-description__items">
<li>&nbsp;Proven performance</li>
<li>&nbsp;Delivers high quality permeate water while minimizing CAPEX</li>
<li>&nbsp;Offers the most effective cleaning performance, robustness and durability due to its widest cleaning pH range (1 &ndash; 13) tolerance and the support of DUPONT technical representatives</li>
</ul>
<p><div class="tabtitle" id="custom-usage">Applications</div>
</p>
<ul>
<li>Industrial water demineralization</li>
<li>Production of municipal drinking water</li>
<li>Water reuse</li>
</ul>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title=" DUPONT FILMTEC BW30-400/34 membrane " href="https://www.pureaqua.com/content/pdf/dupont-dow-filmtec-bw30-400-34-membrane-pro.pdf" target="_blank" rel="noopener">DUPONT FILMTEC BW30 400/34 membrane Data Sheet</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC SW30HRLE-400 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-sw30hrle-400-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:29 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-sw30hrle-400-membrane/</guid>

					<description><![CDATA[The DUPONT FILMTEC SW30HRLE-400 delivers high performance over the operating lifetime without the use of oxidative post-treatments and provides high NaCl and boron rejection to help meet World Health Organization (WHO) and other drinking water standards. DUPONT FILMTEC SW30HRLE-400 comes with the unique iLEC&#8482; Interlocking Endcaps that reduce system operating costs and reduce the risk [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The DUPONT FILMTEC SW30HRLE-400 delivers high performance over the operating lifetime without the use of oxidative post-treatments and provides high NaCl and boron rejection to help meet World Health Organization (WHO) and other drinking water standards. DUPONT FILMTEC SW30HRLE-400 comes with the unique iLEC&trade; Interlocking Endcaps that reduce system operating costs and reduce the risk of o-ring leaks that cause poor water quality.</p>
<p align="justify">DUPONT FILMTEC SW30HRLE-400 offers high rejection and low total cost of water for seawater desalination.</p>
<h4><strong>Advantages</strong></h4>
<ul>
<li>High flux reduces energy use or pressure required</li>
<li>Good rejection results in good quality water</li>
<li>High boron rejection</li>
<li>Filmtec performance and quality</li>
</ul>
<h4><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<p><strong>General Information</strong></p>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. Refer to DUPONT&trade; FILMTEC&trade; Reverse Osmosis and Nanofiltration Element Three-Year Prorated Limited Warranty (Form No. 609-35010)</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center;" rowspan="2"><strong>Product</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Part number</strong></td>
<td style="text-align: center;" colspan="2"><strong>Active area</strong></td>
<td style="text-align: center;" colspan="2"><strong>Maximum operating pressure</strong></td>
<td style="text-align: center;" colspan="2"><strong>Permeate flow rate</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Stabilized boron rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Minimum salt rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Stabilized saltrejection %</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>ft<sup>2</sup></strong></td>
<td style="text-align: center;"><strong>(m<sup>2</sup>)</strong></td>
<td style="text-align: center;"><strong>psig</strong></td>
<td style="text-align: center;"><strong>(bar)</strong></td>
<td style="text-align: center;"><strong>GPD</strong></td>
<td style="text-align: center;"><strong>(m<sup>3</sup>/d)</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>SW30HR LE-400i</strong></td>
<td style="text-align: center;">246512</td>
<td style="text-align: center;">400</td>
<td style="text-align: center;">(37)</td>
<td style="text-align: center;">1,200</td>
<td style="text-align: center;">(83)</td>
<td style="text-align: center;">7,500</td>
<td style="text-align: center;">(28)</td>
<td style="text-align: center;">92</td>
<td style="text-align: center;">99.65</td>
<td style="text-align: center;">99.8</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">DUPONT Water Process Solutions offers various premium seawater reverse osmosis (RO) elements designed to reduce capital and operation cost of seawater RO systems. DUPONT&trade; FILMTEC&trade; elements combine premium membrane performance with automated precision fabrication and maximize system output to provide unprecedented performance. The DUPONT&trade; FILMTEC&trade; SW30HR LE-400i element offers a combination of high rejection and low energy requirements to allow lower total costs with medium and high salinity feedwater. DUPONT FILMTEC SW30HR LE-400i element comes with the distinct iLEC&trade; Interlocking Endcaps that help reduce system operating costs and reduce the risk of o-ring leaks that cause poor water quality. See Form No. 609-00446 for information on the cost-saving benefits of iLEC Interlocking Endcaps. Benefits of the DUPONT FILMTEC SW30HR LE-400i element include:</p>
<ul>
<li>Enables systems to be designed and operated to optimize operating cost through lower energy consumption or to optimize capital cost through higher productivity at lower operating fluxes.</li>
<li>High NaCl and boron rejection to help meet World Health Organization (WHO) and other drinking water standards.</li>
<li>Effective use in permeate staged seawater desalination systems without impairing the performance of the DUPONTnstream stage.</li>
<li>High performance over the operating lifetime without the use of oxidative post-treatments. This is one reason DUPONT FILMTEC elements are more durable and may be cleaned more effectively over a wider pH range (1-13) than other RO elements.</li>
<li>Automated, precision fabrication with a greater number of shorter membrane leaves reducing the effect of overall fouling and maximizing element efficiency, helping to lower your cost of operation.</li>
</ul>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperaturea 113&deg;F (45&deg;C)</li>
<li>Maximum Element Pressure Drop 15 psig (1.0 bar)</li>
<li>pH Range, Continuous Operation 2 &#8211; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 13</li>
<li>Maximum Feed Silt Density Index (SDI) SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater desalination</li>
<li>Municipal drinking water</li>
<li>Industrial desalination</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document" align="justify"><a title="DUPONT FILMTEC SW30HRLE-400 Membrane" href="https://www.pureaqua.com/content/pdf/dupont-dow-filmtec-SW30-HRLE-400-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC SW30HRLE-400 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC SW30HRLE-370/34 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-sw30hrle-370-34-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:26 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-sw30hrle-370-34-membrane/</guid>

					<description><![CDATA[DUPONT FILMTEC&#8482; SW30HRLE-370/34 element is a durable, high-rejection, high-productivity seawater element for use in high fouling or challenging feedwater conditions, helping to support smooth operations and low cost of water. Advantages High flux reduces energy use or pressure required Good rejection results in good quality water High boron rejection Filmtec performance and quality Important Information [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>DUPONT FILMTEC&trade; SW30HRLE-370/34 element is a durable, high-rejection, high-productivity seawater element for use in high fouling or challenging feedwater conditions, helping to support smooth operations and low cost of water.</p>
<h4><strong>Advantages</strong></h4>
<ul>
<li>High flux reduces energy use or pressure required</li>
<li>Good rejection results in good quality water</li>
<li>High boron rejection</li>
<li>Filmtec performance and quality</li>
</ul>
<h4><strong>Important Information</strong></h4>
<p>Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p>Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p>Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4><strong>Operation Guidelines</strong></h4>
<p>Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. Refer to DUPONT&trade; FILMTEC&trade; Reverse Osmosis and Nanofiltration Element Three-Year Prorated Limited Warranty (Form No. 609-35010)</li>
<li>To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center;" rowspan="2"><strong>Product</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Part Number</strong></td>
<td style="text-align: center;" colspan="2"><strong>Active Area</strong></td>
<td style="text-align: center;" colspan="2"><strong>Maximum Operating Pressure</strong></td>
<td style="text-align: center;" colspan="2"><strong>Permeate Flow Rate</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Stabilized Boron Rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Minimum Salt Rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Stabilized Salt Rejection %</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>ft<sup>2</sup></strong></td>
<td style="text-align: center;"><strong>(m<sup>2</sup>)</strong></td>
<td style="text-align: center;"><strong>psig</strong></td>
<td style="text-align: center;"><strong>(bar)</strong></td>
<td style="text-align: center;"><strong>GPD</strong></td>
<td style="text-align: center;"><strong>(m<sup>3</sup>/d)</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>SW30HRLE-370/34</strong></td>
<td style="text-align: center;">297</td>
<td style="text-align: center;">370</td>
<td style="text-align: center;">(34.4)</td>
<td style="text-align: center;">1,200</td>
<td style="text-align: center;">(83)</td>
<td style="text-align: center;">6,700</td>
<td style="text-align: center;">(25)</td>
<td style="text-align: center;">99.65</td>
<td style="text-align: center;">99.8</td>
<td style="text-align: center;">99.7</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p>DUPONT Water &amp; Process Solutions offers various premium seawater reverse osmosis (RO) elements designed to produce high quality water and reduce capital and operation cost of seawater RO systems. These products combine premium membrane performance with automated precision fabrication to provide reliable and consistent performance.<br />DUPONT FILMTEC&trade; SW30HRLE-370/34 element is a durable, high-rejection, high-productivity seawater element for use in high fouling or challenging feedwater conditions, helping to support smooth operations and low cost of water.</p>
<h5><strong>The benefits of DUPONT FILMTEC&trade; SW30HRLE-370/34 elements include:</strong></h5>
<ul>
<li>A wide 34 mil feed spacer to lessen the impact of fouling on pressure drop across a vessel and enhance cleaning effectiveness.</li>
<li>An active area of 370 square feet maximizing productivity and enabling accurate and predictable system design and operating flux.</li>
<li>Utilization of the distinct iLEC&trade; interlocking endcaps that help to reduce system operating costs and reduce the risk of o-ring leaks that cause poor water quality.</li>
<li>Effective use in permeate staged seawater desalination systems without impairing the performance of the downstream stage.</li>
<li>High performance over the operating lifetime without the use of oxidative post-treatments. DUPONT FILMTEC elements are more durable and may be cleaned over a wider pH range (1-13).</li>
<li>Automated, precision fabrication with a greater number of shorter membrane leaves reducing the effect of overall fouling and maximizing element efficiency.</li>
</ul>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Element Pressure Drop 13 psig (0.9 bar)</li>
<li>pH Range, Continuous Operation 2 &ndash; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &ndash; 13</li>
<li>Maximum Feed Silt Density Index (SDI) SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater desalination</li>
<li>Municipal drinking water</li>
<li>Industrial desalination</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT Filmtec SW30HRLE-370/34 Membrane" href="https://www.pureaqua.com/content/pdf/dow-filmtec-sw30hrle-370-34i-membrane.pdf" target="_blank" rel="noopener">DUPONT Filmtec SW30HRLE-370/34 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC SW30XHR-440 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-sw30xhr-440-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:23 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-sw30xhr-440-membrane/</guid>

					<description><![CDATA[The DUPONT FILMTEC SW30XHR-PRO-440 element is the highest rejection seawater RO element in the DUPONT FILMTEC element portfolio, enabling stringent water quality requirements to be met reliably with single pass seawater systems in most situations. In addition, the combination of high active area and thick feed spacer results in higher productivity and lower cleaning frequency, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The DUPONT FILMTEC SW30XHR-PRO-440 element is the highest rejection seawater RO element in the DUPONT FILMTEC element portfolio, enabling stringent water quality requirements to be met reliably with single pass seawater systems in most situations. In addition, the combination of high active area and thick feed spacer results in higher productivity and lower cleaning frequency, which enable sustainable lower lifecycle cost.</p>
<h4><strong>Advantages</strong></h4>
<ul>
<li>High flux reduces energy use or pressure required</li>
<li>Good rejection results in good quality water</li>
<li>High boron rejection</li>
<li>Filmtec performance and quality</li>
</ul>
<h4><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4 align="justify"><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
<li>Please refer to the product technical manual.</li>
</ul>
<h4><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. Refer to FILMTEC&trade; Reverse Osmosis and Nanofiltration Element Three-Year Prorated Limited Warranty (Form No. 609-35010).</li>
<li>To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
<li>Wear protective eye shields, gloves, and sleeves to avoid prolonged contact with eyes, skin, and clothing.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center; width: 108.011px;"><strong>Product</strong></td>
<td style="text-align: center; width: 81.6477px;"><strong>Part Number</strong></td>
<td style="text-align: center; width: 151.648px;"><strong>Active Area ft<sup>2</sup> (m<sup>2</sup>)</strong></td>
<td style="text-align: center; width: 280.739px;"><strong>Maximum Operating Pressure psig (bar)</strong></td>
<td style="text-align: center; width: 227.102px;"><strong>Permeate Flow Rate gpd (m<sup>3</sup>/d)</strong></td>
<td style="text-align: center; width: 205.284px;"><strong>Stabilized Boron Rejection %</strong></td>
<td style="text-align: center; width: 188.011px;"><strong>Minimum Salt Rejection %</strong></td>
<td style="text-align: center; width: 193.466px;"><strong>Stabilized Salt Rejection %</strong></td>
</tr>
<tr>
<td style="text-align: center; width: 108.011px;"><strong>SW30XHR-PRO-440</strong></td>
<td style="text-align: center; width: 81.6477px;">337649</td>
<td style="text-align: center; width: 151.648px;">440 (41)</td>
<td style="text-align: center; width: 280.739px;">1,200 (83)</td>
<td style="text-align: center; width: 227.102px;">6,600 (25.0)</td>
<td style="text-align: center; width: 205.284px;">93</td>
<td style="text-align: center; width: 188.011px;">99.7</td>
<td style="text-align: center; width: 193.466px;">99.82</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">Dow Water &amp; Process Solutions offers various premium seawater reverse osmosis (RO) elements designed to produce high quality water which may reduce capital and operation costs of desalination systems. FILMTEC&trade; products combine excellent membrane quality with automated precision fabrication to take system performance to unprecedented levels.</p>
<p align="justify">The DUPONT&trade; FILMTEC&trade; SW30XHR-PRO-440 element is the highest rejection seawater RO element in the DUPONT FILMTEC element portfolio, enabling stringent water quality requirements to be met reliably with single pass seawater systems in most situations. In addition, the combination of highest active area and thickest feed spacer results in higher productivity and lower cleaning frequency which enable sustainable lower lifecycle cost. Benefits of the FILMTEC SW30XHR-PRO-440 element include:</p>
<ul>
<li>Highest NaCl and boron rejection to help meet World Health Organization (WHO) and other drinking water standards more cost effectively.</li>
<li>The highest guaranteed active area of 440 ft2 (41 m<sup>2</sup>) permits lowest system cost by maximizing productivity and enables accurate and predictable system design and operating flux.</li>
<li>The combination of highest active area with thickest feed spacer (28 mil) allows low cleaning frequency and high cleaning efficiency.</li>
<li>Utilization of the distinct iLEC&trade; interlocking endcaps helps reduce system operating costs and reduce the risk of o-ring leaks that can cause poor water quality (See Form No. 609-00446 for information on cost-saving benefits).</li>
<li>Sustainable high performance over the operating lifetime, because oxidative treatments are not used in membrane production. This is one reason DUPONT FILMTEC elements are more durable and may be cleaned more effectively over a wider pH range (1-13) than most other RO elements, which use oxidative treatments.</li>
<li>Effective use in permeate staged seawater desalination systems without impairing the performance of the downstream stage.</li>
</ul>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Element Pressure Drop 13 psig (0.9 bar)</li>
<li>pH Range, Continuous Operation 2 &ndash; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &ndash; 13</li>
<li>Maximum Feed Silt Density Index (SDI) SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater desalination</li>
<li>Municipal drinking water</li>
<li>Industrial desalination</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC SW30XHR-PRO-440 Membrane" href="https://www.pureaqua.com/content/pdf/dow-filmtec-SW30XHR-PRO-440-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC SW30XHR-PRO-440 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC SW30XLE-400 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-sw30xle-400-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:19 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-sw30xle-400-membrane/</guid>

					<description><![CDATA[DUPONT FILMTEC&#160;SW30XLE-400 offers a good combination of productivity and rejection resulting in a low energy seawater element and low operating cost. It is ideal for two-pass seawater designs and high TDS brackish water applications. DUPONT FILMTEC SW30XLE-400 comes with iLEC&#8482; Interlocking Endcaps that reduce system operating costs and reduce the risk of o-ring leaks that [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">DUPONT FILMTEC&nbsp;SW30XLE-400 offers a good combination of productivity and rejection resulting in a low energy seawater element and low operating cost. It is ideal for two-pass seawater designs and high TDS brackish water applications. DUPONT FILMTEC SW30XLE-400 comes with iLEC&trade; Interlocking Endcaps that reduce system operating costs and reduce the risk of o-ring leaks that cause poor water quality.</p>
<h4><strong>Advantages</strong></h4>
<ul>
<li>High flux reduces energy use or pressure required</li>
<li>Good rejection results in good quality water</li>
<li>High boron rejection</li>
<li>Filmtec performance and quality</li>
</ul>
<h4><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="text-align: center;" rowspan="2"><strong>Product</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Part number</strong></td>
<td style="text-align: center;" colspan="2"><strong>Active area</strong></td>
<td style="text-align: center;" colspan="2"><strong>Maximum operating pressure&nbsp;</strong></td>
<td style="text-align: center;" colspan="2"><strong>Permeate flow rate</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Typical boron rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Minimum salt rejection %</strong></td>
<td style="text-align: center;" rowspan="2"><strong>Stabilized saltrejection %</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>ft<sup>2</sup></strong></td>
<td style="text-align: center;"><strong>(m<sup>2</sup>)</strong></td>
<td style="text-align: center;"><strong>psig</strong></td>
<td style="text-align: center;"><strong>(bar)</strong></td>
<td style="text-align: center;"><strong>GPD</strong></td>
<td style="text-align: center;"><strong>(m<sup>3</sup>/d)</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>SW30XLE-400</strong></td>
<td style="text-align: center;">219219</td>
<td style="text-align: center;">400</td>
<td style="text-align: center;">(37)</td>
<td style="text-align: center;">1,200</td>
<td style="text-align: center;">(83)</td>
<td style="text-align: center;">9,000</td>
<td style="text-align: center;">(34)</td>
<td style="text-align: center;">91.5</td>
<td style="text-align: center;">99.6</td>
<td style="text-align: center;">99.8</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">DUPONT Water &amp; Process Solutions offers various premium seawater reverse osmosis (RO) elements to reduce capital and operation cost of seawater RO systems. DUPONT FILMTEC&trade; products combine premium membrane performance with automated precision fabrication and maximize system output to unprecedented performance.</p>
<p align="justify">DUPONT FILMTEC&trade; SW30XLE-400 offers an unequalled combination of productivity and rejection. This is the lowest energy seawater element available on the market, enabling lowest operation cost. It is also ideal for two-pass seawater designs and high TDS brackish water applications. DUPONT FILMTEC SW30XLE-400 comes with the unique iLEC&trade; Interlocking Endcaps that reduce system operating costs and reduce the risk of o-ring leaks that cause poor water quality. See Form No. 609-00446 for information on the trouble-free cost-saving benefits of iLEC Interlocking Endcaps. Benefits of SW30XLE-400 include:</p>
<ul>
<li>Highest productivity available, with active area of 400 sq. ft., enables systems to be designed to deliver the lowest total cost of water by optimizing energy consumption, system productivity and operating flux.</li>
<li>Can effectively be used in permeate staged seawater desalination systems without impairing the performance of the DUPONTnstream stage.</li>
<li>Delivers high performance over the operating lifetime without the use of oxidative post-treatments like many competitive products. This is one reason DUPONT FILMTEC elements are more durable and may be cleaned more effectively over a wider pH range (1-13) than other RO elements.</li>
<li>Automated, precision fabrication with a greater number of shorter membrane leaves reduces the effect of overall fouling and maximizes element efficiency, lowering your cost of operation.</li>
</ul>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperaturea 113&deg;F (45&deg;C)</li>
<li>Maximum Element Pressure Drop 15 psig (1.0 bar)</li>
<li>pH Range, Continuous Operation 2 &#8211; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 13</li>
<li>Maximum Feed Silt Density Index (SDI) SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Seawater desalination</li>
<li>Municipal drinking water</li>
<li>Industrial desalination</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC SW30XLE-400 Membrane" href="https://www.pureaqua.com/content/pdf/dupont-dow-filmtec-SW30-XLE-400-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC SW30XLE-400 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC BW30FR-365 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-bw30fr-365-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:16 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-bw30fr-365-membrane/</guid>

					<description><![CDATA[DUPONT&#8482; FILMTEC&#8482; BW30FR-365 elements have purified high biofouling feed waters since 1997. Numerous customers around the world have experienced lower operating costs by using DUPONT FILMTEC fouling resistant elements due to their exceptional fouling resistance and cleanability. Important Information Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">DUPONT&trade; FILMTEC&trade; BW30FR-365 elements have purified high biofouling feed waters since 1997. Numerous customers around the world have experienced lower operating costs by using DUPONT FILMTEC fouling resistant elements due to their exceptional fouling resistance and cleanability.</p>
<h4><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the DUPONT&trade; FILMTEC&trade; Reverse Osmosis and Nanofiltration Three-Year Prorated Limited Warranty (Form No. 609-35010) will be null and void.</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;"><strong>Product</strong></th>
<th style="text-align: center;"><strong>Part number</strong></th>
<th style="text-align: center;"><strong>Active area ft<sup>2</sup> (m<sup>2</sup>)</strong></th>
<th style="text-align: center;"><strong>Feed spacer thickness (mil)</strong></th>
<th style="text-align: center;"><strong>Permeate flow rate gpd (m<sup>3</sup>/d)</strong></th>
<th style="text-align: center;"><strong>Stabilized salt rejection (%)</strong></th>
<th style="text-align: center;">Minimum salt rejection (%)</th>
</tr>
<tr>
<th style="text-align: center;"><strong>BW30FR-365</strong></th>
<td style="text-align: center;">174961</td>
<td style="text-align: center;">365 (34)</td>
<td style="text-align: center;">34</td>
<td style="text-align: center;">9,500 (36)</td>
<td style="text-align: center;">99.5</td>
<td style="text-align: center;">99</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">DUPONT&trade; FILMTEC&trade; BW30FR-365 elements have purified high biofouling feed waters since 1997. Numerous customers around the world have experienced lower operating costs by using DUPONT FILMTEC fouling resistant elements due to their exceptional fouling resistance and cleanability. The BW30FR-365 element features:</p>
<ul>
<li>A wide (34 mil) feed spacer to facilitate improved cleaning.</li>
<li>A proprietary modification to the FT30 membrane chemistry providing superior cleanability and resistance to fouling.</li>
<li>DUPONT FILMTEC membrane with one of the widest pH cleaning ranges in the industry (pH 1-13) allowing for effective cleaning of scaling, organic compounds and biofilm.</li>
<li>Efficient membrane element design with more, shorter membrane leaves to help reduce the overall effect of fouling.</li>
</ul>
<p align="justify">The DUPONT FILMTEC BW30FR-365 element can be used for both potable and non-potable water applications.<br />A system designer can take advantage of this high productivity, high rejection, fouling resistant reverse osmosis (RO) element in any system design where the potential of high biofouling is expected. In addition, existing installations that are experiencing high biofouling or frequent cleanings can be upgraded by retrofitting to the FILMTEC BW30FR-365 element. In either case DUPONT FILMTEC BW30FR-365 elements can reduce the operating costs in most biofouling cases by lowering membrane fouling, reducing average system operating pressure, and extending membrane life.</p>
<h5><strong>Operating Limits:</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Operating Pressure 600 psig (41 bar)</li>
<li>Maximum Pressure Drop 15 psig (1.0 bar)</li>
<li>pH Range, Continuous Operation 2 &#8211; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 13</li>
<li>Maximum Feed Flow 70 gpm (16 m<sup>3</sup>/h)</li>
<li>Maximum Feed Silt Density Index SDI 5</li>
<li>Free Chlorine Tolerance&lt;0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Potable and non-potable water applications</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC BW30FR-365 Membrane" href="https://www.pureaqua.com/content/pdf/DUPONT-filmtec-bw30fr-365-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC BW30FR-365 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC NF270-400 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-nf270-400-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:12 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-nf270-400-membrane/</guid>

					<description><![CDATA[The DUPONT FILMTEC NF270-400 element is designed to remove a high percentage of TOC and THM precursors while having a medium to high salt passage and medium hardness passage. It is an ideal element for surface and groundwater applications where good organic removal is desired with partial softening in order to maintain a minimum level [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The DUPONT FILMTEC NF270-400 element is designed to remove a high percentage of TOC and THM precursors while having a medium to high salt passage and medium hardness passage. It is an ideal element for surface and groundwater applications where good organic removal is desired with partial softening in order to maintain a minimum level of hardness for organoleptic properties and preservation of distribution networks. The high active area membrane combined with low net driving pressure of the membrane allows the removal of these compounds at low operating pressure.</p>
<h4 align="justify"><strong>Advantages</strong></h4>
<ul>
<li>Good organic (NOM) removal</li>
<li>Partial softening preserves water character</li>
<li>High flux results in high yields</li>
<li>Filmtec performance and quality</li>
</ul>
<h4 align="justify"><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4 align="justify"><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4 align="justify"><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).</li>
<li>Avoid permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="table-center" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;" rowspan="2"><strong>Product</strong></th>
<th style="text-align: center;" rowspan="2"><strong>GMID</strong></th>
<th style="text-align: center;" colspan="2"><strong>Nominal Active Surface Area ft<sup>2</sup>(m<sup>2</sup>)</strong></th>
<th style="text-align: center;" colspan="2"><strong>Product Water Flow Rate gpd (m<sup>3</sup>/d)</strong></th>
<th style="text-align: center;" rowspan="2"><strong>Stabilized Salt Rejection (%)</strong></th>
</tr>
<tr>
<th style="text-align: center;"><strong>ft<sup>2</sup></strong></th>
<th style="text-align: center;"><strong>(m<sup>2</sup>)</strong></th>
<th style="text-align: center;"><strong>gpd</strong></th>
<th style="text-align: center;"><strong>(m<sup>3</sup>/d)</strong></th>
</tr>
<tr>
<td style="text-align: center;">NF270-400</td>
<td style="text-align: center;">148822</td>
<td style="text-align: center;">400</td>
<td style="text-align: center;">(37)</td>
<td style="text-align: center;">12,500</td>
<td style="text-align: center;">(47.3)</td>
<td style="text-align: center;">97</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<ul>
<li>The DUPONT FILMTEC&trade; NF270-400 element is a high area, high productivity element designed to remove a high percentage of TOC and THM precursors while having a medium to high salt passage; medium hardness passage.</li>
<li>The DUPONT FILMTEC NF270-400 element is an ideal element for surface and ground water applications where good organic removal is desired with partial softening in order to maintain a minimum level of hardness for organoleptic properties and preservation of distribution networks.</li>
<li>The high active area membrane combined with low net driving pressure of the membrane allows the removal of these compounds at low operating pressure.</li>
</ul>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Operating Pressure 600 psig (41 bar)</li>
<li>Maximum Pressure Drop 15 psig (1.0 bar)</li>
<li>pH Range, Continuous Operation 3 &#8211; 10</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 12</li>
<li>Maximum Feed Flow 70 gpm (15.9 m<sup>3</sup>/hr)</li>
<li>Maximum Feed Silt Density Index SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Production of municipal drinking water</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC NF270-400 Membrane" href="https://www.pureaqua.com/content/pdf/DUPONT-filmtec-nf270-400-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC NF270-400 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC NF270-2540 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-nf270-2540-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:10 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-nf270-2540-membrane/</guid>

					<description><![CDATA[The DUPONT FILMTEC NF270 membrane elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage.&#160;The DUPONT FILMTEC NF270 membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening. Advantages: Good organic (NOM) [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">The DUPONT FILMTEC NF270 membrane elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage.&nbsp;The DUPONT FILMTEC NF270 membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening.</p>
<h4 align="justify"><strong>Advantages:</strong></h4>
<ul>
<li>Good organic (NOM) removal</li>
<li>Partial softening preserves water character</li>
<li>High flux results in high yields</li>
<li>Filmtec performance and quality</li>
</ul>
<h4 align="justify"><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4 align="justify"><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4 align="justify"><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 30 psi (2.1 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="table-center" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;" rowspan="2"><strong>Product</strong></th>
<th style="text-align: center;" rowspan="2"><strong>Part Number</strong></th>
<th style="text-align: center;" colspan="2"><strong>Active Area</strong></th>
<th style="text-align: center;" colspan="2"><strong>Applied Pressure</strong></th>
<th style="text-align: center;" colspan="2"><strong>Permeate Flow Rate</strong></th>
<th style="text-align: center;" rowspan="2"><strong>Stabilized Salt Rejection (%)</strong></th>
</tr>
<tr>
<td style="text-align: center;"><strong>ft<sup>2</sup></strong></td>
<td style="text-align: center;"><strong>(m<sup>2</sup>)</strong></td>
<td style="text-align: center;"><strong>psig</strong></td>
<td style="text-align: center;"><strong>(bar)</strong></td>
<td style="text-align: center;"><strong>GPD</strong></td>
<td style="text-align: center;"><strong>(m<sup>3</sup>/d)</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>NF270-2540</strong></td>
<td style="text-align: center;">149986</td>
<td style="text-align: center;">28</td>
<td style="text-align: center;">(2.6)</td>
<td style="text-align: center;">70</td>
<td style="text-align: center;">(4.8)</td>
<td style="text-align: center;">850</td>
<td style="text-align: center;">(3.2)</td>
<td style="text-align: center;">97.0</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">The DUPONT FILMTEC&trade; NF270 membrane elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage. The FILMTEC NF270 membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening.</p>
<h5 align="justify"><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Operating Pressure 600 psi (41 bar)</li>
<li>Maximum Feed Flow Rate: 4040 elements &#8211; 16 gpm (3.6 m<sup>3</sup>/hr)</li>
<li>Maximum Feed Flow Rate: 2540 elements &#8211; 6 gpm (1.4 m<sup>3</sup>/hr)</li>
<li>Maximum Pressure Drop: Tape wrapped 13 psig (0.9 bar)</li>
<li>Maximum Pressure Drop: Fiberglassed 15 psig (1.0 bar)</li>
<li>pH Range, Continuous Operation 2 &#8211; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 12</li>
<li>Maximum Feed Silt Density Index SDI 5</li>
<li>Free Chlorine Tolerance 0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Production of drinking water</li>
</ul></div>
<div align="justify">
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC NF270-2540 Membrane" href="../../../../content/pdf/dupont-dow-filmtec-nf270-2540-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC NF270-2540 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT FILMTEC LP-4040 Membrane</title>
		<link>https://aquacomponents.sa/product/dupont-filmtec-lp-4040-membrane/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:07 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-filmtec-lp-4040-membrane/</guid>

					<description><![CDATA[DUPONT FILMTEC LP-4040 delivers high quality water at low pressure operation and can replace many &#8220;first generation&#8221; low pressure membrane elements and purify more water in many older systems, especially on cold water feeds. The Filmtec LP-4040 elements feature a 34 mil feed spacer to lessen the impact of fouling and may be cleaned over [&#8230;]]]></description>
										<content:encoded><![CDATA[<p align="justify">DUPONT FILMTEC LP-4040 delivers high quality water at low pressure operation and can replace many &#8220;first generation&#8221; low pressure membrane elements and purify more water in many older systems, especially on cold water feeds. The Filmtec LP-4040 elements feature a 34 mil feed spacer to lessen the impact of fouling and may be cleaned over a wide pH range (pH 1-13) for the most effective cleaning.</p>
<h4><strong>Advantages</strong></h4>
<ul>
<li>High rejection results in excellent water quality</li>
<li>Low energy usage reduces power consumption and costs</li>
<li>durable with good cleanability for long element life</li>
<li>Filmtec Performance and quality</li>
</ul>
<h4><strong>Important Information</strong></h4>
<p align="justify">Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.</p>
<p align="justify">Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.</p>
<p align="justify">Please refer to the application information literature entitled &ldquo;Start-Up Sequence&rdquo; (Form No. 609-02077) for more information.</p>
<h4><strong>Operation Guidelines</strong></h4>
<p align="justify">Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutDUPONTn, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:</p>
<ul>
<li>Feed pressure should be increased gradually over a 30-60 second time frame.</li>
<li>Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.</li>
<li>Permeate obtained from first hour of operation should be discarded.</li>
</ul>
<h4><strong>General Information</strong></h4>
<ul>
<li>Keep elements moist at all times after initial wetting.</li>
<li>If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.</li>
<li>To prevent biological growth during prolonged system shutDUPONTns, it is recommended that membrane elements be immersed in a preservative solution.</li>
<li>The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.</li>
<li>Maximum pressure drop across an entire pressure vessel (housing) is 30 psi (2.1 bar).</li>
<li>Avoid static permeate-side backpressure at all times.</li>
</ul>
<div>
<div class="tabtitle" id="custom-specifications">Models</div>
<h5><strong>Specifications</strong></h5>
<div style="overflow-x: auto;">
<table class="tableCenter" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th style="text-align: center;">Product</th>
<th style="text-align: center;">Part number</th>
<th style="text-align: center;">Feed Spacer Thickness (mil)</th>
<th style="text-align: center;">Permeate Flow Rate gpd (m<sup>3</sup>/d)</th>
<th style="text-align: center;">Stabilized Salt Rejection (%)</th>
</tr>
<tr>
<th style="text-align: center;">LP-4040</th>
<td style="text-align: center;">212819</td>
<td style="text-align: center;">34</td>
<td style="text-align: center;">2,900 (11.0)</td>
<td style="text-align: center;">99.2</td>
</tr>
</tbody>
</table></div>
</p></div>
<div>
<div class="tabtitle" id="custom-features">Features</div>
<p align="justify">A complete range of DUPONT FILMTEC&trade; 4040-size elements is available to meet a wide variety of customer needs for commercial applications, from the highest purity water to the lowest total system costs.</p>
<ul>
<li>DUPONT FILMTEC XLE-4040 is the most productive, lowest pressure RO membrane available, delivering the lowest total system cost.</li>
<li>DUPONT FILMTEC LP-4040 delivers high quality water at low pressure operation. LP-4040 replaces many &ldquo;first generation&rdquo; low pressure membrane elements and will purify more water in many older systems, especially on cold water feeds.</li>
<li>DUPONT FILMTEC TW30-4040 is the industry standard for reliable operation and production of the highest quality water.</li>
</ul>
<p align="justify">Tape-wrapped elements are built with the same high quality membranes and materials of construction as industrial elements, except for the hard outershell, and are more economical for commercial systems with one or two elements per housing.</p>
<h5><strong>Operating Limits</strong></h5>
<ul>
<li>Membrane Type Polyamide Thin-Film Composite</li>
<li>Maximum Operating Temperature 113&deg;F (45&deg;C)</li>
<li>Maximum Operating Pressure 600 psig (41 bar)</li>
<li>Maximum Feed Flow Rate 14 gpm (3.2 m<sup>3</sup>/hr)</li>
<li>Maximum Pressure Drop 13 psig (0.9 bar)</li>
<li>pH Range, Continuous Operation 2 &#8211; 11</li>
<li>pH Range, Short-Term Cleaning (30 min.) 1 &#8211; 13</li>
<li>Maximum Feed Silt Density Index (SDI) SDI 5</li>
<li>Free Chlorine Tolerance &lt;0.1 ppm</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-usage">Applications</div>
<ul>
<li>Commercial water demineralization</li>
</ul></div>
<div>
<div class="tabtitle" id="custom-documents">Docs</div>
<div class="hl-custom-tab-content document"><a title="DUPONT FILMTEC LP-4040 Membrane" href="https://www.pureaqua.com/content/pdf/DUPONT-filmtec-lp-4040-membrane.pdf" target="_blank" rel="noopener">DUPONT FILMTEC LP-4040 Membrane</a></div>
</p></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUPONT ??IntegraTec XP 51 IG</title>
		<link>https://aquacomponents.sa/product/dupont-integratec-xp-51-ig/</link>
		
		<dc:creator><![CDATA[aqua@2025]]></dc:creator>
		<pubDate>Thu, 13 Mar 2025 12:54:06 +0000</pubDate>
				<guid isPermaLink="false">https://aquacomponents.sa/product/dupont-integratec-xp-51-ig/</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
